Installation Guide
(*) Based on first wire rope layer closest to drum.
Capacity decreases by approximately 10% for each successive layer of wire rope wrapped onto the drum.
Load Speed Current (amps)
lbs. kg FPM MPM 115 V 208 V 230 V
0 0 10.5 3.2 6.6 2.8 3.3
500 227 10.5 3.2 7.1 3.0 3.6
1000 454 10.5 3.2 7.8 3.5 3.9
1500 680 10.3 3.1 9.7 4.7 4.9
2000 907 10.0 3.0 11.5 6.3 5.7
PERFORMANCE*
3
2
This electric winch is designed for multipurpose hauling and pulling operations. Unit
can be mounted to a support beam, wall or other structurally suitable anchoring point
in a horizontal or vertical position. Winch is equipped with a capacitor start induction
run AC motor, permanently lubricated gearbox, drag brake, reversing switch, galva-
nized wire rope and forged hook. Unit can be wired to operate on 115/208-230 VAC
60 Hz, single phase. This unit is not to be used as a hoist for lifting, supporting, or
transporting people, or for handling loads over where people could be present.
IMPORTANT: For your own safety and that of others, this equipment
must be used as recommended by the manufacturer. Failure to follow these
recommendations could endanger your life. See general safety information section.
Please read and understand this Owner’s Manual prior to installing and using your
winch. Pay particular attention to the General Safety Information. Your winch is a very
powerful machine. If used unsafely or improperly, there is a possibility that property
damage or personal injury can result. We have included several features in this winch
to minimize this possibility; however, your safety ultimately depends on your caution
when using this product.
Throughout this manual, you will find notations with the following headings:
Indicates an imminently hazardous situation which,
if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. This
notation is also used to alert against unsafe practices.
The following symbols on the product and in the Owner's manual are used:
Note: Indicates additional information in the installation and operation
procedures of your winch.
Please Note: This winch is not designed to be used in industrial or hoisting
applications and Superwinch does not warrant it to be suitable for such use.
Superwinch manufactures a separate line of winches for industrial/commercial
use. Please contact our Customer Service Department for further information.
Note: The electrical requirements of the winch you have purchased:
115/208-230 Volt 60Hz single phase
Congratulations on your choice!
INTRODUCTION
Description Quantity
Winch assembly with wire rope 1
Reversing switch 1
Handsaver 1
Hex head cap screws, 3/8-16 x 1
1
/
2
Hex nuts, 3/8-16
Lockwashers, 3/8
Flat washers, 3/8 4 ea.
UNPACKING
Cartons should be handled with care to avoid damage from dropping, etc. After
unpacking unit, inspect carefully for any damage that may have occurred during
transit. Check for loose, damaged or missing parts.
Do not use this winch outdoors or in a corrosive or
explosive environment.
WARNING
!
CAUTION
!
DANGER
!
Read Owner's
Manual
Always Use
Handsaver
Keep clear of winch,
wire rope and hook
while operating
Never use winch
to lift or move
people
Never use
winch to hold
loads in place
WARNING
!
AC2000
Load Speed Current (amps)
lbs. kg FPM MPM 115 V 208 V 230 V
0 0 10.5 3.2 7.5 3.2 3.8
500 227 10.5 3.2 7.8 3.3 3.9
1000 454 10.5 3.2 8.7 4.0 4.4
1500 680 10.5 3.2 10.0 4.8 5.0
2000 907 10.3 3.1 11.4 6.2 5.7
2500 1134 10.3 3.1 13.5 7.4 6.8
3000 1361 10.3 3.1 16.5 9.1 8.3
AC3000
SPECIFICATIONS
AC2000 AC3000
Motor 0.75 HP, 3450 RPM 1.0 HP, 3450 RPM
Power Required 115/208-230V, 60 Hz, single phase 115/208-230V, 60 Hz, single phase
Gear Ratio 253:1 253:1
Wire Rope 5/16” x 100’ (7.9mm x 30.5m) 5/16” x 100’ (7.9mm x 30.5m)
Duty Cycle
• Pulling at working load 20 minutes on, 1/2 hour off 20 minutes on, 1/2 hour off
• Against brake 5 minutes on, 1/2 hour off 5 minutes on, 1/2 hour off
Working Load 2000 lbs. 3000 lbs.
* Based on first layer performance