User`s manual

5-13
Chapter 5 Chassis Setup and Maintenance
Replacing a System Fans
Five heavy duty fans provide cooling for the chassis. These fans circulate air through
the chassis as a means of lowering the chassis' internal temperature. The SC836
Chassis includes three front fans and two rear fans.
SC836 chassis fans are fully hotswappable. In other words, fans may be removed
and replaced without having to power down the server.
5-7 Chassis Maintenance
Replacing Fans
Open the chassis and locate the faulty fan. Never run the server for an ex-1.
tended period of time with the chassis open.
Press the release tab on the fan and pull the fan upward.2.
Slide the new fan into the fan housing. Make sure the power connectors are 3.
correctly aligned. The new fan will be immediately active.
Figure 5-8: Chassis Fans
Front Fan (3 total) Rear Fan (2 total)
Fan Release Tab Fan Release Tab