User's Manual

ENFORCER Split Series Keypad with Proximity Card Reader
34 SECO-LARM U.S.A., Inc.
Direct Access to Programming (DAP):
Direct Access to Programming (DAP) is used to enter programming mode if the master code is
forgotten. DAP will not change the programming of the
SK-4131-SPSQ in any way.
To Use DAP:
1.
Disconnect the keypad’s power.
2.
Wait one minute to ensure that the keypad’s power is fully discharged.
3.
Reconnect the power. The keypad will beep repeatedly for one minute.
4.
While the keypad is beeping, move the DAP jumper to the ON position then back to the OFF
position once to stop the beeping.
5.
Enter the DAP code:

6.
The amber LED will turn ON, indicating that the keypad is
ready for a new master code to be
programmed.
NOTE:
See "Programming the Master Code" on page 17 for how to program a new master code.
Direct Access to Programming (DAP) will not reset the keypad’s programming. It will only
enter programming mode in order to program a new master code.