The keypad’s amber LED typically flashes while the keypad is in standby mode, but can be
programmed off if needed.
Enable amber LED flashing during standby mode (default):

Disable amber LED flashing during standby mode:

Programming the Door-Forced-Open Warning and Timing:
If the controller is connected to an optional magnetic contact or other door protection switch or
device, the keypad and controller can be programmed to beep when a door has b
een forced open.
The controller will also activate the alarm output and siren. The beep, siren, and alarm output can
be set to activate for 1 to 999 seconds.
Door-forced-open warning OFF (default):

Door-forced-open warning ON:

NOTE:
 represents the beep, siren, and alarm output active time, which can be set from 1 to
999 seconds.
If programmed for door-forced-open warning, the keypad will beep and the controller will
activate the alarm output and siren for the programmed time if the door is forced open without
using a user code and/or card or the egress button. The controller will also beep until the door
is closed. There will be no output sounds or alarm output activation if the door is opened with
a user code and/or card or the egress button.
The door-forced-open warning and the door open alarm should not both be enabled, as the
overlap in timing could result in incorrect alarm outputs (see "Programming the Door Open
Alarm and Timing on page 31).