User's Manual
ENFORCER Split Series Keypad with Proximity Card Reader
8 SECO-LARM U.S.A., Inc.
IMPORTANT NOTES:
IF USING THE KEYPAD WITH A MECHANICALLY OPERATED
DOOR OR GATE, MOUNT THE KEYPAD AT LEAST 15’ (5m)
FROM THE DOOR OR GATE TO PREVENT USERS FROM
BEING CRUSHED OR PINNED. FAILURE TO DO SO MAY
RESULT IN SERIOUS INJURY OR DEATH.
1. Always disconnect power before servicing the keypad. Do not apply power until all
connection wiring is completed.
2.
The keypad must be properly grounded. Use a minimum 22AWG wire connected to the
common ground output. Failure to do so may damage the keypad.
3.
All wiring and programming should be done by a professional installer to reduce the risk of
improper installation.
4.
The user’s guide for this keypad is located on page 35 of this manual. Be sure to store this
manual in a safe place for future reference.
Wiring Diagram – Keypad:
Connection Terminals
Terminals
Description
1
12~24 VDC
Connect to controller’s keypad power terminal.
2
Connect to controller’s GND (-) terminal.
3
Data I/O
Connect to controller’s Data I/O terminal.
4
Tamper N.C.
Tamper switch output, N.C. contact, max. 50mA@24VDC. Connect to N.C.
24-hour protection zone of an alarm if needed.
5
6
Aux LED
Connect to trigger the left green LED.
Jumper Settings
Jumper
Position
Description
Backlit
Full
Dim backlit during standby. Full backlit for 10 seconds after any button press.
Auto
No backlit during standby. Full backlit for 10 seconds after any button press.