User`s manual

C-4
C7SIM-Q User's Manual
Intel®MEPlatformConguration
Intel ME State Control
Disabling the Intel ME through the MEBX prevents the Intel ME code from executing.
This allows an IT technician to eliminate the Intel ME as the potential problem. This
is used primarily for debugging purposes. The options are Enable and Disable.
Change ME Password
At the prompt, enter your new password. Please be aware of the password guideline
as described on page C-2.
Password Policy
Intel ME has two passwords: The Intel MEBx password, which is entered when
physically in front of the system, and the network password, which is entered
across a network. Both are the same by default until the network password is
changed. Once the network password is changed, these passwords will always
be separate.
Options:
Default Password - If the default password has not been changed yet, the
Intel MEBx password can be changed via the network interface.
During Setup and Conguration - The Intel MEBx password can only be
changed during setup. Once the setup and conguration is nished, it can
no longer be changed through the network interface.
Anytime - The Intel MEBx password can be changed via the network
interface anytime.
Note: The menu items list has been extended to the bottom for illustration pur-
poses.