Wiring Diagram Controller:
Connection Terminals
Terminals
Description
1
12~24 VDC
Connect to a 12~24VDC power supply.
Observe polarity.
2
GND (–)
3
Keypad PWR
Connect to keypad’s positive (+) terminal.
4
Data I/O
Connect to keypad’s Data I/O terminal.
5 Egress Input
N.O. Pushbutton contact to ground. Press
button to Activate output #1.
6
Doorbell Input
N.O. Doorbell contact to ground.
7 Duress Output
Transistor ground, max. 100mA@24VDC.
Triggers a silent alarm or other device when the
user enters a duress code.
8 Interlock Output
Transistor ground, max. 100mA@24VDC or
connect to Output #1. Inhibit of second keypad
if needed so that if one keypad is used to open
a door, the other is disabled.
9
Output #1
Inhibit
Output #1 inhibitor. N.O. input, connect to
Interlock Control of second keypad if needed so
that if one keypad is used to open a door, the
other is temporarily disabled.
10 Door Sensor
Connect to an optional N.C. sensor such as a
magnetic contact to monitor if a door is open or
closed. Connect to ground if not used.
11
GND ()
Common ground output.
12 Tamper
Tamper-switch output, N.C. contact, max.
50mA@24VDC. Connect to the N.C. 24-hour
protection zone of an alarm if needed.
13
Output 1
N.C.
Output #1, NO/NC/COM, relay output, max
5A@24VDC
14
COM
15
N.O.
16
Output 2
N.C.
Output #2, NO/NC/COM, relay output, max
1A@24VDC
17
COM
18
N.O.
19
Output 3
N.C.
Output #3, NO/NC/COM, relay output, max
1A@24VDC
20 COM
21
N.O.
22
Key Active
Output
Transistor ground max. 100mA@24VDC.
Switches to ground () for 10 seconds after any
button pressed.
23 Alarm Output
Transistor ground max. 100mA@24VDC.
Switches to ground when alarm output
activated, connect to an optional auxiliary alarm.
12~24V DC
GND (–)
KEYPAD PWR
DATA I/O
EG IN
DOORBELL IN
DU OUT
INT. LOCK
O/P 1 INHIB
DOOR SENS
TAMPER
N.C.
COM
N.O.
N.C.
COM
N.O.
N.C.
COM
N.O.
KEY ACT O/P
ALARM O/P
OUTPUT 3
OUTPUT 2
GND (–)
OUTPUT 1