2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 6035B-8R+ into a
rack unit. If the 6035B-8R+ has already been mounted into a rack, you can skip
ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which
may mean the assembly procedure will differ slightly. The following is a guideline for
installing the 6035B-8R+ into a rack with the rack rails provided. You should also
refer to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6035B-
8R+. Each of these assemblies consist of two sections: an inner chassis rail that
secures to the chassis (A) and an outer rack rail that secures directly to the rack
itself (B). All screws and hardware mentioned in the installation steps should be
included in the hardware kit.
To remove the chassis rail (A), pull it out as far as possible - you should hear a
"click" sound as a locking tab emerges from inside the rail assembly and locks the
inner rail. Then depress the locking tab to pull the inner rail completely out. Do
this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
A
B
Locking Tab