User's Manual

ENFORCER Split Series Keypad with Proximity Card Reader
SECO-LARM U.S.A., Inc. 11
Common Ground
Egress button
Door bell
button
Egress button
Digital KeypadDigital Keypad
Door bell
button
Door 1
sensing
Door 2
sensing
Cross wire connection for inter-lock functions
Sample Applications (continued):
In this application, two keypads are each connected to separate door locks and egress
pushbuttons. While one door is open, the other ca
nnot be opened.
Use an N.C. magnetic contact or some other N.C. device to detect whether a door is opened
or closed. Do this for the two doors being protected.
Interlock system using two Split-Series Keypads:
An interlock system needs two door controllers. This application example uses two keypad
systems with simple cross wire connection on their
"Output 1 Inhibit" and "Interlock Control
O
utput" terminals. It is necessary to link up the "(–) GND" terminals of the two keypads as
common ground to achieve the inter
-lock functions.
Use keypad to open the door from outside
Press egress button to open the door from inside
Connect the door magnetic sensors on the doors to monitor their positions
While door 1 is open, door 2 cannot be opened, and vice versa