User`s manual

4-16
X8DTU/X8DTU-F User’s Manual
Serial Port 2 Attribute
This feature allows the user to set COM 2 as a normal serial port or a virtual COM
port used for SOL (Serial Over LAN). The options are SOL, and COM.
Remote Access Con guration
Remote Access
This allows the user to enable the Remote Access feature. The options are Disabled
and Enabled. If Remote Access is set to Enabled, the following items will display:
Serial Port Number
This feature allows the user to decide which serial port to use for Console Redirec-
tion. The options are COM 1 and COM 2.
Serial Port Mode
This feature allows the user to set the serial port mode for Console Redirection.
The options are 115200 8, n 1; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1; and
9600 8, n, 1.
Flow Control
This feature allows the user to set the ow control for Console Redirection. The
options are None, Hardware, and Software.
Redirection After BIOS POST
Select Disabled to turn off Console Redirection after Power-On Self-Test (POST).
Select Always to keep Console Redirection active all the time after POST. (Note:
This setting may not be supported by some operating systems.) Select Boot Loader
to keep Console Redirection active during POST and when the Boot Loader is
booting. The options are Disabled, Boot Loader, and Always.
Terminal Type
This feature allows the user to select the target terminal type for Console Redirec-
tion. The options are ANSI, VT100, and VT-UTF8.
VT-UTF8 Combo Key Support
Select Enabled to enable a terminal keyboard to send commands from a remote
console. The options are Enabled and Disabled.
Sredir Memory Display Delay
This feature de nes the length of time in seconds to display memory information.
The options are No Delay, Delay 1 Sec, Delay 2 Sec, and Delay 4 Sec.