User's Manual

ENFORCER Three- and Four-Channel RF Receiver
4 SECO-LARM U.S.A., Inc.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT
CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
Notice: The changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate
the equipment.
IMPORTANT NOTE: Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void
user’s authority to operate the device.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is
one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice.
SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2015 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the
written permission of SECO-LARM.
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606 Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: sales@seco-larm.com
Model
SK
-
910R3Q
SK
-
910R3
-
4Q
SK
-
910R4Q
SK
-
910R4
-
4Q
Operating frequency
315MHz
433.92MHz
315MHz
433.92MHz
Number of channels
3
3
4
4
Memory capacity
15 transmitte
r button codes per channel
Operating voltage
11~24 VAC/VDC
Operating current
Standby
12mA@12VDC
Active
50mA@12VDC per channel
Relay contact rating
Form C 10A@24VDC or 120VAC per channel
Connectors
Screw terminals, +,
-
, with NO/NC/COM per channel
Di
mensions
5.3”x3.9”x1.1” (135x100x27.5mm)
Sample Applications
:
Specifications
:
Compatible Transmitters
:
Operating frequency
315MHz
433.92MHz
Fixed Code: 68 billion codes
SK
-
919 Series Fixed Code
SK
-
939 Series Fixed Code
CODEBUMP™: 18 quintillion (1.8x10
19
) codes
SK
-
917 Series CODEBUMP
SK
-
937 Series CODEBUMP
Positive Output
COM
NC
NO
+
Positiv
e Power Source
Positive Power Output
Power for receiver
Negative Output
N.C. Application with Independent Power Sources
DC Power
Source
COM
NC
NO
+
AC Power
Source
N.O. Application with Independent Power Sources
COM
NC
NO
+
Typical N.C. Application
COM
NC
NO
+
E
-
941SA
-
1200
Electromagnetic Lock
Typical N.O. Application
SD
-
996C
-
NUQ
Electric Door Strike
DC Power
Source
AC Power
Source
E
-
941SA
-
1200
Electromagnetic Lock
SD
-
996C
-
NUQ
Electric Door Strike
COM
NC
NO
+
COM
NC
NO
+
Negative Power Source
Negative Power Output
Power for receiver
Order Part #
762
-
100
-
6
%
SK-910R3Q_R4Q_MuFcc_1504
PI
TSW1