SUPER H8DGU H8DGU-F USER’S MANUAL Revision 1.
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com. Super Micro Computer, Inc.
Preface Preface About This Manual This manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information for the installation and use of the H8DGU(-F) serverboards. The H8DGU(-F) serverboard is based on the AMD® SR5670/SP5100 chipset and supports four AMD Socket G34 type processors with up to 128 GB of ECC/NonECC Unbuffered or 512 GB of ECC Registered DIMM DDR3-1600/1333/1066 Mhz SDRAM.
Table of Contents Table of Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 Checklist .......................................................................................................... 1-1 1-2 Contacting Supermicro .................................................................................... 1-2 1-3 Serverboard Features ...............................................................
H8DGU(-F) SERVERBOARD USER'S MANUAL NMI Button ............................................................................................... 2-14 Universal Serial Bus Ports ....................................................................... 2-14 USB Headers ........................................................................................... 2-14 Fan Headers............................................................................................. 2-15 Serial Ports ...........................
Table of Contents Using the DotHill and Adaptec RAID Utility .................................................. 2-28 Installing the RAID Driver During OS Installation ......................................... 2-28 Supero Doctor III ........................................................................................... 2-29 2-14 Serverboard Battery ...................................................................................... 2-31 Chapter 3 Troubleshooting 3-1 Troubleshooting Procedures .....
Chapter 1: Introduction Chapter 1 Introduction 1-1 Overview Checklist Congratulations on purchasing your computer motherboard from an acknowledged leader in the industry. Supermicro boards are designed with the utmost attention to detail to provide you with the highest standards in quality and performance. Please check that the following items have all been included with your motherboard. If anything listed here is damaged or missing, contact your retailer.
H8DGU(-F) Serverboard User’s Manual 1-2 Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) Web Site: www.supermicro.com support@supermicro.com (Technical Support) Europe Address: Super Micro Computer B.V.
Chapter 1: Introduction Figure 1-1.
H8DGU(-F) Serverboard User’s Manual Figure 1-2. H8DGU-F Serverboard Layout (not drawn to scale) UID FAN8 JPL1 KB/MOUSE LAN1 LAN2 UIOP USB0/1 IPMI_LAN COM1 VGA LE1 P2-DIMM1B P2-DIMM1A P2-DIMM2B P2-DIMM2A P2-DIMM3B P2-DIMM3A P2-DIMM4B P2-DIMM4A CPU2 PCI-E 2.0 x16 SLOT JI2C1 JI2C2 COM2 DP1 JPG1 JWD BATTERY JTPM1 P1-DIMM4B P1-DIMM3B P1-DIMM4A P1-DIMM2B P1-DIMM3A P1-DIMM1B P1-DIMM2A T-SGPIO2 T-SGPIO1 DP2 P1-DIMM1A PCI-E 2.
Chapter 1: Introduction H8DGU(-F) Quick Reference Jumper Description Default Setting JBT1 CMOS Clear (See Section 2-7) JI2C1/JI2C2 I2C to PCI-E Slot Enable/Disable Both Open (Disabled) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPL1 LAN 1/2 Enable/Disable Pins 1-2 (Enabled) JWD Watch Dog Pins 1-2 (Reset) LED Description LAN Ports LEDs for the LAN Ethernet ports Dedicated IPMI LAN LEDs for the dedicated IPMI LAN Ethernet port LE1 LED for UID Button DP1 LED for BMC Heartbeat DP2
H8DGU(-F) Serverboard User’s Manual 1-3 Serverboard Features CPU • Dual AMD Opteron 6000 series (AMD Socket G34 type) processors Memory • Sixteen (sixteen (16)) single/dual/tri/quad channel DIMM slots supporting up to 128 GB of ECC/Non-ECC Unbuffered, 512 GB of ECC Low-profile Registered LRDIMM, or 512 GB of ECC Registered DIMM DDR3-1600/1333/1066 Mhz speed, SDRAM memory Note: Refer to Section 2-5 before installing memory and our web site for recommended DIMMs.
Chapter 1: Introduction • Auto-switching voltage regulator for the CPU core • CPU thermal trip support • I2C temperature sensing logic ACPI Features • Microsoft OnNow • Slow blinking LED for suspend state indicator • BIOS support for USB keyboard • Hardware BIOS Virus protection • Internal/external modem ring-on Onboard I/O • UIO (Universal Input/Output) ready • Six (6) SATA ports supported by an on-chip SATA controller (RAID 0, 1 and 10 supported) • Two (2) Fast UART 16550 compatibl
H8DGU(-F) Serverboard User’s Manual Figure 1-3. AMD SR5670/SP5100 Chipset: System Block Diagram DIMM A1 DIMM A0 DIMM B1 DIMM B0 DIMM C1 DIMM C0 DIMM D1 DIMM D0 HT3 Link 16x16-6.4GT/s AMD Socket G34 CPU2 HT3 Link 16x16-6.4GT/s AMD Socket G34 CPU1 HT3 Link (8+8)x(8+8)-6.4GT/s DIMM A1 DIMM A0 DIMM B1 DIMM B0 DIMM C1 DIMM C0 DIMM D1 DIMM D0 HT3 Link 16x16-5.
Chapter 1: Introduction 1-4 Chipset Overview The H8DGU(-F) serverboard is based on the AMD SR5670/SP5100 chipset. This chipset functions as a Media and Communications Processor (MCP). Controllers for the system memory are integrated directly into AMD Opteron processors. AMD SR5670/SP5100 Chipset The AMD SR5670/SP5100 are each a single-chip, high-performance HyperTransport peripheral controller.
H8DGU(-F) Serverboard User’s Manual CPU Overheat/Fan Fail LED and Control This feature is available when the user enables the CPU overheat/Fan Fail warning function in the BIOS. This allows the user to define an overheat temperature. When this temperature is exceeded or when a fan failure occurs, the Overheat/Fan Fail warning LED is triggered. Auto-Switching Voltage Regulator for the CPU Core The 6-phase-switching voltage regulator for the CPU core can support up to AMD Opteron 6000SE series processors.
Chapter 1: Introduction 1-7 Power Supply As with all computer products, a stable power source is necessary for proper and reliable operation. It is even more important for processors that have high CPU clock rates. The H8DGU(-F) serverboard requires the use of proprietary power supplies. Please refer to the pinout information for the power connectors in Section 6 of Chapter 2 for detailed information on power requirements.
H8DGU(-F) Serverboard User’s Manual 1-9 UIO The H8DGU(-F) is a specially-designed serverboard that features Supermicro's UIO (Universal I/O) technology. UIO serverboards have a PCI-Express x4 and x8 signals that can support PCI-E cards or any one of several types of UIO card types to add SAS ports, additional LAN ports, Infiniband®, etc. to the serverboard. This allows the user to tailor the serverboard to their own needs.
Chapter 2: Installation Chapter 2 Installation 2-1 Standardized Warning Statements About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components.
H8DGU(-F) SERVERBOARD USER'S MANUAL Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
Chapter 2: Installation Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations. 製品の廃棄 この製品を廃棄処分する場合、国の関係する全ての法律・条例に従い処理する必要が あります。 警告 本产品的废弃处理应根据所有国家的法律和规章进行。 警告 本產品的廢棄處理應根據所有國家的法律和規章進行。 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
H8DGU(-F) SERVERBOARD USER'S MANUAL 2-2 Static-Sensitive Devices Electrostatic Discharge (ESD) can damage electronic components. To prevent damage to your system board, it is important to handle it very carefully. The following measures are generally sufficient to protect your equipment from ESD. Precautions • • • • • • • Use a grounded wrist strap designed to prevent static discharge. Touch a grounded metal object before removing the board from the antistatic bag.
Chapter 2: Installation 2-3 Processor and Heatsink Installation Warning: Exercise extreme caution when handling and installing the processor. Always connect the power cord last and always remove it before adding, removing or changing any hardware components. Installation Procedure Follow the procedures as listed below to install the motherboard into a chassis. 1. Install the processor(s) and the heatsink(s). 2. Install the motherboard in the chassis. 3. Install the memory and add-on cards. 4.
H8DGU(-F) SERVERBOARD USER'S MANUAL 3. Use your thumb and your index finger to hold the CPU. Locate and align pin 1 of the CPU socket with pin 1 of the CPU. Both are marked with a triangle. 4. Align pin 1 of the CPU with pin 1 of the socket. Once aligned, carefully place the CPU into the socket. Do not drop the CPU on the socket, move the CPU horizontally or vertically or rub the CPU against the socket or against any pins of the socket, which may damage the CPU and/or the socket. Triangle 5.
Chapter 2: Installation Installing the Heatsinks We recommend the use of active type heatsinks (except for 1U systems). Use any onboard fan header for the CPU's heatsink fan. To install the heatsink, please follow the installation instructions that are included with your heatsink package. Note: Make sure the heatsink is placed so that the fins of the heatsink are in the direction of the airflow in your system.
H8DGU(-F) SERVERBOARD USER'S MANUAL 2. Install to slots CPU1/DIMM1A, CPU1/DIMM2A, CPU1/DIMM3A and CPU1/ DIMM4A, etc. Always install in groups of four and in the numerical order of the DIMM slots. See support information below. 3. Gently press down on the memory module until it snaps into place. 4. With four DIMMs installed, repeat step 2 to populate the CPU2 DIMM slots. Always install four DIMMs to both CPU DIMM slots for more efficient operation.
Chapter 2: Installation Memory Population for Optimal Performance -For a Serverboard with One CPU (CPU1) Installed # DIMMS CPU Channel 1 4 DIMMs CPU1 P1-1A 8 DIMMs CPU1 P1-1A Channel 2 P1-2A P1-1B P1-2A Channel 3 P1-3A P1-2B P1-3A Channel 4 P1-4A P1-3B P1-4A P1-4B Memory Population for Optimal Performance -For a Serverboard with Two CPUs (CPU1 & CPU2) Installed # DIMMS CPU Channel 1 Channel 2 Channel 3 Channel 4 CPU1 P1-1A P1-2A P1-3A P1-4A CPU2 P2-1A P2-2A P2-3A P2-4A CP
H8DGU(-F) SERVERBOARD USER'S MANUAL 2-6 PCI Expansion Cards A riser card is used to support one standard size (full height full length) PCI expansion card. Installing a PCI Expansion Card 1. Confirm that you have the correct riser card for your chassis model and the add-on card includes a standard bracket. 2. Remove the chassis cover. 3. Install the riser card by sliding card into the appropriate slot in the motherboard. 4. Choose the PCI slot shield in which to place the add-on card. 5.
Chapter 2: Installation 2-7 I/O Port and Control Panel Connections The I/O ports are color coded in conformance with the PC99 specification to make setting up your system easier. See Figure 2-2 below for the colors and locations of the various I/O ports. Figure 2-2. I/O Port Locations and Definitions 2 1 4 3 5 6 7 8 Rear I/O Ports 1. Keyboard 5. COM1 2. PS/2 Mouse 6. VGA Port 3. USB0/1 7. LAN1 4. IPMI LAN (H8DGU-F only 8.
H8DGU(-F) SERVERBOARD USER'S MANUAL 2-8 Connector Definitions ATX Power 20-pin Connector Pin Definitions (JPW1) Power Connectors A 20-pin main power supply connector(JPW1) and two 8-pin CPU PWR connectors (JPW2/JPW3) on the motherboard. These power connectors meet the SSI EPS 12V specification. In addition to the 20-pin ATX power connector, the 12V 8-pin CPU PWR connectors at JPW2/JPW3 must also be connected to your power supply. See the table on the right for pin definitions.
Chapter 2: Installation Reset Connector Reset Button Pin Definitions (JF1) The reset connector is located on pins 3 and 4 of JF1 and attaches to the reset switch on the computer chassis. See the table on the right for pin definitions. Pin# Definition 3 Reset 4 Ground Power Fail LED PWR Fail LED Pin Definitions (JF1) The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin definitions.
H8DGU(-F) SERVERBOARD USER'S MANUAL HDD LED HDD LED Pin Definitions (JF1) The HDD LED connections are located on pins 13 and 14 of JF1. Attach a hard-drive LED cable to display HDD or SATA activities. Refer to the table on the right for pin definitions. Pin# Definition 13 Vcc 14 HDD LED Power LED Connector Power LED Pin Definitions (JF1) The Power LED connector is on pins 15 and 16 of JF1. See the table on the right for pin definitions. Pin# Definition 15 3.
Chapter 2: Installation Fan Headers Fan Header Pin Definitions This motherboard has eight fan headers (Fan1 to Fan8). These 4-pin fans headers are backward compatible with 3-pin fans. However, fan speed control is available for 4-pin fans only. The fan speeds are controlled by the BIOS or IPMI (HDGU-F). See the table on the right for pin definitions Serial Ports The COM1 serial port is located beside the VGA port. Refer to the motherboard layout for the location of the COM2 header.
H8DGU(-F) SERVERBOARD USER'S MANUAL Trusted Platform Module Header The JTPM1 header is used to connect a Trusted Platform Module (TPM), available separately from a third-party vendor. A TPM is a security device that allows encryption and authentication of hard drives, disallowing access if the TPM associated with it is not installed in the system. See the table on the right for pin definitions.
Chapter 2: Installation Power LED/Speaker PWR LED Connector Pin Definitions On the JD1 header, pins 1~3 are used for power LED indication, and pins 4-7 are for the speaker. See the tables on the right for pin definitions. If you wish to use the onboard speaker, you should close pins 6~7 with a jumper. Connect a cable to pins 4~7 of JD1 to use an external speaker.
H8DGU(-F) SERVERBOARD USER'S MANUAL LAN1/2 (Ethernet Ports) Two Gigabit Ethernet ports (designated LAN1 and LAN2) are located beside the VGA port. Additionally, there is a dedicated LAN for IPMI on top of the two rear USB ports. These Ethernet ports accept RJ45 type cables.
Chapter 2: Installation UIO Power Connector A Universal I/O (UIO) Power connector is located next to the UID switch. Connect this connector to the power supply to provide adequate power to the UIO device installed on the slot for this device to function properly.
H8DGU(-F) SERVERBOARD USER'S MANUAL 2-9 Jumper Settings 3 2 1 3 2 1 Connector Pins Explanation of Jumpers To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit board. See the diagram at right for an example of jumping pins 1 and 2. Refer to the motherboard layout page for jumper locations.
Chapter 2: Installation I2C to PCI-Express Slot I2C to PCI-Express Slot Jumper Settings (JI2C1/JI2C2) JI2C1/JI2C2 allows you to enable the I2C bus to communicate with the PCIExpress slot. For the jumpers to work properly, please set both jumpers to the same setting. If enabled, both jumpers must be enabled. If disabled, both jumpers must be disabled. See the table on the right for jumper settings.
H8DGU(-F) SERVERBOARD USER'S MANUAL 2-10 Onboard Indicators GLAN LED GLAN LEDs There are two LAN ports (LAN1/2) on the motherboard. Each Ethernet LAN port has two LEDs. The Yellow LED on the right indicates connection and activity. The Link LED on the left side may be green, amber or off to indicate the speed of the connection. See the tables at right for more information.
Chapter 2: Installation Power LED Power LED (DP2) DP2 is an Onboard Power LED. When this LED is lit, it means power is present on the serverboard. Be sure to turn off the system and unplug the power cord(s) before removing or installing components.
H8DGU(-F) SERVERBOARD USER'S MANUAL 2-12 Enabling SATA RAID Now that the hardware is set up, you must install the operating system and the SATA RAID drivers, if you wish to use RAID with your SATA drives. The installation procedure differs depending on whether you wish to have the operating system installed on a RAID array or on a separate non-RAID drive. See the instructions below for details.
Chapter 2: Installation Enabling SATA RAID in the BIOS Before installing the Windows operating system, you must change some settings in the BIOS. Boot up the system and hit the key to enter the BIOS Setup Utlility. After the setup utility loads, 1. Use the arrow keys to move to the "Exit" menu. Scroll down using the arrow keys to "Load Optimal Defaults" and press . Select "OK" to confirm, then to load the default settings. 2.
H8DGU(-F) SERVERBOARD USER'S MANUAL Figure 2-5. DotHill RAID Utility Program Screen Figure 2-6.
Chapter 2: Installation 2-13 Installing Drivers The Supermicro Website contains drivers and utilities for your system at ftp://ftp. supermicro.com, some of which must be installed, such as the chipset driver. After downloading and installing the drivers and utilities, the display shown in Figure 2-7 should appear. Click the icons showing a hand writing on paper to view the readme files for each item.
H8DGU(-F) SERVERBOARD USER'S MANUAL Using the DotHill and Adaptec RAID Utility The RAID Utility program allows you to define the drives you want to include in the RAID array and the mode and type of RAID. Installing the RAID Driver During OS Installation You may also use the procedure below to install the RAID driver during the Windows OS installation: 1. With the Windows OS installation CD-ROM in the CD drive, restart the system. 2. Press again to continue with the Windows setup. 3.
Chapter 2: Installation Supero Doctor III The SuperDoctor® III program is a Web base management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program included on the CD-ROM that came with your motherboard allows you to monitor the environment and operations of your system. SuperDoctor III displays crucial system information such as CPU temperature, system voltages and fan status.
H8DGU(-F) SERVERBOARD USER'S MANUAL Figure 2-9. Supero Doctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/software/ SuperDoctorIII.cfm.For Linux, we recommend that you use the SuperoDoctor II application instead.
Chapter 2: Installation 2-14 Serverboard Battery Caution: There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 2-10). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032). Dispose of used batteries according to the manufacturer's instructions. Figure 2-10. Installing the Onboard Battery OR Please handle used batteries carefully.
H8DGU(-F) SERVERBOARD USER'S MANUAL Notes 2-32
Chapter 3: Troubleshooting Chapter 3 Troubleshooting 3-1 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘Technical Support Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter. Always disconnect the AC power cord before adding, changing or installing any hardware components. Before Power On 1.
H8DGU(-F) SERVERBOARD USER'S MANUAL No Video 1. If the power is on but you have no video, remove all the add-on cards and cables. 2. Use the speaker to determine if any beep codes exist. Refer to Appendix A for details on beep codes. Note: If you are a system integrator, VAR or OEM, a POST diagnostics card is recommended. For I/O port 80h codes, refer to Appendix B. Memory Errors 1. Make sure that the DIMM modules are properly and fully installed. 2.
Chapter 3: Troubleshooting Note: Not all BIOS can be flashed depending on the modifications to the boot block code. 3. If you still cannot resolve the problem, include the following information when contacting us for technical support: • • • Serverboard model and PCB revision number BIOS release date/version (this can be seen on the initial display when your system first boots up) System configuration An example of a Technical Support form is posted on our web site.
H8DGU(-F) SERVERBOARD USER'S MANUAL Question: Why can't I turn off the power using the momentary power on/off switch? Answer: The instant power off function is controlled in BIOS by the Power Button Mode setting. When the On/Off feature is enabled, the motherboard will have instant off capabilities as long as the BIOS has control of the system.
Chapter 4: BIOS Chapter 4 BIOS 4-1 Introduction This chapter describes the AMIBIOS™ Setup utility for the H8DGU(-F) serverboard. The 16 Mb AMI BIOS® is stored in a flash chip and can be easily upgraded using a floppy disk-based program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the Manual Download area of our web site for any changes to BIOS that may not be reflected in this manual.
H8DGU(-F) Serverboard User’s Manual 4-2 Main Menu When you first enter AMI BIOS Setup Utility, you will see the Main Menu screen. You can always return to the Main Menu by selecting the Main tab on the top of the screen with the arrow keys. The Main Menu screen provides you with a system overview, which includes the version, built date and ID of the AMIBIOS, the type, speed and number of the processors in the system and the amount of memory installed in the system.
Chapter 4: BIOS Wait for F1 if Error This setting controls the system response when an error is detected during the boot sequence. When enabled, BIOS will stop the boot sequence when an error is detected, at which point you will need to press the F1 button to re-enter the BIOS setup menu. The options are Enabled and Disabled. Hit 'DEL' Message Display Use this option to Enable or Disable the "Press DEL to run setup" message in POST. Interrupt 19 Capture Select Enabled to allow ROMs to trap Interrupt 19.
H8DGU(-F) Serverboard User’s Manual Processor and Clock Options CPU Configuration This displays static information on the Module Version, Physical Count and Logical Count for the system's processor(s) and clock. CPU Information The information for the installed processor includes Revision, Cache L1/L2/L3, Speed, NB CLK, Able to Change Frequency and uCode Patch Level. GART Error Reporting This option should remain disabled for normal operation.
Chapter 4: BIOS CPU Down Core Mode This option sets down core support for the CPU. Options include Disabled, 1 Core through n Cores in odd numbered increments. The value n is depend on the core per CPU node. C1E Support This option enables C1E support. Options include Enabled and Disabled. Clock Speed Spectrum This option enables or disables spread spectrum modulation.
H8DGU(-F) Serverboard User’s Manual Bank Swizzle Mode This setting Enables or Disables the bank swizzle mode. ECC Configuration ECC Mode This submenu affects the DRAM scrub rate based on its setting. Options include Disabled, Basic, Good, Super, Max and User. Selecting User activates the other options for user setting. DRAM ECC Enable This setting allows hardware to report and correct memory errors automatically, maintaining system integrity. Options are Enabled or Disabled.
Chapter 4: BIOS SouthBridge Chipset Configuration OHCI/EHCI HC Device Functions These settings allow you to either Enable or Disable functions for OHCI or EHCI bus devices. USB 2.0 Controller Mode Use this setting to configure the USB 2.0 Controller in either Hi-Speed (480 Mps) or Full Speed (12 Mps) mode. Options include Enabled (Hi-Speed Mode) or Disabled (Full Speed Mode). Legacy USB Support Select "Enabled" to enable the support for USB Legacy.
H8DGU(-F) Serverboard User’s Manual Primary/Secondary/Third/Fourth IDE Master/Slave LBA/Large Mode LBA (Logical Block Addressing) is a method of addressing data on a disk drive. The options are Disabled and Auto. Block (Multi-Sector Transfer) Block mode boosts IDE drive performance by increasing the amount of data transferred. Only 512 bytes of data can be transferred per interrupt if block mode is not used. Block mode allows transfers of up to 64 KB per interrupt.
Chapter 4: BIOS S.M.A.R.T. Self-Monitoring Analysis and Reporting Technology (SMART) can help predict impending drive failures. Select "Auto" to allow BIOS to auto detect hard disk drive support. Select "Disabled" to prevent AMI BIOS from using the S.M.A.R.T. Select "Enabled" to allow AMI BIOS to use the S.M.A.R.T. to support hard drive disk. The options are Disabled, Enabled, and Auto. 32-Bit Data Transfer Select "Enabled" to activate the function of 32-Bit data transfer.
H8DGU(-F) Serverboard User’s Manual PCIe Slot from SXB1 This setting Enables or Disables the slot OPROM for the SXB1 slot. PCIe Slot rom SXB2 This setting Enables or Disables the slot OPROM for the SXB2 slot. Onboard LAN Option ROM Select This setting allows you to select the onboard LAN option ROM for iSCSI or PXE. Load Onboard LAN 1 Option ROM This option allows you to Enable or Disable the onboard LAN 1 option ROM.
Chapter 4: BIOS Remote Access Configuration Remote Access Use this option to Enable or Disable Remote Access in your system. If enabled, the settings below will appear. Serial Port Number Use this setting to select the serial port for console redirection. Options include COM1, COM2*. The displayed base address and IRQ for the serial port changes to reflect the selection you make. Note: Make sure the selected port is enabled. Serial Port Mode Selects the serial port settings to use.
H8DGU(-F) Serverboard User’s Manual Hardware Health Configuration CPU Overheat Alarm This setting allows you to specify the type of alarm for CPU overheating. Options include The Early Alarm and The Default Alarm. Fan Speed Control This feature allows the user to determine how the system will control the speed of the onboard fans.
Chapter 4: BIOS The Default Alarm (default setting) is enabled when the Tctl value = 70, and is disabled when the Tctl value drops from 70 to 67. When COA (either Early or Default Alarm) is enabled, the following actions are required to be executed: • • • • System overheating LED is required to be ON and to solid red. Onboard buzzer or speaker is required to be ON and to be a continuous sound. All system fans are required to be operated at full speed.
H8DGU(-F) Serverboard User’s Manual ACPI Configuration PS2 KB/MS Wakeup This setting allows you to Enable or Disable PS2 keyboard and mouse wakeup. ACPI Aware O/S This setting Enables or Disables ACPI support for the system's operating system. Options include Yes (enabled) or No (disabled). ACPI APIC Support Determines whether to include the ACPI APIC table pointer in the RSDT pointer list. The available options are Enabled and Disabled.
Chapter 4: BIOS Set LAN Configuration Use the "+" and "-" keys to choose the desired channel number. This displays Channel Number and Channel Number Status information. This menu contains options for inputing settings for the SET LAN Configuration Command. See IPMI 1.5 Specification, table 11.1 for details. Use the "+" and "-" keys to choose the desired channel number. Note: Each question in this group may take a considerable amount of time.
H8DGU(-F) Serverboard User’s Manual Event Log Configuration View Event Log Pressing the Enter key will open the event log. Use the "" and "" keys to navigate through the system event log. Mark All Events as Read Selecting this and pressing the Enter key marks all events as read in the event log. Clear Event Log Selecting this and pressing the Enter key clears the system event log. SR56x0 (RD890S) PCIE Error Log This setting allows you set an error log ofr PCIE errors. Options include Yes or No.
Chapter 4: BIOS 4-4 Boot Menu Boot Device Priority This feature allows you to prioritize the boot sequence from the list of available devices. A device that is in parenthesis has been disabled in the corresponding type menu. Removable Drives This feature allows you to specify the boot sequence from the list of available removable drives. A device that is in parenthesis has been disabled in the corresponding type menu.
H8DGU(-F) Serverboard User’s Manual Retry Boot Devices This option allows you to retry boot devices. Options include Enabled and Disabled. 4-5 Exit Menu Select the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Save Changes and Exit When you have completed the system configuration changes, select this option to leave BIOS Setup and reboot the computer, so the new system configuration parameters can take effect.
Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen. Fatal errors are those which will not allow the system to continue the boot-up procedure.
H8DGU(-F) Serverboard User’s Manual Notes A-2
Appendix B: BIOS POST Checkpoint Codes Appendix B BIOS POST Checkpoint Codes When AMIBIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, diagnostic equipment can be attached to the computer to read I/O port 0080h. B-1 Uncompressed Initialization Codes The uncompressed initialization checkpoint codes are listed in order of execution: Checkpoint Code Description D0h The NMI is disabled. Power on delay is starting.
H8DGU(-F) SERVERBOARD USER'S MANUAL B-2 Bootblock Recovery Codes The bootblock recovery checkpoint codes are listed in order of execution: Checkpoint Code Description E0h The onboard floppy controller if available is initialized. Next, beginning the base 512 KB memory test. E1h Initializing the interrupt vector table next. E2h Initializing the DMA and Interrupt controllers next. E6h Enabling the floppy drive controller and Timer IRQs. Enabling internal cache memory.
Appendix B: BIOS POST Checkpoint Codes B-3 Uncompressed Initialization Codes The following runtime checkpoint codes are listed in order of execution. These codes are uncompressed in F0000h shadow RAM. Checkpoint Code Description 03h The NMI is disabled. Next, checking for a soft reset or a power on condition. 05h The BIOS stack has been built. Next, disabling cache memory. 06h Uncompressing the POST code next. 07h Next, initializing the CPU and the CPU data area.
H8DGU(-F) SERVERBOARD USER'S MANUAL Checkpoint Code Description 2Ah Bus initialization system, static, output devices will be done next, if present. See the last page for additional information. 2Eh Completed post-video ROM test processing. If the EGA/VGA controller is not found, performing the display memory read/write test next. 2Fh The EGA/VGA controller was not found. The display memory read/write test is about to begin. 30h The display memory read/write test passed.
Appendix B: BIOS POST Checkpoint Codes Checkpoint Code Description 52h The memory above 1 MB has been tested and initialized. Saving the memory size information next. 53h The memory size information and the CPU registers are saved. Entering real mode next. 54h Shutdown was successful. The CPU is in real mode. Disabling the Gate A20 line, parity, and the NMI next. 57h The A20 address line, parity, and the NMI are disabled. Adjusting the memory size depending on relocation and shadowing next.
H8DGU(-F) SERVERBOARD USER'S MANUAL Checkpoint Code Description 97h Initialization before the C800 adaptor ROM gains control has completed. The adaptor ROM check is next. 98h The adaptor ROM had control and has now returned control to BIOS POST. Performing any required processing after the option ROM returned control. 99h Any initialization required after the option ROM test has completed. Configuring the timer data area and printer base address next. 9Ah Set the timer and printer base addresses.