User's Manual

ENFORCER Split Series Keypad with Proximity Card Reader
SECO-LARM U.S.A., Inc. 7
LED Indicators and Sounds:
Controller Sounds and LEDs
NOTE:
1. Keypad sounds can be programmed ON or OFF (see page 29).
2. Output relay activation sounds can be programmed ON or OFF (see page 29).
3. Amber LED flashing during standby mode can be programmed ON or OFF
(see page 30).
Status
Sounds
Amber LED (Center)
In programming mode
-
1 Flash/sec
In standby mode
-
1 Flash/sec
Power up delay
Continuous beeping for
5 seconds and doorbell
Continuous flashing
for 5 seconds
Egress delay warning
Continuous beeping
-
Door propped-open warning
Continuous beeping
-
Door forced-open warning
Continuous beeping and alarm output
-
Green/Red (Left)
Amber LED (Center)
Green/Red LED (Right)
Steady
Available for free
connection (Green)
Keypad locked (Red)
Output #1 inhibited (Red)
Programming mode
Output #1 activated (Green)
Output #2 activated (Red)
Flashing
Inhibit mode paused (Red)
Standby mode
-
Keypad Sounds and LEDs
LED IndicatorsKeypad
LED Indicators Controller
Amber LED
Flashing
Power-up mode
1 Flash per second
In standby or programming mode
Status
Sounds
(1)
Amber LED (Center)
In programming mode
-
Steady ON
Successful key entry
1 Beep
1 Flash
Successful code/card entry
2 Beeps
2 Flashes
Unsuccessful code/card entry
5 Beeps
5 Flashes
Power up delay
Continuous beeping for
1 minute
Continuous flashing for
1 minute
Output relay activation
(2)
1-Sec long beep
-
In standby mode
(3)
-
1 Flash/sec
System restore mode
2 Beeps
Fast flashing for 2.5 min
Code / card already stored
1 Long beep
-
Real time clock stopped after
power loss
Continuous 3 fast beeps
every 5 seconds
-
Keypad link-up with
controller failed
Continuous beep
every 1.5 seconds
-