User's Guide

3-8
Adaptec SCSI Card 39320D Users Guide for Floppy Disks (OEM)
When partitioning a disk larger than 1 GB, use the MS-DOS
Screen Message utility as you normally would. Because the
cylinder size increases to 8 MB under extended translation, the
partition size you choose must be a multiple of 8 MB. If you
request a size that is not a multiple of 8 MB, Screen Message
rounds up to the nearest whole multiple of 8 MB.
Post Display Mode(Default: Verbose) During POST, the
amount of information displayed depends on the mode. If you
change this setting, the change automatically applies to both
SCSI channels. The following modes are available:
Verbos eThe results of the SCSI bus scan are displayed, but
the results of the PCI bus scan are not displayed.
SilentNothing is displayed about POST, not even the
Adaptec banner. However, error messages are displayed if
there is a problem on the SCSI bus or SCSI devices.
DiagnosticThe PCI and SCSI bus scan results are displayed
separately. There is a pause between PCI and SCSI scans.
SCSI Controller INT 13 Support(Default: Enabled) This
option controls the state of the BIOS at POST time. The
following settings are available:
EnabledSupports INT 13 for booting from a SCSI hard disk
drive connected to the SCSI card. If you use this option, the
following options are available:
Extended INT 13 Translation for DOS Drives > 1 GB
Support Removable Disks Under INT 13 as Fixed Disks
BIOS Support for Bootable CD-ROM
Disabled:NOT ScanSet to this option if the devices on the
SCSI bus (for example, CD-ROM drives) are controlled by
software drivers and do not need the BIOS, and you do not
want the BIOS to scan the SCSI bus.
Disabled:Scan BusSet to this option if the devices on the
SCSI bus (for example, CD-ROM drives) are controlled by
software drivers and do not need the BIOS, and you do not
want the BIOS to scan the SCSI bus.
ASC-39320D UG.book Page 8 Monday, July 22, 2002 1:42 PM