Child Lock
Using your induction worktop
The child lock function can be enabled by turning the rst two
knobs from the left simultaneously into the left overwind position “ACC”. They need
to be hold in that position for a least 2s. The activation will be displayed on all 7 seg-
ment displays. If the knobs are not hold in the OWL position for long enough the CL
will not be enabled / displayed. If the CL function is active the cooking zones can not
be switched on even if the knobs are turned in a cooking level position other than
zero. The CL function has no working time limitation. A mains power failure which
exceeds the
specied hold-up time will deactivate the CL function. If at the event of a mains
power failure any knob is in a position different from zero no poweroutput will take
place. In order to deactivate the CL function repeat the same procedure as for activa-
ting. After unlocking all knobs
have to be turned back in the zero position (if any knob was in a position different
from zero). The control is then off and can be operated as expected.