Installation Guide
19 
461308462 07-2015
STEP 5: VISUAL CHECKS 
Before reinstalling the bottom panel, the 
following visual check must be performed 
to ensure that the conversion has been 
carried out properly and without damage 
to other components of the range.
OVEN IGNITER AND 
THERMOCOUPLE POSITION 
The appropriate gap between the tip of 
the spark plug or thermocouple and the 
burner shall be approximately 1/8’’.
The tip of the spark plug or 
thermocouple must fully overlap at 
least the rst gas emission hole of the
burner. After performing all these 
visual checks, reinstall the bottom
panel of the oven compartment and
proceed to setting the minimum for
each burner.
Gas Requirements 
STEP 6: MINIMUM 
FLAME ADJUSTMENT 
WARNING! These adjustments should 
be made only for use of the appliance 
with natural gas. For use with liquid 
propane gas, the By-pass screw must be 
fully turned in a clockwise direction. 
SURFACE BURNERS 
1. Light one burner at a time and set the 
knob to the MINIMUM position 
(small ame). 
2. Remove the knob. 
3. The range is equipped with a safety 
valve. Using a small size slotted 
screwdriver, locate the By-pass screw
valve on the valve body and turn it to 
the right or left until the burner ame
is adjusted to desired minimum. 
4. Make sure that the ame does not go 
out when switching quickly from the 
MAXIMUM to the MINIMUM position. 
For all hob burners
For simmer burners, on the tap in the right