LEED SCORECARD
LEED Programme
Certifcation
Category Credit Title LEED Points Attainable Credit Description
How our product contributes
to obtaining LEED points
Indoor Environmental
Quality
Credit 1: Enhanced Indoor Air Quality
Strategies – Option 2 Additional Enhanced
IAQ Strategie - option D
1 point ID&C,
2 points Retail CI
To reduce concentrations of chemical that can damage air
quality, human health, productivity, and the environment.
1. Formaldehyde emission are less than
0.05mg/m3, TVOCs are less than 0.5mg/m3.
2. The product is GreenGuard Gold certified.
Credit 2: Low-Emitting Materials – Option1
Flooring
1 point
1. VOC emission are less than 0.5mg/m3.
2. The products is GreenGuard Gold certified.
Credit 4: Indoor Air Quality Assessment -
Option 2 Air Testing
2 points To establish better quality indoor air in the building
1. Formaldehyde emission are less than
0.05mg/m3, TVOCs are less than 0.5mg/m3.
2. The product is GreenGuard Gold certified.
Material & Resource
Credit 3: sourcing of raw material - Recycled
Content – Option 2
1 point
Increase demand for building products that incorporate
recycled content materials
The products has a Natural Cork Underlay pre
attached. Natural cork underlay contains at
least 95% pre-consumer content
Credit 4: Material ingredient– Option 2 1 point Minimize the use and generation of harmful substances The product is 100% REACH compliant
Credit 6 – PBT source reduction: lead,
cadmium and copper
1 point
To reduce the release of persistent, bioaccumulative, and toxic
chemicals
The product is free of lead, cadmium and
copper
Material & Resource
Credit 3: Purchasing - Facility maintenance
and renovation
1 point
To reduce the environmental harm from materials used in
building renovations
1. The product is 100% REACH compliant
2. Formaldehyde emission are less than
0.05mg/m3, TVOCs are less than 0.5mg/m3. 3.
Test repost according to ISO 16000 is available
on request.
3. The product is GreenGuard Gold certified.
Indoor Environmental
Quality
Credit 2: Contaminant Control – Option 4
Air Testing
1 point
Demonstrate that contaminants do not exceed concentration
levels listed
The products is GreenGuard Gold certified.
Credit 7: Low-Emitting Materials 0.5 point
To reduce occupants’ exposure to airborne chemical
contaminants
The product is GreenGuard Gold certified and
meet the requirements of CA Section 01350.
The product is made with ULEF or non-added
formaldehyde material
Material & Resource Prerequiste – Durability management 0 point (Prerequiste) To promote durability and performance of the building The product is water resistant
Indoor Environmental
Quality
Credit 1: Enhanced Indoor Air Quality
Strategies – Option 2 Additional Enhanced
IAQ Strategies - option D
1 point ID&C,
2 points Retail CI
To reduce concentrations of chemical contaminants that can
damage air quality, human health, productivity, and the
environment.
1. Formaldehyde emission are less than
0.05mg/m3, TVOCs are less than 0.5mg/m3.
2. The product is GreenGuard Gold certified.
Credit 2: Low-Emitting Materials – Option1
Flooring
1 point
1. VOC emission are less than 0.5mg/m3.
2. The products is GreenGuard Gold certified.
Credit 4: Indoor Air Quality Assessment -
Option 2 Air Testing
2 points To establish better quality indoor air in the building
1. Formaldehyde emission are less than
0.05mg/m3, TVOCs are less than 0.5mg/m3.
2. The product is GreenGuard Gold certified.
Credit 9: Acoustic Performance 2 points To provide workspaces and classrooms effective acoustic design
The product has a high acoustic performance.
Material & Resource Credit 4: Material ingredient– Option 2 1 point Minimize the use and generation of harmful substances The product is 100% REACH compliant
WELL SCORECARD
Facet Feature Part Requirements Concept score
How our product contribute
to obtain WELL level certification
AIR
01. Air quality standards 1. Standards For Volatile Substances
The following conditions are met:
a. Formaldehyde levels less than
27ppb (0.027ppm)
b. Total volatile organic compounds
less than 500ug/m3 (0.5mg/m3)
PRECONDITION
a. Formaldehyde emission are less than
0.05mg/m3.
b. The total volatile organic compounds are
less than 0.5mg/m3.
04. VOC Reduction 1. Interior Paints and Coatings
The VOC limits of newly applied
paints and coating meet one of the
following requirements:
a. 100% of installed products meet
California Air Resources Board
(CARB) 2007, Suggested Control
Measure (SCM) for Architectural
Coatings, or South Coast Air Quality
Management District (SCAQMD)
Rule 1113, effective June 3, 2011 for
VOC content.
b. At minimum 90%, by volume,
meet the California Department of
Public Health (CDPH) Standard
Method v1.1-2010 for VOC
emissions
PRECONDITION
a. The VOC limits for California Air Resources
Board (CARB) are less than 0.11ppm.
b. Measured Concentration of Total Volatile
Organic Compounds (TVOC): Less than/equal
to 0.5 mg/m3 (in compliance with CDPH/EHLB
Standard Method v1.1-2010).
The product is GreenGuard Gold certified
3. Flooring
The VOC emissions of all newly
installed flooring must meet all limits
set by the following, as applicable:
a. California Department of Public
Health (CDPH) Standard Method
v1.1-2010.
PRECONDITION
Conforms to the CDPH/EHLB Standard Method
v1.1-2010 (California Section 01350), effective
January 1, 2012, for the school classroom and
private office parameters when modeled as
Flooring.
The product is GreenGuard Gold certified
11. Fundamental Material
Safety
1. Asbestos and Lead Restriction
All newly-installed building materials
meet the following materials
composition requirements:
a. No asbestos.
b. Not more than 100 ppm (by
weight) added lead.
PRECONDITION
a. No asbestos
b. The product contain less than 100 ppm.
2. Lead Abatement
For repair, renovation or painting on
buildings constructed prior to any
applicable laws banning or
restricting lead paint, lead
evaluation and abatement.
PRECONDITION The product contain less than 90 ppm.
3. Asbestos Abatement
To reduce hazards in buildings
constructed prior to any applicable
laws banning or restricting asbestos,
the following testing, evaluation and
abatement.
PRECONDITION The product contain less than 90 ppm.
25. Toxic Material
Reduction
2. Flame Retardant Limitation
Halogenated flame retardants are
limited in the following components
to 0.01% (100 ppm) to the extent
allowable by local code:
a. Window and waterproofing
membranes, door and window
frames and siding.
b. Flooring, ceiling tiles and wall
coverings.
c. Piping and electrical cables,
conduits and junction boxes.
d. Sound and thermal insulation.
e. Upholstered furniture and
furnishings, textiles and fabrics.
OPTIMIZATION
The product don't contain halogenated flame
retardants
The WELL Building Standard is founded on the understanding that facets of our environment interact with personal, genetic and behavioral factors to shape our overall health and well-being. By compiling leading practices in building design
LEED was developed to address all buildings everywhere, regardless of where they are in their life cycle. From hospitals to data centers, from historical buildings to those still in the design phase, there is a LEED certification programm for
Page 2 of 3