Programming the Output Mode and Output Timing:
The relays for outputs #1, #2, and #3 can be programmed to trigger ON and OFF with a user code
or user card (toggle mode), or to trigger for a programmed length of time of up to nearly 28 hours
before automatically turning OFF. The toggle or timed outputs can be used for locking or
unlocking a door for
a variety of functions that can be controlled with the keypad.
When programming the output mode and time, use this general formula:

Output
Output Mode and Time
Outputs:
Output #1
Output #2
Output #3
Output Mode and Time:
Start/stop (toggle) mode. In this case, the output starts when a user code and/or user
card is entered, and stops when a user code and/or card is entered.
to The output triggered by a user code and/or user card lasts 1 to
99,999 seconds (nearly 28 hours) before automatically turning off (default 5 seconds).
NOTE:
While the keypad is in momentary timed output mode, th
e output can be reset at any time
by entering the super user code.