User manual

55
EN
NOTE
The door operator is preset to stage 3 by the supplier.
If required (e.g. if the power level is too low) you can
subsequently adjust the power limiting setting.
If the power level is too low, the door
movement will be impaired, particularly if
the mechanical structure of the door is not
well balanced.
1. Press+“ (if necessary
press several times) until
„4“ is displayed.
Adjust power limiting as required
2. PressP“, the display
shows „7“ (stage 3).
3. Press+“ or press „-
to select the stage.
After a resetting of the power level, it is absolutely necessary to repeat the reference run for power
limiting and to conclude the programming again.
During the reference run there is a risk of injury as the door operator develops extremely strong forces.
Factory setting
4. PressP“, in order
to store the setting.
5. IMPORTANT
Repeat reference run
for power limiting
(refer to page 54).
6. Conclude programming
(refer to page 59,
method 1).
Power level
Low High