User's Manual
ENFORCER Split Series Keypad with Proximity Card Reader
SECO-LARM U.S.A., Inc. 33
Programming the Egress Delay/Warning/Alarm (continued):
NOTE: When the egress button is programmed to hold for a delay time before the door is
released, it is important to put a sign near the egress button to notify users of the
delay time.
Delay Time:
•
– No delay time (default): Output #1 operates immediately when the egress button is
pressed.
•
to –
Egress button delay time: The delay time can be set from 1 to 99 seconds. This
tells the keypad how long to wait after the egress button is pressed before activate output #1.
Examples:
1.
Momentary mode – Press the egress button, and the keypad and controller will beep for 5
seconds before output #1 activates:
2.
Hold the button to activate – Press and hold the egress button for 10 seconds, and the k
eypad
and controller will beep for those 10 seconds before output #1 activates:
3.
Return to default setting – Press the egress button to activate output #1 with no beeping or
delay:
NOTE:
For safety and to avoid confusion, when a delay or a press-and-
hold delay is programmed,
please post a notice near the egress button, such as "Press and hold the button for 5
seconds or until the door is unlocked."