Connecting additional electrical equipment
When working on electrical systems there is
a risk of danger to life due to electrocution.
The connection of additional electrical equipment
must only be carried out by a qualified electrician.
Before opening the protective cover always dis-
connect the equipment from the mains power supply
and check that the system is free of voltage.
Accessories from other manufacturers may
result in malfunctions or damage to property.
Use only original accessories. A separate source
voltage at the screwtype terminal for the external
switch will result in a short circuit and will destroy
the door operator’s electronics.
Do not connect any separate source voltages to the
terminal for the external switch. The terminals are
potential-free contacts.
Key
1 = Motherboard
2 = Infrared-photocell barrier (optional)
3 = External switch (optional)
Connecting conditions for connecting an
infrared photocell barrier:
Voltage: = + 12 V
Curent: = max. 150 mA
Type: = NC
If the external buttons are not connected
properly, the operational safety of the
equipment is at risk.
Always mount the internal button, programming
button, etc.:
outside the reach of movable parts
within visibility of the door
at a height of at least 1.5 metres
GND
+ 12V
COM
OUT
GND
+ 12V
IR
GND
+ 12V
1
2
3
Ext. switch (type: NO)
GND
Pass Door contact
NOTE: If pass door contact assembled, remove jumper