User manual
58
EN
Automatic closing time setting
4. Press „+“ and select
the required closing time:
1 = 30 sec.
2 = 60 sec.
3 = 90 sec.
4 = 120 sec.
5. Press „P“ in order
to store the setting.
5 = 150 sec.
6 = 180 sec.
7 = 210 sec.
8 = 240 sec.
(maximum)
After a period of time in use, regularly
check to see whether the door is level when
opening/closing, and whether the spring has
enough force to raise the door.
Add a suitable amount of lubricant to all
moving parts regularly.
1. Press „+“ (press several
times if necessary) until
„8“ is displayed.
2000 cycle alarm setting
2. Press „P“,
the display is „0“.
(0 = off = factory setting)
3. Press „+“,
the display is „1“.
(1 = on)
NOTE
If this function is activated, after 2000 cycles the door
operator will indicate with a short whistling tone at regu-
lar intervals that door maintenance must be carried out.
To end the alarm tone
Switch the power supply off and then on again, or press
the „P“ button for the door for 5 seconds.
4. Press „P“ in order
to store the setting.
6. Conclude programming
(refer to page 59,
method 2)
or
proceed with the next
setting.
5. Conclude programming (refer to page 59, method 2) or
proceed with next setting.