User`s manual

C-7
SC747 Chassis Manual
Socket Settings
Socket Socket Setting Note
JP18 Connected to front panel
Buzzer reset*
Press once to disable buzzer
Press twice to enable buzzer
Fan Jumper Settings
Jumper Jumper Settings Note
JP61
1-2:Enabled
2-3:Disabled
FAN#1 enable/disable
JP97
1-2:Enabled
2-3:Disabled
FAN#1 selection for MG9072 chip
JP62
1-2:Enabled
2-3:Disabled
FAN#2 enable/disable
JP98
1-2:Enabled
2-3:Disabled
FAN#2 selection for MG9072 chip
JP63
1-2:Enabled
2-3:Disabled
FAN#3 enable/disable
JP99
1-2:Enabled
2-3:Disabled
FAN#3 selection for MG9072 chip
*The buzzer sound indicates that a condition requiring immediate attention has
occurred.
The buzzer alarm is triggered by the following conditions:
1. Hard drive failure
2. Fan failure
3. System temperature over 45º Celsius.
Fan Jumper Settings
This backplane can use up to three fans. To utilize each fan, you must congure
both jumpers as instructed below.