User`s manual
2-36
 X9SRi/X9SRE Motherboard Series User’s Manual
JLAN2
3
JSTBY
JCOM1
R625
MH7
MH1
MH5
41
FAN1
41
FAN2
4
1
FAN3
41
FAN4
41
FANA
JVR6
3
JVR5
1
3
JVR4
1
3
JVR3
1
3
JPB1
1
3
JPG1
1
JPL1
1
JPL2
JVR1
1
3
JVR2
1 3
JWD1
1
3
JPUSB1
1
JPME_RCV1
3
JPBIOS_RCV1
1
3
DP3
A
C
JI2C1
JI2C2
1
JOH1
1
JCF1
JL1
3-SGPIO2
1
2
7
8
3-SGPIO1
1
2
7
8
T-SGPIO1
2
7
8
T-SGPIO2
1
2
7
8
DIMM_C1
JUSB2
4
PCIX1
PCIX2
PCIX3
JPW1
1
12
24
JBT1
JPI2C1
1
5
SP1
+
PCIE6
PCIE5
PCIE4
X_BT1
JPW2
UID_LED
A
C
UID_SW
1
2
JTPM1
1
2
19
20
SAS4
SAS5 SAS6
SAS7 I-SATA2I-SATA3
I-SATA4
I-SATA5
JKBMS1
+
U8
JWF1
1
3
JTAG1
JD1
1
7
JF1
1
2
19
20
JVGA
JIPMB1
I-SATA1
I-SATA0
MAC CODE
MAC CODE
REV:1.01
Tested to Comply
With FCC Standards
FOR HOME OR OFFICE USE
DESIGNED IN USA
SAS CODE
JCOM2
1
5
6
9
JUSB45
2
7
10
JUSB67
1
2
7
JUSB89
1
2
7
10
JRK1
Pin3:PCH_DYN_SKU
Pin2:Ground
OFF:NORMAL
ON:ME IN FORCE UPDATA MODE
I-Button Header 1
Pin1:RAID_KEY_PCH
OFF:NORMAL
ON:RECOVER BIOS
UID
TPM/PORT80
JIPMB1
P1-DIMM4A
P1-DIMM4B
P1-DIMM3A
P1-DIMM3B
P1-DIMM2A
P1-DIMM2B
P1-DIMM1B
P1-DIMM1A
I-SATA5
I-SATA4
I-SATA3 I-SATA2
I-SATA1
I-SATA0
2-3 ENable
Power
Flash
KB/MOUSE
X9SRi
JPUSB1:USB Wake Up
1-2 Disable
PWRI2C
JF1
RST
ON
PWR
PWR
FF
FAIL
HDD
NIC
1
2
NIC
OH
LED
NMI
PWR
X
PWR LED
SPEAKER
1-3:
4-7:
JD1:
2-3:NMI
JWD1:Watch Dog
1-2:RST
LAN1
LAN2
JPL1/2: LAN
2-3 Disable
1-2 Enable
FAN4
VGA
COM1
USB0/1
INTRUSION
 CHASSIS
OFF: SLAVE
ON: MASTER
JCF1:Compact Flash
Compact
SAS1/SAS3
SAS0/SAS2
3-SGPIO23-SGPIO1
Connect to IPMI
USB2
USB8/9
USB4/5
USB6/7
2-3 Disable
JPB: BMC
1-2 Enable
JSTBY : Wake on Lan
COM2
1-2 Enable
2-3 Disable
JPG1: VGA
OFF:DISABLE
ON: ENABLE
I2C Bus for PCI slot
JI2C1/JI2C2
SLOT4 PCI-E 3.0 X8 (IN X16)
SLOT5 PCI-E 2.0 X4 (IN X16)
SLOT6 PCI-E 3.0 X16
SLOT3 PCI-X 133/100MHZ
SLOT1 PCI-X 133/100MHZ
SLOT2 PCI-X 133/100MHZ
CLOSE 1st
OPEN 1st
JPW2
A
C
B
IPMI Heartbeat LED (DP3)
The IPMI Heartbeat LED is located at DP3. 
When DP3 blinks, the IPMI feature is func-
tioning properly. Refer to the table on the 
right for details. Also see the layout below 
for the LED location. This is supported on 
the X9SRi-3F/X9SRE-3F only.
IPMI Heartbeat LED Indicator
LED Settings
Green: Blinking IPMI is ready for use
Rear Unit ID LED (UID LED)
The rear  Unit ID  LED  is located at  UID 
LED  on  the  backpanel.  This  LED  is  used 
in  conjunction  with  the  rear  UID  switch  to 
provide easy identication of a system that 
might be in need of service.
Rear UID LED
LED Settings
Blue: Solid UID Toggled On
A. Rear Unit ID LED
B. IPMI Heartbeat LED
C. Power LED
Onboard Power LED (DP2)
An  Onboard  Power LED  is located  at 
PWR  LED  on  the  motherboard.  When 
PWR  LED  is  on,  it  means  that  the AC 
power cable is connected, the power 
supply switch and soft switch are on, and 
the system is running. 
Onboard PWR LED (DP2)
LED Status
Status Denition 
Off System Off (Soft Switch)
On System is Running