User's Manual
ENFORCER Split Series Keypad with Proximity Card Reader
SECO-LARM U.S.A., Inc. 3
Programming Instructions
Follow the instructions bellow if the following covers your needs.
•
A new master code.
•
A single 4-digit user code for all users, and no proximity cards
•
One output to unlock a door.
•
A 3-second delay time in opening the door after the output is activated.
This page is for installers looking to do a basic installation and programming of the keypad. For
more in
-depth installation and programming instructions, see the Table of Contents on page 4.
Programming Tips
•
The master, super user, common user, visitor, duress, and user codes cannot be the
same.
•
A flashing amber LED indicates the keypad is in standby mode. A solid amber LED indicates
the keypad is in programming mode.
•
If the keypad is set for Auto Code Entry Mode, all codes will need to be the
same number of
digits as the master code (see page 28).
1. Power on the keypad and controller.
2. Turn off the beeping before the 1-minute power-up period ends:
3. Move the link-up jumper to the ON position.
4. Enter Programming Mode:
NOTE:
is the default master code.
5. Change the master code:
NOTE: is the new master code.
6. Set the user code to operate output #1 (unlock the door):
NOTE:
chooses user ID #000 of 1,000 possible users (000~999).
is the new user code for user ID #000.
7. Set the output #1 delay time (skip this step if the default value of 5 seconds is
acceptable):
NOTE:
sets the output #1 delay time for 3 seconds.
8. Exit Programming Mode:
9. Move the link-up jumper to the OFF position.
NOTE: The link-up procedure must be done during initial programming and any time
a. the master code is changed.
Quick Programming Guide: