User`s manual

2-6
S
UPERSERVER 6035B-8R+ User's Manual
Installing the Server into the Rack
Locate the front and rear brackets that on both ends of the outer chassis rail. These
brackets sit perpendicular to the rail and are used to attached the rail to the rack.
Secure the front bracket to the rack with two screws and the rear bracket to the
rack with four screws using the appropriate screws and washers included in the
hardware kit (see Figure 2-3). You may need to adjust the rail to match the depth
of the rack. Repeat the same steps to install the other outer rail to the rack.
You are now ready to install the server into the rack. Slide the chassis into the
rack as shown in Figure 2-4. The chassis may not slide into the rack smoothly or
easily when installed the fi rst time. Some adjustment to the slide assemblies might
be needed for easier installation.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". You'll need to release the safety taps on both sides of the
chassis in order to completely remove the chassis out of the rack.
Figure 2-3. Assembling the Rack Rails
Screws
Screws
Front Bracket
Rear Bracket