User`s manual

2-8
H8SSL-i2 User's Manual
Overheat/Fan Fail LED
Connect an LED to the OH connection
on pins 7 and 8 of JF1 to provide ad-
vanced warning of chassis overheat-
ing. Refer to the table on the right for
pin de nitions.
NIC1 LED
The NIC1 (Network Interface Control-
ler) LED connection is located on pins
11 and 12 of JF1. Attach the NIC1
LED cable to display network activity.
Refer to the table on the right for pin
de nitions.
Power Fail LED
The Power Fail LED connection is lo-
cated on pins 5 and 6 of JF1. See the
table on the right for pin de nitions.
NIC2 LED
The NIC2 (Network Interface Control-
ler) LED connection is located on pins
9 and 10 of JF1. Attach the NIC2
LED cable to display network activity.
Refer to the table on the right for pin
de nitions.
OH/Fan Fail LED
Pin De nitions (JF1)
Pin# De nition
7 Vcc
8 Control
Power Fail LED
Pin De nitions (JF1)
Pin# De nition
5 Vcc
6 Control
NIC1 LED
Pin De nitions (JF1)
Pin# De nition
11 Vcc
12 NIC1 Active
NIC2 LED
Pin De nitions (JF1)
Pin# De nition
9 Vcc
10 NIC2 Active
HDD LED
The HDD (IDE Hard Disk Drive) LED
connection is located on pins 13 and
14 of JF1. Attach the IDE hard drive
LED cable to display disk activity.
Refer to the table on the right for pin
de nitions.
HDD LED
Pin De nitions (JF1)
Pin# De nition
13 Vcc
14 HD Active
Note: This feature is only available when using
redundant power supplies.