Chapter 2: Server Installation
2-5
Installing the Chassis Rails
Position one of the chassis rail sections you just removed along the side of the
6035B-8R+. Note that the two chassis rails are left/right speciļ¬ c. Locate the numer-
ous rail tabs on each side of the chassis and the corresponding holes on each of
the chassis rails. Note that the holes are elongated with one end of the hole larger
than the other. Align the larger end of each hole with its corresponding tab. With
all holes and tabs aligned, position the rail onto the side of the chassis (see Figure
2-2). Once a rail is positioned on the chassis, pull it forward until the rail tabs lock
in the small ends of the corresponding holes. Then secure the rail to the chassis
with the screws included in the harware kit. Repeat the above steps to install the
other rail on the chassis.
Locking Tabs: As mentioned, both chassis rails have locking tabs, which serve to
lock the server into place when installed and pushed fully into the rack (its normal
position).
Figure 2-2. Installing Chassis Rails