Child Lock
Using your induction worktop
The child lock function can be enabled by turning the rst two
knobs from the left simultaneously into the left overwind position “ACC”. They need
to be hold in that position for a least 2s. The activation will be displayed on all 7 seg-
ment displays. If the knobs are not hold in the OWL position for long enough the CL
will not be enabled / displayed. If the CL function is active the cooking zones can not
be switched on even if the knobs are turned in a cooking level position other than
zero. The CL function has no working time limitation. A mains power failure which
exceeds the
specied hold-up time will deactivate the CL function. If at the event of a mains
power failure any knob is in a position different from zero no poweroutput will take
place. In order to deactivate the CL function repeat the same procedure as for activa-
ting. After unlocking all knobs
have to be turned back in the zero position (if any knob was in a position different
from zero). The control is then off and can be operated as expected.