User's Manual

ENFORCER Split Series Keypad with Proximity Card Reader
12 SECO-LARM U.S.A., Inc.
Door Auto RelockThe system will immediately
relock the door after the door is closed. This
prevents unwanted "tailgate" entries, which can
happen if an unauthorized person tries to follow an
authorized person through the door.
Interlock ControlWhen the door is open, the
Interlock Output will give a (-) ground command to
disable the other keypad in an interlock system
Door Forced-Open Warning The keypad will
beep and the controller will beep, activate the
alarm output, and activate the siren whenever the
door is forced open without using a valid user
code. See "programming the Door-Forced Open
Warning and Timing" on page 30.
Door Propped-Open Warning The keypad will
beep whenever the door is open longer than the
programmed time. See "Programming the Door-
Propped-Open Warning and Timing" on page 31.
Door Open AlarmThe controller will activate the
alarm output and siren whenever the door is
opened. See "Programming the Door Open Alarm
and Timing" on page 31.
The Alarm Output switches to () ground in door forced to open or the door open after Egress
Delay. You may use it to turn ON an LED lamp and/ or a small buzzer to notify a guard; or
connect it to a 24 hour Normally Open protection zone of an alarm system. See "Programming
the Door-Forced-Open Warming and Timing" and "Programming the Door Open Alarm and
Timing" on pages 30~31.
NOTE: Only one connection option is recommended. Make sure that the sink current does not
exceed the maximum rating of 100mA.
2211 23
2211 23
Sample Applications for Auxiliary Terminals:
With the help of a Normally Closed
door position sensor (usually a
magnetic door switch) on the door
to set up the following functions:
Door Sensor:
Alarm Output: