SUPER X5DP8-G2/DPE-G2/DPR-8G2+/DPR-iG2+/DPi-G2 User's Manual
Thermal Fan Enable/Disable
(X5DP8-G2, X5DPE-G2,
X5DPi-G2)
JP38 allows you to enable or disable
the thermal fan. When enabled, the
fan will operate continuously. When
disabled, it will operate only when a
predefined temperature threshold
has been exceeded. See the table
on the right for jumper settings.
Jumper
Position
Open
Closed
Definition
Disabled
Enabled
Thermal Fan
Enable/Disable
Jumper Settings (JP38)
SCSI Termination Enable/
Disable (X5DP8-G2, X5DPR-
8G2+)
Jumpers JPA1 and JPA2 allow you
to enable or disable termination for
the individual SCSI channels.
Jumper JPA1 controls SCSI channel
A and JPA2 controls SCSI channel
B. The normal (default) setting is
open to enable (teminate) both SCSI
channels. If you wish to connect
external SCSI devices, you should
disable termination for the
channnel(s) you will be connecting
them to. See the table on the right
for jumper settings.
Jumper
Position
Open
Closed
Definition
Enabled
Disabled
SCSI Channel Termination
Enable/Disable
Jumper Settings
(JPA1, JPA2)
Watch Dog Enable/Disable
The Watch Dog jumper (located on
JP37) allows you to enableor dis-
able the Watch Dog feature. The
default position is open to disable
the Watch Dog timer. When en-
abled, Watch Dog can reboot your
PC if an application is "hung up" or
the system goes down. See the
table on the right for jumper set-
tings.
Jumper
Position
Open
Closed
Definition
Disabled
Enabled
Watch Dog Timer Enable/
Disable Jumper Settings
(JP37)