User's Manual

ENFORCER Split Series Keypad with Proximity Card Reader
SECO-LARM U.S.A., Inc. 27
Programming the Output #1 Auto-Disable Time (continued):
If the programmed start time is before the end time, output #1 is auto-disabled
within a single day. If the programmed start time is after the end time, the end time
will be on the following day.
The start time and end time cannot be the same.
The auto-disable time can be temporarily paused and restarted using the super user code
(see "Programming the Super User Code" on pages 18~19).
During the output #1 auto-disable time, the super user code can be used to
operate output #1.
The keypad’s left LED will remain red during the output #1 auto-disable time.
When programming the output
#1 auto-disable time, use this general formula:

 Program Output #1 Auto-Disable Time
Start Time
End Time
Start Time:
Start time for output #1 auto-disable time.  represents hours and  represents
minutes in the military (24-hour) time format, 00:00 to 23:59.
End Time:
End time for output #1 auto-disable time.  represents hours and  represents
minutes in the military (24-hour) time format, 00:00 to 23:59.
Examples
:
In these examples, assume that the sup
er user code is .
1.
In programming mode, set the output #1 auto-disable from 12:00 PM to 1:00 PM:

2.
In programming mode, set the output #1 auto-disable time from 6:30 PM to 7:30 AM the
following day:

3.
In programming mode, clear the output #1 auto-disable time:

4.
Temporarily pause and resume the output #1 auto-disable time:

5.
Activate output #1 during the auto-disable time (i.e. open the protected door):
