SUPER SUPERSERVER 1027GR-TRF 1027GR-TRFT USER’S MANUAL Revision 1.
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com. Super Micro Computer, Inc.
Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 1027GRTRF/1027GR-TRFT. Installation and maintenance should be performed by experienced technicians only. The 1027GR-TRF/1027GR-TRFT is based on the SC118GQ-R1800B 1U rackmount server chassis and the Super X9DRG-HF/X9DRG-HTF serverboard.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X9DRG-HF/X9DRG-HTF serverboard, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard. Chapter 6: Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC118GQ-R1800B 1U rackmount server chassis.
Preface Notes v
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Table of Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features ..................................................................................... 1-2 Processors ...................................................................................................... 1-2 Memory .......................................................
Table of Contents Chapter 3 System Interface 3-1 Overview ......................................................................................................... 3-1 3-2 Control Panel Buttons ..................................................................................... 3-1 Reset ............................................................................................................... 3-1 Power ................................................................................................
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual 5-11 SATA Ports .................................................................................................... 5-24 5-12 Installing Software ......................................................................................... 5-25 Supero Doctor III ........................................................................................... 5-26 Chapter 6 Advanced Chassis Setup 6-1 Static-Sensitive Devices .......................................
Chapter 1: Introduction Chapter 1 Introduction 1-1 Overview The SuperServer 1027GR-TRF/1027GR-TRFT series is a GPU-optimized server comprised of two main subsystems: the SC118GQ-R1800B 1U server chassis and the X9DRG-HF/X9DRG-HTF serverboard. Please refer to our web site for information on operating systems that have been certified for use with the system (www. supermicro.com).
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Note: For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user’s manual for your server. • Supermicro product manuals: http://www.supermicro.com/support/manuals/ • Product drivers and utilities: ftp://ftp.supermicro.com • Product safety info: http://super-dev/about/policies/safety_information.cfm • If you have any questions, please contact our support team at: support@supermicro.
Chapter 1: Introduction Onboard Controllers/Ports The color-coded I/O ports include one COM port (an additional COM header is located on the serverboard), a VGA (monitor) port, two USB 2.0 ports, two Gb Ethernet LAN ports (two 10 Gb ports on the X9DRG-HTF) and one dedicated IPMI LAN port. IPMI IPMI (Intelligent Platform Management Interface) is a hardware-level interface specification that provides remote access, monitoring and administration for Supermicro server platforms.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual 1-4 GPU Subsystem The 1027GR-TRF/1027GR-TRFT server represents one of Supermicro's massively parallel processing multiple-GPU servers, with support for up to three NVIDIA® Fermi™ or Kepler™ GPUs, which place this system at the forefront of today's GPU computing solutions. Please refer to the NVIDIA web site (www.nvidia.com) for details on Fermi GPUs.
Chapter 1: Introduction Figure 1-1. Intel C602 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. #0-4 #0-3 #0-2 #0-1 #3 PCI-E X16 G3 PCI-E X16 G3 SATA2/ SAS1 3.0 Gb/S SATA2 3.0 Gb/S SATA Ports #0~5 SATA3 6.0 Gb/S USB 2.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual 1-5 Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V.
Chapter 2: Server Installation Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your system up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display Units. 2-4 Warnings and Precautions Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. • • • • In single rack installation, stabilizers should be attached to the rack.
Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual 2-4 Installing the System into a Rack This section provides information on installing the SC118GQ chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using. Note: This rail will fit a rack between 26" and 33.5" deep.
Chapter 2: Server Installation Installing the Inner Rail Extensions The SC118GQ chassis includes a set of inner rack rails in two sections: inner rails (A) and inner rail extensions (B). The inner rails are preattached and do not interfere with normal use of the chassis if you decide not to install to a server rack. Attaching the inner rail extensions to to the inner rails stabilizes the chassis within the rack. Installing the Inner Rail Extensions 1.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Assembling the Outer Rails Each outer rail is in two sections that must be assembled before mounting on to the rack. Assembling the Outer Rails 1. Identify the left and right outer rails by examining the ends, which bend outward. 2. Slide the front section of the outer rail (A), into the rear section of the outer rail (B). Figure 2-3.
Chapter 2: Server Installation Installing the Outer Rails onto the Rack Outer Rail Installation 1. Adjust the outer rails to the proper length so that the outer rail fits snugly within the rack. 2. Align the holes on the front of the outer rail, with the holes on the front of the rack (C) and secure with the screws provided. 3. Align the holes on the rear of the outer rail to the holes on the rack (D) and secure with the screws provided. 4. Repeat the procedure with the second outer rail assembly.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Installing and Removing the Chassis From a Rack Installation into a Rack 1. Slide the inner rail extensions into the front of the outer rails. 2. Push the chassis backward into the rack until it clicks into the locked postion. Removing the Chassis From a Rack 1. Press the outer rail latch to release the chassis. 2. Carefully slide the chassis forward, off the outer rails and out of the chassis. Figure 2-5. Chassis Installation Figure 2-6.
Chapter 2: Server Installation Installing the Server into a Telco Rack Optional brackets are needed to install the server to a telco (open type) rack. To install the server into a Telco type rack, use the two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Notes 2-10
Chapter 3: System Interface Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components. There are also two buttons on the chassis control panel. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual 3-3 Control Panel LEDs The two control panels are located on the front of the SC118GQ chassis. Each control panel has six LEDs. These LEDs provide critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any action that may be required.. Overheat/Fan Fail/UID LED When this LED flashes it indicates a fan failure.
Chapter 3: System Interface HDD This light indicates SATA and/or peripheral drive activity when flashing. Power Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating. 3-4 • • Drive Carrier LEDs Green: Each hard drive carrier (for use with SATA drives) has a green LED. When illuminated, this green LED (on the front of the SATA drive carrier) indicates drive activity.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Notes 3-4
Chapter 4: Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems 4-1 About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
Warning Statements for AC Systems . ﺗﺤﺬﻳﺮ!ﻫﺬﺍ ﺍﻟﺮﻣﺰ ﻳﻌﻨﻲ ﺧﻄﺮ ﺍﻧﻚ ﻓﻲ ﺣﺎﻟﺔ ﻳﻤﻜﻦ ﺃﻥ ﺗﺘﺴﺒﺐ ﻓﻲ ﺍﺻﺎﺑﺔ ﺟﺴﺪﻳﺔ ﻛﻦ ﻋﻠﻰ ﻋﻠﻢ ﺑﺎﻟﻤﺨﺎﻁﺮ ﺍﻟﻨﺎﺟﻤﺔ ﻋﻦ ﺍﻟﺪﻭﺍﺋﺮ،ﻗﺒﻞ ﺃﻥ ﺗﻌﻤﻞ ﻋﻠﻰ ﺃﻱ ﻣﻌﺪﺍﺕ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻭﻛﻦ ﻋﻠﻰ ﺩﺭﺍﻳﺔ ﺑﺎﻟﻤﻤﺎﺭﺳﺎﺕ ﺍﻟﻮﻗﺎﺋﻴﺔ ﻟﻤﻨﻊ ﻭﻗﻮﻉ ﺃﻱ ﺣﻮﺍﺩﺙ ﺍﺳﺘﺨﺪﻡ ﺭﻗﻢ ﺍﻟﺒﻴﺎﻥ ﺍﻟﻤﻨﺼﻮﺹ ﻓﻲ ﻧﻬﺎﻳﺔ ﻛﻞ ﺗﺤﺬﻳﺮ ﻟﻠﻌﺜﻮﺭ ﺗﺮﺟﻤﺘﻬﺎ 안전을 위한 주의사항 경고! 이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확인하시고 사전에 사고를 방지할 수 있도록 표준 작업절차를 준수해 주시기 바랍니다.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché de toutes les sources de puissance ainsi que de son cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour installer ou enlever des composants de systéme.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Equipment Installation Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、交換、 またはサービスを許可 されています。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal gestattet werden.
Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. (This warning does not apply to workstations).
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual אזור עם גישה מוגבלת !אזהרה הגישה ניתנת בעזרת.יש להתקין את היחידה באזורים שיש בהם הגבלת גישה .(' מנעול וכד,כלי אבטחה בלבד )מפתח . ﺗﻢ ﺗﺨﺼﻴﺺ ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ ﻟﺘﺮﻛﻴﺒﻬﺎ ﻓﻲ ﻣﻨﺎﻁﻖ ﻣﺤﻈﻮﺭﺓ ،ﻳﻤﻜﻦ ﺍﻟﻮﺻﻮﻝ ﺇﻟﻰ ﻣﻨﻄﻘﺔ ﻣﺤﻈﻮﺭﺓ ﻓﻘﻂ ﻣﻦ ﺧﻼﻝ ﺍﺳﺘﺨﺪﺍﻡ ﺃﺩﺍﺓ ﺧﺎﺻﺔ ﻗﻔﻞ ﻭﻣﻔﺘﺎﺡ ﺃﻭ ﺃﻱ ﻭﺳﻴﻠﺔ ﺃﺧﺮﻯ ﻟﻼﻷﻣﺎﻥ 경고! 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다. 특수도구, 잠금 장치 및 키, 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다.
Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニットは複数の電源装置が接続されている場合があります。 ユニットの電源を切るためには、すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben.
Chapter 4: Warning Statements for AC Systems .ﻗﺪ ﻳﻜﻮﻥ ﻟﻬﺬﺍ ﺍﻟﺠﻬﺎﺯ ﻋﺪﺓ ﺍﺗﺼﺎﻻﺕ ﺑﻮﺣﺪﺍﺕ ﺍﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ ﻳﺠﺐ ﺇﺯﺍﻟﺔ ﻛﺎﻓﺔ ﺍﻻﺗﺼﺎﻻﺕ ﻟﻌﺰﻝ ﺍﻟﻮﺣﺪﺓ ﻋﻦ ﺍﻟﻜﻬﺮﺑﺎء 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을 차단하기 위해서는 모든 연결 단자를 제거해야만 합니다. Waarschuwing Deze eenheid kan meer dan één stroomtoevoeraansluiting bevatten. Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken. Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual מתח בפנל האחורי !אזהרה יש להיזהר במהלך.קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת .העבודה ﻫﻨﺎﻙ ﺧﻄﺮ ﻣﻦ ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ ﺃﻭﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ ﺍﻟﻠﻮﺣﺔ ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ ﺍﻟﻨﻈﺎﻡ ﻳﻌﻤﻞ ﻛﻦ ﺣﺬﺭﺍ ﻋﻨﺪ ﺧﺪﻣﺔ ﻫﺬﺍ ﺍﻟﺠﻬﺎﺯ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is. Voorzichtigheid is geboden tijdens het onderhoud.
Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. תיאום חוקי החשמל הארצי !אזהרה .התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים ﺗﺮﻛﻴﺐ ﺍﻟﻤﻌﺪﺍﺕ ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ ﻳﺠﺐ ﺃﻥ ﻳﻤﺘﺜﻞ ﻟﻠﻘﻮﺍﻧﻴﻦ ﺍﻟﻤﺤﻠﻴﺔ ﻭﺍﻟﻮﻁﻨﻴﺔ ﺍﻟﻤﺘﻌﻠﻘﺔ ﺑﺎﻟﻜﻬﺮﺑﺎء 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. סילוק המוצר !אזהרה .
Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Power Cable and AC Adapter Warning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only.
Chapter 4: Warning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Notes 4-20
Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install the X9DRG-HF/X9DRG-HTF serverboard into the chassis, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Unpacking The serverboard is shipped in antistatic packaging to avoid electrical static discharge. When unpacking the board, make sure the person handling it is static protected. 5-2 Serverboard Installation This section explains the first step of physically mounting the X9DRG-HF/X9DRGHTF into the SC118GQ chassis. Following the steps in the order given will eliminate the most common problems encountered in such an installation.
Chapter 5: Advanced Serverboard Setup 5-3 Connecting Cables Now that the serverboard is installed, the next step is to connect the cables to the board. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The ribbon cables used to transfer data from the peripheral devices have been carefully routed to prevent them from blocking the flow of cooling air that moves through the system from front to back.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Figure 5-1. Control Panel Header Pins 20 19 Ground NMI x (Key) x (Key) Power On LED 3.3V HDD LED FP UID/3.3V Stby NIC1 LED (Link) NIC1 LED (Activity) NIC2 LED (Link) NIC2 LED (Activity) OH/Fan Fail/PWR Fail/UID LED Blue LED (UID Cathode) PWR Fail LED 3.3V Ground Reset (Button) Ground Power (Button) 2 5-4 1 I/O Ports The I/O ports are color coded in conformance with the PC 99 specification.
Chapter 5: Advanced Serverboard Setup 5-5 Installing the Processor and Heatsink Warning: Avoid placing direct pressure to the top of the processor package. Always remove the power cord first before adding, removing or changing any hardware components. Notes: • Always connect the power cord last and always remove it before adding, removing or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heatsink.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual 3. With the lever labeled 'Close 1st' fully retracted, gently push down on the 'Open 1st' lever to open the load plate. Lift the load plate to open it completely. WA R OP EN NI NG ! 1st Gently push down to pop the load plate open. 4. Using your thumb and the index finger, remove the 'WARNING' plastic cap from the socket. 5. Use your thumb and index finger to hold the CPU by its edges.
Chapter 5: Advanced Serverboard Setup Warning: You can only install the CPU to the socket in one direction. Make sure that the CPU is properly inserted into the socket before closing the load plate. If it doesn't close properly, do not force it as it may damage your CPU. Instead, open the load plate again and double-check that the CPU is aligned properly. 7. With the CPU in the socket, inspect the four corners of the CPU to make sure that they are flush Gently close the load plate. with the socket. 8.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Installing a CPU Heatsink 1. Remove power from the system and unplug the AC power cord from the power supply. 2. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied. 3. Place the heatsink on top of the SNK-P0047PS (CPU1) CPU so that the four mounting holes are aligned with those on the (preinstalled) heatsink retention mechanism. 4. Screw in two diagonal screws until just snug.
Chapter 5: Advanced Serverboard Setup 5-6 Installing Memory Warning: Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Memory Support The X9DRG-HF/X9DRG-HTF supports up to 256 GB of registered ECC DDR31600/1333/1066/800 MHz RDIMMs in 8 DIMM slots. See the following tables for memory installation. Notes: Memory speed support is dependent on the type of CPU used on the board. Installing Memory Modules 1.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Processor/DIMM Population Configurations For memory to work properly, follow the tables below for memory installation. • For memory to operate properly, please install DIMMs in pairs (have an even number of DIMMs installed). • All channels in a system will run at the fastest common frequency.
Chapter 5: Advanced Serverboard Setup 5-6 Expansion Cards In addition to offering support for three GPU cards, the 1027GR-TRF/1027GR-TRFT supports one low-profile PCI-Express 3.0 x8 expansion card (in x16 slot). A riser card is required to support expansion cards. Refer to Chapter 6 for instructions on installing an expansion card in the system..
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual 5-7 Serverboard Details Figure 5-5. X9DRG-HF/X9DRG-HTF Layout Use SNK-P0047PS Use SNK-P0047PSC Notes " " indicates the location of Pin 1. The X9DRG-HTF supports two X540-based 10G LAN ports, the X9DRG-HF supports two I350-based 1G LAN ports.
Chapter 5: Advanced Serverboard Setup X9DRG-HF/X9DRG-HTF Quick Reference Jumper Description Default Setting JBT1 Clear CMOS See Section 5-9 JBR1 ME Recovery Pins 2-3 (Normal) JPB1 BMC Enable/Disable Pins 1-2 (Enabled) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPL1 LAN1/LAN2 Enable/Disable Pins 1-2 (Enabled) JPME1 Manufacture Mode Pins 1-2 (Normal) JWD Watch Dog Timer Enable/Disable Pins 1-2 (Reset) JWP1 Write-Protect Enable/Disable Pins 1-2 (Enabled) Connector Description Batt
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual I-SATA 0~5 SATA 3.0 (I-SATA 0/1) and SATA 2.0 Ports (I-SATA 2~5) S-SATA 0~3 SATA 2.0 Ports (S-SATA 0~3) PCI Slot 1/Slot 2 PCI-E 3.0 x16 Slots (Available when CPU1 is populated) PCI Slot 5 PCI-E 3.0 x8 in x16 Slot (Available when CPU1 is populated) PCI Slot 3/Slot 4 PCI-E 3.0 x16 Slots (Available when CPU2 is populated) (PCH) PCI Slot 6 PCI-E 2.
Chapter 5: Advanced Serverboard Setup 5-8 Connector Definitions Power Connectors Three SMC-proprietary power connectors are located at JPW1, JPW2 and JPW9 to 12V 8-pin Power Connector Pin Definitions Pins Definition provide main power to the serverboard. 1 through 3 +12V Seven 12V, 8-pin power connectors, lo- 4 through 8 Ground cated at JPW3-8 and JPW11, are used for SATA devices and GPU cards (JPW5 5V 4-pin Power Connector Pin Definitions is for the backplane).
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Reset Connector Reset Button Pin Definitions (JF1) The reset connector is located on pins 3 and 4 of JF1 and attaches to the reset Pin# Definition switch on the computer chassis. See the 3 Reset table on the right for pin definitions. 4 Ground PWR Fail LED Pin Definitions (JF1) Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table Pin# Definition 5 3.3V on the right for pin definitions.
Chapter 5: Advanced Serverboard Setup HDD/FP UID Button The HDD/UID button connections are located on pins 13/14 of JF1. Attach a hard-drive LED cable to display HDD or HDD/UID LED Pin Definitions (JF1) SATA activity. This connection can also be used for the front panel UID (Unit Identifier) button. (The UID LED on pin 7 of JF1 works in conjunction with the UID button.) Pin# Definition 13 UID Signal/3.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual NMI Button Pin Definitions NMI Header The non-maskable interrupt header is located at JNMI1. Refer to the table on the Pin# Definition 1 Control right for pin definitions. 2 Ground Internal Buzzer The Speaker header, located at JSPK1, can be used to provide audible alarms for various beep codes. See the table on the right for pin definitions. Internal Buzzer Pin Definitions Pin# Definitions Pin 1 Pos. (+) 5V Pin 2 Neg.
Chapter 5: Advanced Serverboard Setup TPM/Port 80 Header Pin Definitions Pin# Definition TPM Header/Port 80 Pin # Definition 1 LCLK 2 GND A Trusted Platform Module/Port 80 header is located at JTPM1 to provide TPM and 3 LFRAME# 4 <(KEY)> 5 LRESET# 6 NC Port 80 support, which will enhance system 7 LAD 3 8 LAD 2 performance and data security. See the 9 +3.3V 10 LAD1 table on the right for pin definitions.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Unit Identifier Switch A Unit Identifier (UID) switch and two LED UID LED (LE4) Status indicators are provided on the serverboard. The rear UID LED (LE4) is located next to the rear UID switch. The front panel UID LED is on pins 7/8 of JF1. Connect a cable to pins 7/8 on JF1 for front panel UID indication. Pressing the UID switch will turn on both the rear and front UID LEDs. Pressing the UID switch again will turn off both LEDs.
Chapter 5: Advanced Serverboard Setup 5-9 Jumper Settings Explanation of Jumpers To modify the operation of the serverboard, jumpers can be used to choose between optional settings. 3 2 1 3 2 1 Connector Pins Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identified with a square Jumper solder pad on the printed circuit board. See the serverboard layout pages for jumper locations.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual LAN1/2 Enable/Disable LAN1/2 Enable/Disable Jumper Settings Change the setting of jumper JPL1 to enable or disable the LAN1/LAN2 Ethernet Jumper Setting ports on the serverboard. See the table on Pins 1-2 Enabled Pins 2-3 Disabled the right for jumper settings. The default setting is enabled. Definition Watch Dog Enable/Disable JWD controls the Watch Dog function.
Chapter 5: Advanced Serverboard Setup BMC Enable/Disable BMC Enable/Disable Jumper Settings Use jumper JPB1 to enable or disable the BMC (Baseboard Management Controller), which supports IPMI 2.0/KVM. See the table on the right for jumper settings. Both Jumpers Definition Pins 1-2 Enabled Pins 2-3 Disabled 5-10 Onboard Indicators LAN1/2 Port LEDs The Ethernet ports have two LEDs.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual ME Recovery JBR1 is used for ME Firmware Recovery mode, which will limit system resource ME Recovery Select Jumper Settings for essential function use only without Jumper Setting putting restrictions on power use. In the 1-2 Manufacture Mode 2-3 Normal (Default) single operation mode, online upgrade will be available via Recovery mode. See Definition the table on the right for jumper settings.
Chapter 5: Advanced Serverboard Setup 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. After accessing the ftp site, go into the CDR_Images directory and locate the ISO file for your motherboard. Download this file to create a CD/DVD of the drivers and utilities it contains. (You may also use a utility to extract the ISO file if preferred.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual SuperDoctor III The SuperDoctor® III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program allows you to monitor the environment and operations of your system. SuperDoctor III displays crucial system information such as CPU temperature, system voltages and fan status.
Chapter 5: Advanced Serverboard Setup Figure 5-8. SuperDoctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/software/SuperDoctorIII.cfm. For Linux, we recommend that you use the SuperDoctor II application instead.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual 5-13 Onboard Battery Care must be taken to assure that the chassis cover is in place when the system is operating to assure proper cooling. Out of warranty damage to the system can occur if this practice is not strictly followed. Figure 5-9. Installing the Onboard Battery Please handle used batteries carefully. Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment.
Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC118GQ chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step. Tools Required: The only tool you will need to install components and perform maintenance is a Philips screwdriver.
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual Figure 6-1. Chassis: Front and Rear Views GPU Card GPU Card Control Panel Hot-Swap Drive Bays (4) PCI Slot Power Supplies Rear I/O Ports GPU Card Note: the number of PCI slots available depends on the presence of GPUs in the server model. 6-2 Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications.
Chapter 6: Advanced Chassis Setup System Fan Failure Fan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining fans will ramp up to full speed. Replace any failed fan at your earliest convenience with the same type and model (the system can continue to run with a failed fan). Failed fans can be identified through the BIOS. (See the fan numbering in Figure 6-3. These numbers are also imprinted on the floor of the chassis.) Replacing a System Fan 1.
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual Figure 6-3. Installing a Fan Figure 6-4. Installing the Air Shroud Installing the Air Shroud Air shrouds concentrate airflow to maximize fan efficiency. The SC118GQ chassis air shroud does not require screws to set up. Note that each GPU card has its own air shroud. Installing the Air Shroud 1. Position the air shroud in the chassis as illustrated in Figure 6-4.
Chapter 6: Advanced Chassis Setup 2. Align the notch on the air shroud with the pin on the add-on card bracket. 3. Slide the pin into the back of the notch. 4. Lower the front of the air shroud over the fan tray, sliding the front notches over the pins on the fan tray. Installing Graphics (GPU) Cards The system supports three GPU cards, which are mounted in brackets to fit into the PCI-E 3.0 slots at the front of the chassis. NVIDIA Fermi M2090, Fermi M2075 and NVIDIA Kepler K10 GPUs are supported.
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual Figure 6-5. Installing GPU Cards into the Left and Right GPU Brackets Airflow 12 Left Side GPU Bracket and Cards Right Side GPU Bracket and Cards Arrows indicate direction of airflow Important Note for Kepler GPUs: note the airflow arrows on top of the GPU card.
Chapter 6: Advanced Chassis Setup 6-4 Drive Bay Installation/Removal Accessing the Drive Bays Because of their hotswap capability, you do not need to access the inside of the chassis or power down the system to install or replace hard drives. Proceed to the next section for instructions. Hard Drive Installation The hard drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airflow for the drive bays.
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual Figure 6-6. Removing a Hard Drive Carrier 12 1 Figure 6-7. Installing a Hard Drive into a Carrier Warning: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web site at http://www.supermicro.com/products/nfo/storage.
Chapter 6: Advanced Chassis Setup Figure 6-8. Removing the Power Supply Removing the Power Supply 1. First unplug the AC power cord from the failed power supply module. 2. Depress the locking tab on the power supply module. 3. Use the handle to pull it straight out with the rounded handle. Installing a New Power Supply 1. Replace the failed hot-swap unit with another identical power supply unit. 2. Push the new power supply unit into the power bay until you hear a click. 3.
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual Notes 6-10
Chapter 7: BIOS Chapter 7 BIOS 7-1 Introduction This chapter describes the AMI BIOS Setup utility for the X9DRG-HF/HTF. It also provides the instructions on how to navigate the AMI BIOS Setup utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. Starting BIOS Setup Utility To enter the AMI BIOS Setup utility screens, press the key while the system is booting up. Note: In most cases, the key is used to invoke the AMI BIOS setup screen.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual How To Change the Configuration Data The configuration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing at the appropriate time during system boot. Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Recovery User Guide posted @http://www.supermicro.com/support/manuals/.
Chapter 7: BIOS The AMI BIOS Main menu displays the following information: System Date/System Time Use this option to change the system time and date. Highlight System Time or System Date using the arrow keys. Enter new values through the keyboard and press . Press the key to move between fields. The date must be entered in Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.).
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual 7-3 Advanced Setup Configurations Select the Advanced tab to access the following submenu items. Boot Features Quiet Boot This feature allows the user to select bootup screen display between POST messages and the OEM logo. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages. The options are Enabled and Disabled.
Chapter 7: BIOS Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at bootup and allow the drives that are attached to these host adaptors to function as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adaptors will not capture Interrupt 19, and the drives attached to these adaptors will not function as bootable devices.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual • CPU Stepping • Maximum CPU Speed • Minimum CPU Speed • Processor Cores • Intel HT (Hyper-Threading) Technology • Intel VT-x Technology • Intel SMX Technology • L1 Data Cache • L1 Code Cache • L2 Cache • L3 Cache CPU Speed This item displays the speed of the CPU installed in Socket 1/Socket 2. 64-bit This item indicates if the CPU installed in Socket 1 or Socket 2 supports 64-bit technology.
Chapter 7: BIOS Active Processor Cores Set to Enabled to use a processor's second core and above. (Please refer to Intel's website for more information.) The options are All, 1, 2, 4 and 6. Limit CPUID Maximum This feature allows the user to set the maximum CPU ID value. Enable this function to boot the legacy operating systems that cannot support processors with extended CPUID functions. The options are Enabled and Disabled (for the Windows OS).
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Intel® Virtualization Technology (Available when supported by the CPU) Select Enabled to support Intel Virtualization Technology, which will allow one platform to run multiple operating systems and applications in independent partitions, creating multiple "virtual" systems in one physical computer. The options are Enabled and Disabled.
Chapter 7: BIOS CPU C6 Report (Available when Power Technology is set to Custom) Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to the operating system. During the CPU C6 State, the power to all cache is turned off. The options are Enabled and Disabled. CPU C7 Report (Available when Power Technology is set to Custom) Select Enabled to allow the BIOS to report the CPU C7 State (ACPI C3) to the operating system. CPU C7 State is a processor-specific low C-State.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Short Duration Power Limit This item displays the time period during which short duration power is maintained. The default setting is 0. Chipset Configuration North Bridge This feature allows the user to configure the settings for the Intel North Bridge.
Chapter 7: BIOS CPU1 Slot 2 PCI-E 3.0 x16 OPROM This feature allows the user to set the PCI-Exp bus speed for the slot specified above. The options are Gen1 (Generation 1), Gen2 and Gen3. CPU1 Slot 1 PCI-E 3.0 x16 OPROM This feature allows the user to set the PCI-Exp bus speed for the slot specified above. The options are Gen1 (Generation 1), Gen2 and Gen3.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual DIMM Configuration This section displays the following DIMM information. Current Memory Mode This item displays the current memory mode. Current Memory Speed This item displays the current memory speed. Mirroring This item displays if memory mirroring is supported by the motherboard. Memory mirroring creates a duplicate copy of the data stored in the memory to enhance data security.
Chapter 7: BIOS Channel Interleaving This feature selects from the different channel interleaving methods. The options are Auto, 1 Way, 2 Way, 3, Way, and 4 Way. Rank Interleaving This feature allows the user to select a rank memory interleaving method. The options are Auto, 1 Way, 2 Way, 4, Way, and 8 Way. Patrol Scrub Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor (the original source).
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual South Bridge Configuration This feature allows the user to configure the settings for the Intel PCH chip. PCH Information This feature displays the following PCH information. Name: This item displays the name of the PCH chip. Stepping: This item displays the status of the PCH stepping. USB Devices: This item displays the USB devices detected by the BIOS. All USB Devices This feature enables all USB ports/devices. The options are Disabled and Enabled.
Chapter 7: BIOS SATA Mode Use this feature to configure SATA mode for a selected SATA port. The options are Disabled, IDE Mode, AHCI Mode and RAID Mode. The following are displayed depending on your selection: IDE Mode The following items are displayed when IDE Mode is selected: Serial-ATA (SATA) Controller 0~1 Use this feature to activate or deactivate the SATA controller, and set the compatibility mode. The options for SATA Controller 0 are Disabled, Enhanced, and Compatible.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual SCU (Storage Control Unit) Configuration Storage Controller Unit Select Enabled to enable PCH SCU storage devices. The options are Disabled and Enabled. OnChip SCU Option ROM Select Enabled to support the onboard SCU Option ROM to boot up the system via a storage device. The options are Disabled and Enabled. SCU Port 0~SCU Port 3: The AMI BIOS will automatically detect the onboard SCU devices and display the status of each SCU device as detected.
Chapter 7: BIOS Maximum Read Request Select Auto to allow the system BIOS to automatically set the maximum Read Request size for a PCI-E device to enhance system performance. The options are Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes. ASPM Support This feature allows the user to set the Active State Power Management (ASPM) level for a PCI-E device. Select Force L0 to force all PCI-E links to operate at L0 state.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Super IO Configuration Super IO Chip: This item displays the Super IO chip used in the motherboard. Serial Port 1 Configuration Serial Port Select Enabled to enable a serial port specified by the user. The options are Enabled and Disabled. Device Settings This item displays the settings of Serial Port 1. Change Settings Use this feature to set the optimal Platform Environment Control Interface (PECI) setting for a serial port specified.
Chapter 7: BIOS Device Mode Use this feature to select the desired mode for a serial port specified. The options are Normal and High Speed. Serial Port Console Redirection COM 1/SOL These two submenus allow the user to configure the following Console Redirection settings for a COM Port specified by the user. Console Redirection Select Enabled to use a COM Port selected by the user for Console Redirection. The options are Enabled and Disabled.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits. The options are None, Even, Odd, Mark and Space. Stop Bits A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication.
Chapter 7: BIOS Console Redirection Select Enabled to use a COM Port selected by the user for Console Redirection. The options are Enabled and Disabled. Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user. Out-of-Band Management Port The feature selects a serial port used by the Microsoft Windows Emergency Management Services (EMS) to communicate with a remote server.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual ACPI Sleep State Use this feature to select the ACPI State when the system is in sleep mode. Select S1 (CPU_Stop_Clock) to erase all CPU caches and stop executing instructions. Power to the CPU(s) and RAM is maintained, but RAM is refreshed. Select Suspend Disabled to use power-reduced mode. Power will only be supplied to limited components (such as RAMs) to maintain the most critical functions of the system.
Chapter 7: BIOS TPM Active Status This item displays the status of TPM Support to indicate if TPM is currently active or deactivated. TPM Owner Status This item displays the status of TPM Ownership. Intel TXT (LT-SX) Configuration Intel TXT (LT-SX) Hardware Support This feature indicates if the following hardware components support the Intel Trusted Execution Technology.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual iSCSI Configuration: This item displays iSCSI configuration information: iSCSI Initiator Name This item displays the name of the iSCSI Initiator, which is a unique name used in the world. The name must use IQN format.
Chapter 7: BIOS 7-4 • Chip Type • PCI Device ID • PCI Bus:Device:Function • Link Status • Factory MAC Address • Alternate MAC Address Event Logs Select the Event Logs tab to access the following submenu items. Change SMBIOS Event Log Settings This feature allows the user to configure SMBIOS Event settings. Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during system boot. The options are Enabled and Disabled.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Runtime Error Logging Support Select Enabled to support Runtime Error Logging. The options are Enabled and Disabled. Memory Correctable Error Threshold This feature allows the user to enter the threshold value for correctable memory errors. The default setting is 10. PCI Error Logging Support Select Enabled to support error event logging for PCI slots. The options are Enabled and Disabled.
Chapter 7: BIOS View System Event Log This item allows the user to view the event in the system event log. Select this item and press to view the status of an event in the log. Date/Time/Error Code/Severity 7-5 IPMI Select the IPMI (Intelligent Platform Management Interface) tab to access the following submenu items. IPMI Firmware Revision This item indicates the IPMI firmware revision used in your system. IPMI Status This item indicates the status of the IPMI firmware installed in your system.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Erasing Settings Erase SEL Select Yes, On next reset to erase all system event logs upon next system reboot. Select Yes, On every reset to erase all system event logs upon each system reboot. Select No to keep all system event logs after each system reboot. The options are No, Yes, On next reset, and Yes, On every reset. When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full.
Chapter 7: BIOS Subnet Mask This item displays the sub-network that this computer belongs to. The value of each three-digit number separated by dots should not exceed 255. Station MAC Address This item displays the Station MAC address for this computer. Mac addresses are 6 two-digit hexadecimal numbers. Gateway IP Address This item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i.e., 192.168.10.253).
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Delete Boot Option This feature allows the user to select a EFI boot device to delete from the boot priority list. Delete Boot Option Select the desired boot device to delete. 7-7 Security This menu allows the user to configure the following security settings for the system. Administrator Password Use this feature to set the Administrator Password which is required to enter the BIOS setup utility.
Chapter 7: BIOS 7-8 Save & Exit This submenu allows the user to configure the Save and Exit settings for the system. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration, and reboot the computer. Select Discard Changes and Exit, and press .
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Discard Changes Select this feature and press to discard all the changes and return to the BIOS setup. When the dialog box appears, asking you if you want to load previous values, click Yes to load the values previous saved, or click No to keep the changes you've made so far. Restore Optimized Defaults Select this feature and press to load the optimized default settings that help optimize system performance.
Appendix A: BIOS POST Error Codes Appendix A BIOS POST Error Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen. Fatal errors will not allow the system to continue the boot-up procedure. If a fatal error occurs, you should consult with your system manufacturer for possible repairs.
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual Notes A-2
Appendix B: System Specifications Appendix B System Specifications Processors Two Intel Xeon E5-2600 series processors Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel C602 BIOS 32 Mb AMIBIOS® SPI Flash ROM Memory Capacity Eight DIMM sockets supporting up to 512 GB registered ECC LDIMMs or 256 GB of DDR3-1866/1600/1333/1066/800 RDIMMs Note: See the memory section in Chapter 5 for details.
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual Chassis SC118GQ-R1800B (1U rackmount) Dimensions: (WxHxD) 17.2 x 1.7 x 30.6 in. (437 x 43 x 777 mm) System Cooling Ten sets of 4-cm counter-rotating cooling fans (fan speed controlled by BIOS setting) System Input Requirements AC Input Voltage: 100-240 VAC Rated Input Current: 1000W: 100-120V/12-10A, 1200W: 120-140V/12-10A, 1800W: 200-240V/10-8.
Appendix B: System Specifications (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual Notes B-4