Installation Manual
| 
21
Gas Requirements 
Flexible Connections:
If the unit is to be installed with exible couplings and/or quick-
disconnect  ttings, the  installer  must  use  a  heavy-duty  AGA 
design-certied  exible  connector  or  at  least1/2”  (1.3  cm) 
ID NPT (with suitable strainreliefs) in compliance with ANSI 
Z21.41and Z21.69.
G - area for gas connection
E - area for electric connection
In Canada: CAN 1-6, 10-88 metal connectors for gas appliances 
and CAN 1-6.9 M79 quick disconnect devices for use with gas 
fuel.
In Massachusetts:This appliance must be installed with a 36” 
(3-foot) long exible gas connector.
GAS CONVERSION WARNING! 
Before carrying  out this  operation,  disconnect the  appliance 
from gas and electricity. Gas conversion shall be conducted by a 
factory-trained professional. Call the customer service hotline 
to identify a factory-trained professional near your home. The 
gas conversion procedure for this range includes 6 steps:
1. Pressure regulator
2. Surface burners 
3. Main oven burner 
4. Broiler burner 
5. Visual checks prior to closure of oven bottom panel 
6. Adjustment of minimum setting.
The conversion is not completed if all 6 steps have not been 
concluded  properly.  Before  performing  the  gas  conversion, 
locate the package containing the replacement nozzle shipped 
with every range. 
IMPORTANT: 
Each nozzle has a number  indicating its ow diameter printed 
on the body. Consult the table on “Specications Technical data 
“paragraph for matching nozzles to burners. Save the nozzles 
removed from the range for future use.
STEP1:PRESSURE REGULATOR 
The pressure regulator supplied with the appliance is a 
convertible type pressure regulator for use with Natural Gas at a 
nominal outlet pressure of 4” w.c. or LP gas at a nominal outlet 
pressure of 11” w.c. and it is pre arranged from the factory to 
operate with one of these gas/pressure as indicated in the labels 
afxed on the appliance, package and Instruction booklet. 
To convert the regulator for use with other liquid propane LP 
gas: 
1. Unscrew by hand the upper cap of 
the regulator, remove the white plastic 
attachment from the cap, reverse its direction 
and screw it again rmly against the cap. The 
white plastic attachment must be turned as 
follow for NATURAL GAS and as reversed 
for LP/PROPANE GAS
2. Screw by hand the metal cap in the original 
position on the regulator.
LP/PROPANE GAS
NATURAL GAS