User's Manual

ENFORCER Split Series Keypad with Proximity Card Reader
SECO-LARM U.S.A., Inc. 31
If the controller is connected to an optional magnetic contact or other door production switch or
device, The keypad can be programm
ed to beep when a door is propped open. This prompts
authorized users to close a door that was not closed properly or to investigate a door that may
have been deliberately propped open.
Door-propped-open warning OFF (default):

Door-forced-open warning ON:

NOTE:
 represents the delay time on the controller, which can be set from 1 to 999 seconds.
The delay time provides time for a door to close normally before triggering the door-propped-
open warning.
The door-propped-open beeping will stop when the open door is closed.
Programming the Door Open Alarm and Timing:
If the controller is connected to a magnetic contact or other door monitoring device, the controller
can be programmed to trigger the alarm output and sire
n for 1 to 999 seconds if the door is
opened. In this case, if the alarm output is triggered, the output either automatically ends at the
end of the programmed time or when a user code or super user code is input for output #1.
NOTE:
If programmed for the door open alarm, the alarm output and siren will activate for the
programmed time when the door is forced open or opened with the egress input. There is no
alarm output activation if the door is opened with a valid user code and/or card.
The door open alarm and door-forced-open warning should not both be enabled, as the
overlap in timing could result in incorrect alarm output (see "Programming the Door-Forced-
Open Warning and Timing on page 30).
To Program:
Door open alarm OFF (default):

Door open alarm ON:

NOTE:
 represents the alarm output time, which can be set from 1 to 999 seconds.
Programming the Door-Propped-Open Warning and Delay Time: