SUPER ® SUPERSERVER 6015B-3 SUPERSERVER 6015B-T USER’S MANUAL 1.
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com.
Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6015B-3/6015BT. Installation and maintenance should be performed by experienced technicians only.
SUPERSERVER 6015B-3/6015B-T User's Manual Chapter 4: System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6015B-3/6015B-T. Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X7DBR-3/X7DBR-E serverboard, including the locations and functions of connections, headers and jumpers.
Preface Notes v
SUPERSERVER 6015B-3/6015B-T User's Manual Table of Contents Preface About This Manual ...................................................................................................... iii Manual Organization ................................................................................................... iii Chapter 1: Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features ..................
Table of Contents Chapter 4: System Safety 4-1 Electrical Safety Precautions .......................................................................... 4-1 4-2 General Safety Precautions ........................................................................... 4-2 4-3 ESD Precautions ............................................................................................ 4-3 4-4 Operating Precautions ....................................................................................
SUPERSERVER 6015B-3/6015B-T User's Manual ATX PS/2 Keyboard and PS/2 Mouse Ports ......................................... 5-16 Overheat LED ........................................................................................ 5-16 Wake-On-LAN ........................................................................................ 5-17 Wake-On-Ring ........................................................................................ 5-17 SMB ............................................................
Table of Contents Chapter 7: BIOS 7-1 Introduction ..................................................................................................... 7-1 7-2 Running Setup ................................................................................................ 7-2 7-3 Main BIOS Setup ............................................................................................ 7-2 7-4 Advanced Setup ............................................................................................
SUPERSERVER 6015B-3/6015B-T User's Manual Notes x
Chapter 1: Introduction Chapter 1 Introduction 1-1 Overview The SuperServer 6015B-3/6015B-T is a high-end server comprised of two main subsystems: the SC815TQ-560 1U server chassis and the X7DBR-3/X7DBR-E dual processor serverboard. Please refer to our web site for information on operating systems that have been certified for use with the SuperServer 6015B-3/6015B-T (www.supermicro.com).
SUPERSERVER 6015B-3/6015B-T User's Manual SuperServer 6015B-3/6015B-T User's Manual Note: the "V" and "B" at the end of a server name (e.g. 6015B-3V or 6015B-3B) denotes the chassis color. V is for silver and B is for black. 1-2 Serverboard Features At the heart of the SuperServer 6015B-3/6015B-T lies the X7DBR-3/X7DBR-E, a dual processor serverboard based on Intel's 5000P chipset. Below are the main features of the X7DBR-3/X7DBR-E (see Figure 1-1 for a block diagram of the chipset).
Chapter 1: Introduction must have RAID support to enable the hot-swap capability and RAID function of the Serial ATA drives. PCI Expansion Slots The X7DBR-3/X7DBR-E has two Universal PCI slots, each of which support either one x8 PCI-Express card or one PCI-X 133/100 MHz card. One standard size expansion card and one low profile expansion card (with their appropriate riser cards) may be used with the server. See Section 5-6 for details.
SUPERSERVER 6015B-3/6015B-T User's Manual SAS/SATA Subsystem The SC815TQ-560 chassis was designed to support four SAS (6015B-3) or SATA (6015B-T) hard drives, which are hot-swappable units. Note: The operating system you use must have RAID support to enable the hot-swap capability of the SAS/SATA drives. PCI Expansion Slots One standard size and one low-profile PCI-X/PCI-E add-on card may be used with the SC815TQ-560 chassis. See section 5-6 for details.
Chapter 1: Introduction Figure 1-1. Intel 5000P Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. ATA100 ESI EXP.BUS PORT #1,2 J9 #4 VGA ES1000 PCI-X100 IDE CONN #5 #4 #3 #2 #1 #0 ESB2 3.0Gb/S PCIX #5 #4 #3 #2 #1 #0 PCI-33 USB2.
SUPERSERVER 6015B-3/6015B-T User's Manual 1-4 Contacting Super Micro Headquarters Address: Tel: Fax: Email: Web Site: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. +1 (408) 503-8000 +1 (408) 503-8008 marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) www.supermicro.com Europe Address: Tel: Fax: Email: Super Micro Computer B.V.
Chapter 2: Server Installation Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your SuperServer 6015B3/6015B-T up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc.
SUPERSERVER 6015B-3/6015B-T User's Manual Choosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). - Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing. - This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
SUPERSERVER 6015B-3/6015B-T User's Manual 2-4 Installing the System into a Rack This section provides information on installing the 6015B-3/6015B-T into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
Chapter 2: Server Installation Installing the Outer Rails Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail. Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack.
SUPERSERVER 6015B-3/6015B-T User's Manual Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-3.
Chapter 2: Server Installation Installing the Server into a Telco Rack To install the SuperServer 6015B-3/6015B-T into a Telco type rack, use two Lshaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it.
SUPERSERVER 6015B-3/6015B-T User's Manual 2-5 Checking the Serverboard Setup After you install the 6015B-3/6015B-T in the rack, you will need to open the top cover to make sure the serverboard is properly installed and all the connections have been made. 1. Accessing the inside of the System (see Figure 2-5) First, grasp the two handles on either side and pull the system straight out until it locks (you will hear a "click").
Chapter 2: Server Installation Figure 2-5.
SUPERSERVER 6015B-3/6015B-T User's Manual 2-6 Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the SAS/SATA drives and SAS/SATA backplane have been properly installed and all connections have been made. 1. Accessing the drive bays All drives are accessable from the front of the server. For servicing the DVDROM and floppy drives, you will need to remove the top chassis cover.
Chapter 3: System Interface Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the SAS/SATA drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components. There are also two buttons on the chassis control panel and an on/off switch on the power supply. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
SUPERSERVER 6015B-3/6015B-T User's Manual 3-3 Control Panel LEDs The control panel located on the front of th SC815TQ-560 chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take. Overheat/Fan Fail: When this LED flashes it indicates a fan failure.
Chapter 3: System Interface Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating. 3-4 Drive Carrier LEDs SAS Drives (6015B-3) Each SAS drive carrier has two LEDs: Green: When illuminated, the green LED on the front of the SAS drive carrier indicates drive activity. A connection to the backplane enables this LED to blink on and off when that particular drive is being accessed.
SUPERSERVER 6015B-3/6015B-T User's Manual Notes 3-4
Chapter 4: System Safety Chapter 4 System Safety 4-1 Electrical Safety Precautions ! Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 6015B-3/6015B-T from damage: Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system.
SUPERSERVER 6015B-3/6015B-T User's Manual Serverboard Battery: CAUTION - There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarities (see Figure 4-1). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. DVD-ROM Laser: CAUTION - this server may have come equipped with a DVD-ROM drive.
Chapter 4: System Safety After accessing the inside of the system, close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made. 4-3 ESD Precautions ! Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic components and printed circuit boards.
SUPERSERVER 6015B-3/6015B-T User's Manual 4-4 Operating Precautions ! Care must be taken to assure that the chassis cover is in place when the 6015B3/6015B-T is operating to ensure proper cooling. Out of warranty damage to the 6015B-3/6015B-T system can occur if this practice is not strictly followed. Figure 4-1.
Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X7DBR-3/X7DBR-E serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter. Remember to close the chassis completely when you have finished working on the serverboard to protect and cool the system sufficiently.
SUPERSERVER 6015B-3/6015B-T User's Manual 5-2 Processor and Heatsink Installation When handling the processor, avoid placing direct pressure on the label ! area of the fan. Also, do not place the serverboard on a conductive surface, which can damage the BIOS battery and prevent the system from booting up. IMPORTANT! Always connect the power cord last and remove it first before adding, removing or changing any hardware components.
Chapter 5: Advanced Serverboard Setup 3. Use your thumb and your index finger to hold the CPU at opposite sides. 4. Align pin1 of the CPU (the corner marked with a triangle) with the notched corner of the CPU socket. 5. Find the corner of the CPU that has a semi-circle cutout below a gold Gold dot Socket key dot (CPU key). This corner should be aligned with the cutout on the socket (socket key). CPU key 6. Once aligned, carefully lower the CPU straight down into the socket.
SUPERSERVER 6015B-3/6015B-T User's Manual Installing the Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the (preinstalled) heatsink retention mechanism. 3. Screw in two diagonal screws (i.e. the #1 and the #2 screws) until just snug. Do not fully tighten the screws or you may damage the CPU.) 4.
Chapter 5: Advanced Serverboard Setup 5-3 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The ribbon cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back.
SUPERSERVER 6015B-3/6015B-T User's Manual Connecting the Control Panel JF1 contains header pins for various front control panel connectors. See Figure 5-1 for the pin locations of the various front control panel buttons and LED indicators. Please note that even and odd numbered pins are on opposite sides of each header. All JF1 wires have been bundled into single keyed ribbon cable to simplify their connection. The red wire in the ribbon cable plugs into pin 1 of JF1.
Chapter 5: Advanced Serverboard Setup 5-4 I/O Ports The I/O ports are color coded in conformance with the PC 99 specification. See Figure 5-2 below for the colors and locations of the various I/O ports. Figure 5-2. Rear Panel I/O Ports Note: the external SAS port is included on the 6015B-3 only. 5-5 Installing Memory Note: Check the Supermicro web site for recommended memory modules. CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage.
SUPERSERVER 6015B-3/6015B-T User's Manual Memory Support The X7DBR-3/X7DBR-E supports up to 32 GB of ECC FBD (Fully Buffered DIMM) DDR2-667 or DDR2-533 SDRAM. The memory is an interleaved configuration, which requires modules of the same size and speed to be installed in pairs. You should not mix DIMMs of different sizes and speeds. See Figure 5-3 for installing and removing memory modules. Figure 5-3a.
Chapter 5: Advanced Serverboard Setup 5-6 Adding PCI Cards 1. PCI Expansion Slots The X7DBR-3/X7DBR-E has two Universal PCI slots, each of which support either one x8 PCI-Express card or one PCI-X 133/100 MHz card. (On the X7DBR-3, slot #7 is a 100 MHz PCI-X slot, on the X7DBR-E slot #7 is a 133 MHz PCI-CX slot.) The SC815TQ-560 chassis can accommodate one standard size (full height full length) and one low profile PCI expansion cards.
SUPERSERVER 6015B-3/6015B-T User's Manual 5-7 Serverboard Details Figure 5-4.
Chapter 5: Advanced Serverboard Setup X7DBR-3/X7DBR-E Quick Reference Jumper Description Default Setting J3P 3rd Power Fail Detect Open (Disabled) JBT1 CMOS Clear (See Section 5-9) JCF1 JI2C1/JI2C2 Compact Flash Master/Slave Select SMB to PCI Closed (Master) Open (Disabled) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPS1* JPL1/ JPL2 SAS Enable/Disable JLAN1/JLAN2 Enable/Disable Pins 1-2 (Enabled) Pins 1-2 (Enabled) JWD Watch Dog Pins 1-2 (Reset) Connector Description COM1/COM2 FAN 1-
SUPERSERVER 6015B-3/6015B-T User's Manual 5-8 Connector Definitions ATX Power 20-pin Connector Pin Definitions (JPW1) ATX Power Connector Pin# Definition Pin # Definition 11 GND8 1 GND1 The primary ATX power supply con- 12 +5V1 2 GND2 nector meets the SSI (Superset ATX) 13 +5V2 3 GND3 14 3.3V1 4 GND4 15 3.3V2 5 GND5 16 +5V/SB 6 GND6 17 +12V4 7 GND7 18 +12V5 8 +12V1 19 +12V6 9 +12V2 20 Blcoked 10 +12V3 20-pin specification.
Chapter 5: Advanced Serverboard Setup HDD LED HDD LED Pin Definitions (JF1) The HDD (IDE Hard Disk Drive) LED Pin# Definition connection is located on pins 13 and 13 Vcc 14 of JF1. Attach the IDE hard drive LED cable to display disk activity. 14 HD Active Refer to the table on the right for pin definitions. NIC1 LED The NIC1 (Network Interface Controller) LED connection is located on pins 11 and 12 of JF1. Attach the NIC1 LED cable to display network activity.
SUPERSERVER 6015B-3/6015B-T User's Manual Power Fail LED Power Fail LED Pin Definitions (JF1) The Power Fail LED connection is Pin# Definition located on pins 5 and 6 of JF1. Re- 5 Vcc fer to the table on the right for pin definitions. 6 Ground Reset Button Reset Button Pin Definitions (JF1) The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to the hardware reset switch on the computer case. Refer to the table on the right for pin definitions.
Chapter 5: Advanced Serverboard Setup Serial Ports Serial Port Pin Definitions (COM1, COM2) The COM1 serial port is located on Pin # Definition Pin # Definition the IO backplane. COM2 is a header 1 DCD 6 DSR on the serverboard (see serverboard layout for location). See the table on 2 RXD 7 RTS 3 TXD 8 CTS the right for pin definitions. 4 DTR 9 RI 5 Ground 10 NC Note: Pin 10 is included on the header but not on the port. NC indicates no connection.
SUPERSERVER 6015B-3/6015B-T User's Manual Universal Serial Bus Headers Universal Serial Bus Headers Pin Definitions (JUSB2, JUSB3) Four additional USB headers (at JUSB2 and JUSB3) are included on the serverboard. These may be used for front side access. A USB cable (not included) is needed for the connection. See the table on the right for USB2 Pin # Definition USB3, USB4 Pin # Definition 1 +5V 1 +5V 2 PO- 2 PO- 3 PO+ 3 PO+ 4 Ground 4 Ground 5 Key 5 NC pin definitions.
Chapter 5: Advanced Serverboard Setup Wake-On-LAN Wake-On-LAN Pin Definitions (JWOL) The Wake-On-LAN header is designated JWOL. See the table on the right for pin definitions. You must enable the LAN Wake-Up setting in BIOS to use this feature. You must Pin# Definition 1 +5V Standby 2 Ground 3 Wake-up also have a LAN card with a Wakeon-LAN connector and cable. Wake-On-Ring Wake-On-Ring Pin Definitions (JWOR) The Wake-On-Ring header is designated JWOR.
SUPERSERVER 6015B-3/6015B-T User's Manual JLAN1/2 (Ethernet Ports) Two Ethernet ports (designated JLAN1 and JLAN2) are located beside the VGA port on the I/O backplane. These ports accept RJ45 type cables. Alarm Reset (JAR) The system will notify you in the event Alarm Reset Pin Definitions (JAR) of a power supply failure. This feature assumes that Supermicro redundant power supply units are installed in the chassis. Connect a microswitch to the JAR header to disable the power supply fail alarm.
Chapter 5: Advanced Serverboard Setup 5-9 Jumper Settings Explanation of Jumpers To modi f y the operat ion of the serverboard, jumpers can be used 3 2 1 3 2 1 Connector Pins to choose between optional settings. Jumpers create shorts between two Jumper pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit Setting board. See the diagram at right for an example of jumping pins 1 and 2.
SUPERSERVER 6015B-3/6015B-T User's Manual 3rd Power Supply Fail Detect Enable/Disable 3rd Power Supply Fail Detect Enable/Disable Jumper Settings (J3P) The system can notify you in the event Jumper Setting of a power supply failure. This feature Open Disabled Closed Enabled assumes that three power supply units are installed in the chassis with one act- Definition ing as a backup.
Chapter 5: Advanced Serverboard Setup SAS Controller Enable (6015B-3 only) SAS Controller Enable Jumper Settings (JPS1) JPS1 enables or disables the Adapt- Jumper Setting Definition ec 9140W SAS controller on the Pins 1-2 Enabled serverboard. See the table on the right for jumper settings. The default Pins 2-3 Disabled setting is enabled.
SUPERSERVER 6015B-3/6015B-T User's Manual 5-11 Floppy, IDE, SATA and SAS Drive Connections Note the following when connecting the floppy and hard disk drive cables: • The floppy disk drive cable has seven twisted wires. • A red mark on a wire typically designates the location of pin 1. • A single floppy disk drive ribbon cable has 34 wires and two connectors to provide for two floppy disk drives.
Chapter 5: Advanced Serverboard Setup IDE Connectors IDE Drive Connectors Pin Definitions (JIDE1, JIDE2) There are no jumpers to con- Pin# Definition figure the onboard IDE1 and 1 Reset IDE 2 Ground IDE2 connectors. See the table on the right for pin defini- 3 Host Data 7 4 Host Data 8 5 Host Data 6 6 Host Data 9 tions.
SUPERSERVER 6015B-3/6015B-T User's Manual SAS Ports (X7DBR-3 only) There are eight Serial Attached SCSI ports on the motherboard (SAS0~3 and SAS4~7). See the tables on the right for pin definitions.
Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC815TQ-560 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step. Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver.
SUPERSERVER 6015B-3/6015B-T User's Manual Figure 6-1. Chassis: Front and Rear Views Slim DVD-ROM Drive Slim Floppy Drive (optional) SAS/SATA Drive Bays Power Supply Module Mouse/Keyboard USB Ports COM1 Port System LEDs System Reset Control Panel Main Power PCI Expansion Slots (w/ riser cards) Ethernet Ports VGA Port SAS Port Note: the external SAS port is included on the 6015B-3 only.
Chapter 6: Advanced Chassis Setup 6-3 System Fans Four 40-mm heavy duty counter-rotating fans provide the cooling for the SuperServer 6015B-3/6015B-T. Each fan unit is actually made up of two fans joined back-toback, which rotate in opposite directions. This counter-rotating action generates exceptional airflow and works to dampen vibration levels.
SUPERSERVER 6015B-3/6015B-T User's Manual Figure 6-2. System Cooling Fans 6-4 Drive Bay Installation/Removal Removing the Front Bezel If your system has a front bezel (optional) attached to the chassis, you must first remove it to gain access to the drive bays. To remove the bezel, first unlock the front of the chassis then press the release knob (see Figure 6-3). Carefully remove the bezel with both hands. A filter located within the bezel can be removed for replacement/cleaning.
Chapter 6: Advanced Chassis Setup Figure 6-3. Removing the Front Bezel 1. Unlock 2. Press release knob 3. Remove bezel assembly Accessing the Drive Bays SAS/SATA Drives: Because of their hotswap capability, you do not need to access the inside of the chassis or power down the system to install or replace SAS or SATA drives. Proceed to the next section for instructions.
SUPERSERVER 6015B-3/6015B-T User's Manual SAS/SATA Drive Installation 1. Mounting a SAS/SATA drive in a drive carrier The SAS/SATA drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airflow for the drive bays. For this reason, even empty carriers without drives installed must remain in the chassis.
Chapter 6: Advanced Chassis Setup 2. Installing/removing hot-swap SAS/SATA drives The SAS/SATA drive carriers are all easily accessible at the front of the chassis. These hard drives are hot-pluggable, meaning they can be removed and installed without powering down the system. To remove a carrier, push the release button located beside the drive LEDs. Then swing the colored handle fully out and use it to pull the unit straight out (see Figure 6-5).
SUPERSERVER 6015B-3/6015B-T User's Manual DVD-ROM and Floppy Drive Installation The top cover of the chassis must be opened to gain full access to the DVD-ROM and floppy drive bays. The 6015B-3/6015B-T accomodates only slim-line DVDROM drives. Side mounting brackets are needed to mount a slim-line DVD-ROM drive in the 6015B-3/6015B-T server. You must power down the system before installing or removing a floppy or DVDROM drive. First, release the retention screws that secure the server unit to the rack.
Chapter 6: Advanced Chassis Setup 6-5 Power Supply The SuperServer 6015B-3/6015B-T has a single 560 watt power supply, which is auto-switching capable. This enables it to automatically sense and operate at a 100v to 240v input voltage. An amber light will be illuminated on the power supply when the power is off. An illuminated green light indicates that the power supply is operating. Power Supply Failure If the power supply unit fails, the system will shut down and you will need to replace the unit.
SUPERSERVER 6015B-3/6015B-T User's Manual Figure 6-6.
Chapter 7: BIOS Chapter 7 BIOS 7-1 Introduction This chapter describes the Phoenix BIOS™ Setup utility for the X7DBR-3/X7DBR-E. The Phoenix ROM BIOS is stored in a flash chip and can be easily upgraded using a floppy disk-based program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the Manual Download area of the Supermicro web site
SUPERSERVER 6015B-3/6015B-T User's Manual 7-2 Running Setup Default settings are in bold text unless otherwise noted. The BIOS setup options described in this section are selected by choosing the appropriate text from the main BIOS Setup screen. All displayed text is described in this section, although the screen display is often all you need to understand how to set the options (see next page). When you first power on the computer, the Phoenix BIOS™ is immediately activated.
Chapter 7: BIOS Main BIOS Setup Menu Main Setup Features System Time To set the system date and time, key in the correct information in the appropriate fields. Then press the key to save the data. System Date Using the arrow keys, highlight the month, day and year fields, and enter the correct data. Press the key to save the data. BIOS Date This field displays the date when this version of BIOS was built.
SUPERSERVER 6015B-3/6015B-T User's Manual IDE Channel 0 Master/Slave, IDE Channel 1 Master/Slave, SATA Port2 and SATA Port3 These settings allow the user to set the parameters of IDE Channel 0 Master/ Slave, IDE Channel 1 Master/Slave, IDE Channel 2 Master, IDE Channel 3 Master slots. Hit to activate the following sub-menu screen for detailed options of these items. Set the correct configurations accordingly. The items included in the sub-menu are: Type Selects the type of IDE hard drive.
Chapter 7: BIOS CHS Format The following items will be displayed by the BIOS: TYPE: This item displays the type of IDE or SATA Device. Cylinders: This item indicates the status of Cylinders. Headers: This item indicates the number of headers. Sectors: This item displays the number of sectors. Maximum Capacity: This item displays the maximum storage capacity of the system.
SUPERSERVER 6015B-3/6015B-T User's Manual Parallel ATA This setting allows the user to enable or disable the function of Parallel ATA. The options are Channel 0 and Channel 1. Serial ATA This setting allows the user to enable or disable the function of Serial ATA. The options are Disabled and Enabled. Native Mode Operation Select the native mode for ATA. The options are: Serial ATA, Both, and Auto.
Chapter 7: BIOS System Memory This display informs you how much system memory is recognized as being present in the system. Extended Memory This display informs you how much extended memory is recognized as being present in the system. 7-4 Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. The items with a triangle beside them have sub menus that can be accessed by highlighting the item and pressing .
SUPERSERVER 6015B-3/6015B-T User's Manual Boot Features Access the submenu to make changes to the following settings. QuickBoot Mode If enabled, this feature will speed up the POST (Power On Self Test) routine by skipping certain tests after the computer is turned on. The settings are Enabled and Disabled. If Disabled, the POST routine will run at normal speed. QuietBoot Mode This setting allows you to Enable or Disable the graphic logo screen during boot-up.
Chapter 7: BIOS Memory Cache Cache System BIOS Area This setting allows you to designate a reserve area in the system memory to be used as a System BIOS buffer to allow the BIOS write (cache) its data into this reserved memory area. Select "Write Protect" to enable this function, and this area will be reserved for BIOS ROM access only. Select "Uncached" to disable this function and make this area available for other devices.
SUPERSERVER 6015B-3/6015B-T User's Manual or written into the L1, L2, L3 cache inside the CPU to speed up CPU operations. Select "Uncached" to disable this function. Select "Write Through" to allow data to be cached into the buffer and written into the system memory at the same time. Select "Write Protect" to prevent data from being written into the base memory area of Block 0-512K.
Chapter 7: BIOS Slot#6 PCI-X 133MHz, Slot E1 x8, Slot E2 x4 and Slot E3 x8 Access the submenu for each of the settings above to make changes to the following: Option ROM Scan When enabled, this setting will initialize the device expansion ROM. The options are Enabled and Disabled. Enable Master This setting allows you to enable the selected device as the PCI bus master. The options are Enabled and Disabled. Latency Timer This setting allows you to set the clock rate for Bus Master.
SUPERSERVER 6015B-3/6015B-T User's Manual Memory Branch Mode This option determines how the two memory branches operate. System address space can either be interleaved between the two branches or Sequential from one branch to another. Mirror mode allows data correction by maintaining two copies of data in two branches. Single Channel 0 allows a single DIMM population during system manufacturing. The options are Interleave, Sequential, Mirroring, and Single Channel 0.
Chapter 7: BIOS Advanced Processor Options Access the submenu to make changes to the following settings. CPU Speed This is a display that indicates the speed of the installed processor. Frequency Ratio (Available when supported by the CPU.) The feature allows the user to set the internal frequency multiplier for the CPU. The options are: Default, x12, x13, x14, x15, x16, x17 and x18. Hyperthreading (Available when supported by the CPU.
SUPERSERVER 6015B-3/6015B-T User's Manual Adjacent Cache Line Prefetch (Available when supported by the CPU.) The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The CPU fetches both cache lines for 128 bytes as comprised if Enabled. The options are Disabled and Enabled. Hardware Prefetcher (Available when supported by the CPU.
Chapter 7: BIOS Interrupt This setting allows you to select the IRQ (interrupt request) for serial port A. The options are IRQ3 and IRQ4. Serial Port B This setting allows you to assign control of serial port B. The options are Enabled (user defined), Disabled, Auto (BIOS controlled) and OS Controlled. Mode This setting allows you to set the type of device that will be connected to serial port B. The options are Normal and IR (for an infrared device).
SUPERSERVER 6015B-3/6015B-T User's Manual DMI Event Logging Access the submenu to make changes to the following settings. Event Log Validity This is a display to inform you of the event log validity. It is not a setting. Event Log Capacity This is a display to inform you of the event log capacity. It is not a setting. View DMI Event Log Highlight this item and press to view the contents of the event log. Event Logging This setting allows you to Enable or Disable event logging.
Chapter 7: BIOS Console Redirection Access the submenu to make changes to the following settings. COM Port Address This item allows you to specify to redirect the console to Onboard COM A or Onboard COM B. This setting can also be Disabled. BAUD Rate This item allows you to select the BAUD rate for console redirection. The options are 300, 1200, 2400, 9600, 19.2K, 38.4K, 57.6K, and 115.2K.
SUPERSERVER 6015B-3/6015B-T User's Manual Hardware Monitor Logic Note: The Phoenix BIOS will automatically detect the type of CPU(s) and hardware monitoring chip used on the motherboard and will display the Hardware Monitoring Screen accordingly. Your Hardware Monitoring Screen may look like the one shown on this page, on p. 7-19, or on p. 7-20, depending on the type of CPU(s) and HW Monitoring chip you are using.
Chapter 7: BIOS Hardware Monitor Logic CPU Temperature Threshold (See note on page 7-18.) This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold. The options are 75oC, 80oC, 85oC, and 90oC.
SUPERSERVER 6015B-3/6015B-T User's Manual Hardware Monitor Logic (See note on page 7-18.) CPU Temperature Threshold This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold. The hardcode default setting is 80oC.
Chapter 7: BIOS IPMI (This option available only when an IPMI card is installed in the system.) IPMI Specification Version: This item displays the current IPMI Version. Firmware Version: This item displays the current Firmware Version. System Event Logging Select Enabled to enable IPMI Event Logging. When this function is set to Disabled, the system will continue to log events received via system interface. The options are Enabled and Disabled.
SUPERSERVER 6015B-3/6015B-T User's Manual OS Boot Watch Dog Set to Enabled to enable OS Boot Watch Dog. The options are Enabled and Disabled. Timer for Loading OS (Minutes) This feature allows the user to set the time value (in minutes) for the previous item: OS Boot Watch Dog by keying-in a desired number in the blank. The default setting is 10 (minutes.) (Please ignore this option when OS Boot Watch Dog is set to "Disabled".
Chapter 7: BIOS Realtime Sensor Data This feature display information from motherboard sensors, such as temperatures, fan speeds and voltages of various components.
SUPERSERVER 6015B-3/6015B-T User's Manual 7-5 Security Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. Security setting options are displayed by highlighting the setting using the arrow keys and pressing . All Security BIOS settings are described in this section. Supervisor Password Is: This displays whether a supervisor password has been entered for the system.
Chapter 7: BIOS Password on Boot This setting allows you to require a password to be entered when the system boots up. The options are Enabled (password required) and Disabled (password not required). 7-6 Boot Choose Boot from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. See details on how to change the order and specs of boot devices in the Item Specific Help window. All Boot BIOS settings are described in this section.
SUPERSERVER 6015B-3/6015B-T User's Manual 7-7 Exit Choose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. All Exit BIOS settings are described in this section. Exit Saving Changes Highlight this item and hit to save any changes you made and to exit the BIOS Setup utility. Exit Discarding Changes Highlight this item and hit to exit the BIOS Setup utility without saving any changes you may have made.
Appendix A: BIOS POST Messages Appendix A BIOS POST Messages During the Power-On Self-Test (POST), the BIOS will check for problems. If a problem is found, the BIOS will activate an alarm or display a message. The following is a list of such BIOS messages. Failure Fixed Disk Fixed disk is not working or not configured properly. Check to see if fixed disk is attached properly. Run Setup. Find out if the fixed-disk type is correctly identified. Stuck key Stuck key on keyboard.
SUPERSERVER 6015B-3/6015B-T User's Manual System CMOS checksum bad - Default configuration used System CMOS has been corrupted or modified incorrectly, perhaps by an application program that changes data stored in CMOS. The BIOS installed Default Setup Values. If you do not want these values, enter Setup and enter your own values. If the error persists, check the system battery or contact your dealer. System timer error The timer test failed. Requires repair of system board.
Appendix A: BIOS POST Messages System cache error - Cache disabled RAM cache failed and BIOS disabled the cache. On older boards, check the cache jumpers. You may have to replace the cache. See your dealer. A disabled cache slows system performance considerably. CPU ID: CPU socket number for Multi-Processor error. EISA CMOS not writeable ServerBIOS2 test error: Cannot write to EISA CMOS. DMA Test Failed ServerBIOS2 test error: Cannot write to extended DMA (Direct Memory Access) registers.
SUPERSERVER 6015B-3/6015B-T User's Manual Fixed Disk n Fixed disk n (0-3) identified. Invalid System Configuration Data Problem with NVRAM (CMOS) data. I/O device IRQ conflict I/O device IRQ conflict error. PS/2 Mouse Boot Summary Screen: PS/2 Mouse installed. nnnn kB Extended RAM Passed Where nnnn is the amount of RAM in kilobytes successfully tested. nnnn Cache SRAM Passed Where nnnn is the amount of system cache in kilobytes successfully tested.
Appendix A: BIOS POST Messages Press to resume, to Setup, for previous Displayed after any recoverable error message. Press to start the boot process or to enter Setup and change the settings. Press to display the previous screen (usually an initialization error of an Option ROM, i.e., an add-on card). Write down and follow the information shown on the screen. Press to enter Setup Optional message displayed during POST. Can be turned off in Setup.
SUPERSERVER 6015B-3/6015B-T User's Manual Notes A-6
Appendix B: BIOS POST Codes Appendix B BIOS POST Codes This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are divided into two categories: recoverable and terminal. Recoverable POST Errors When a recoverable type of error occurs during POST, the BIOS will display an POST code that describes the problem.
SUPERSERVER 6015B-3/6015B-T User's Manual POST Code Description 18h 1Ah 1Ch 20h 22h 24h 28h 29h 2Ah 2Ch 2Eh 2Fh 32h 33h 36h 38h 3Ah 3Ch 3Dh 41h 42h 45h 46h 48h 49h 4Ah 4Bh 4Ch 4Eh 4Fh 50h 51h 52h 54h 55h 58h 59h 5Ah 5Bh 8254 timer initialization 8237 DMA controller initialization Reset Programmable Interrupt Controller 1-3-1-1 Test DRAM refresh 1-3-1-3 Test 8742 Keyboard Controller Set ES segment register to 4 GB Auto size DRAM Initialize POST Memory Manager Clear 512 kB base RAM 1-3-4-1 RAM failure on add
Appendix B: BIOS POST Codes POST Code Description 5Ch 60h 62h 64h 66h 67h 68h 69h 6Ah 6Bh 6Ch 70h 72h 76h 7Ch 7Dh 7Eh 80h 81h 82h 83h 84h 85h 86h 87h 88h 89h 8Ah 8Bh 8Ch 8Fh 90h 91h 92h 93h 95h 96h 97h 98h Test RAM between 512 and 640 kB Test extended memory Test extended memory address lines Jump to UserPatch1 Configure advanced cache registers Initialize Multi Processor APIC Enable external and CPU caches Setup System Management Mode (SMM) area Display external L2 cache size Load custom defaults (optiona
SUPERSERVER 6015B-3/6015B-T User's Manual POST Code Description 99h 9Ch 9Dh 9Eh 9Fh A0h A2h A4h A8h AAh ACh AEh B0h B1h B2h B4h B5h B6h B7h B9h BAh BCh BDh BEh BFh C0h C1h C2h C3h C4h C6h C7h C8h C9h CDh Check for SMART Drive (optional) Set up Power Management Initialize security engine (optional) Enable hardware interrupts Determine number of ATA and SCSI drives Set time of day Check key lock Initialize typematic rate Erase prompt Scan for key stroke Enter SETUP Clear Boot flag Check for errors
Appendix B: BIOS POST Codes POST Code Description D2h D4h D8h D9h DEh Unknown interrupt Check Intel Branding string Alert Standard Format initialization Late init for IPMI Log error if micro-code not updated properly The following are for boot block in Flash ROM POST Code E0h E1h E2h E3h E4h E5h E6h E7h E8h E9h EAh EBh ECh EDh EEh EFh F0h F1h F2h F3h F4h F5h F6h F7h Description Initialize the chipset Initialize the bridge Initialize the CPU Initialize system timer Initialize system I/O Check force recov
SUPERSERVER 6015B-3/6015B-T User's Manual Notes B-6
Appendix C: ESB2 HostRAID Setup Appendix C ESB2 HostRAID Setup After all the hardware has been installed, you must first configure Intel's ESB2 SATA RAID before you install the Windows Operating System and other software drivers. Important Notes to the User: If you do not wish to configure onboard SATA RAID functions, please go directly to Section C-3 for Operating System & Other Software Installation.
SUPERSERVER 6015B-3/6015B-T User's Manual The Intel HostRAID Configurations The following types of Intel's HostRAID configurations are supported: RAID 0 (Data Striping): this writes data in parallel, interleaved ("striped") sections of two hard drives. Data transfer rate is doubled over using a single disk. RAID1 (Data Mirroring): an identical data image from one drive is copied to another drive. The second drive must be the same size or larger than the first drive.
Appendix C: ESB2 HostRAID Setup Using the Intel ESB2 SATA RAID Utility Program Creating, Deleting and Resetting RAID Volumes a. After the system exits from the BIOS Setup Utility, the system will automatically reboot. The following screen appears after Power-On Self Test. b. When you see the above screen, press the and the keys simultaneously to have the main menu of the SATA RAID Utility appear: Note: All graphics and screen shots shown in the manual are for reference only.
SUPERSERVER 6015B-3/6015B-T User's Manual Creating a RAID 0 Volume a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 0 set and press the key or the key to go to the next field. (You can use the key to select the previous menu.) c. When RAID Level item is highlighted, press the , keys to select RAID 0 (Stripe) and hit . d.
Appendix C: ESB2 HostRAID Setup Creating a RAID 1 Volume a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 1 set and press the key or the key to go to the next field. (You can use the key to select the previous menu.) c. When RAID Level item is highlighted, press the , keys to select RAID 1 (Mirror) and hit . d.
SUPERSERVER 6015B-3/6015B-T User's Manual Creating a RAID 10 (RAID 1+ RAID 0) a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 10 set and press . c. When RAID Level item is highlighted, use the , keys to select RAID 10 (RAID1 + RAID0) and hit . d.
Appendix C: ESB2 HostRAID Setup Creating a RAID 5 Set (Parity) a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 5 set and press . c. When the Raid Level is highlighted, use the , keys to select RAID 5 (Parity) and hit . d. When the Disk item is highlighted, press to select the HDD to configure as RAID. The following pop-up screen (See Note on Page C-3) displays: e.
SUPERSERVER 6015B-3/6015B-T User's Manual Deleting RAID Volume Warning: Be sure to back up your data before deleting a RAID set. You will lose all data on the disk drives when deleting a RAID set. a. From the main menu, select item2-Delete RAID Volume, and press . b. Use the , keys to select the RAID set you want to delete and press . A Warning message displays. c.
Appendix C: ESB2 HostRAID Setup Resetting to Non-RAID and Resetting a RAID HDD Warning: Be cautious when you reset a RAID volume HDD to nonRAID or Resetting a RAID HDD. Resetting a RAID volume HDD or Resetting a RAID HDD will reformat the HDD and delete the internal RAID structure on the drive. a. From the main menu, select item3-Reset Disks to Non- RAID, and press . The following screen will appear: b.
SUPERSERVER 6015B-3/6015B-T User's Manual C-2 Installing the Windows XP/2000/2003 for systems with RAID Functions New Operating System-Windows XP/2000/2003 Installation a. Insert Microsoft Windows XP/2000/2003 Setup CD in the CD Driver, and the system will start booting up from CD. b. Press the key when the message-" Press F6 if you need to install a third party SCSI or RAID driver" displays. c. When the Windows XP/2000/2003 Setup screen appears, press "S" to specify additional device(s). d.
Appendix D: Adaptec HostRAID Setup Appendix D Adaptec HostRAID Setup (X7DBR-E only) After all the hardware has been installed, you must first configure the Adaptec Embedded Serial ATA RAID before you install the Windows operating system. The necessary drivers are all included on the Supermicro bootable CDs that came packaged with your motherboard. Note: The following section provides information on the Adaptec SATA RAID Driver based on the Intel Enterprise South Bridge 2 (ESB2) Controller.
SUPERSERVER 6015B-3/6015B-T User's Manual Configuring SATA RAID 1. Press the key during system bootup to enter the BIOS Setup Utility. Note: If it is the first time powering on the system, we recommend you load the Optimized Default Settings. If you have already done so, please skip to Step 3. 2. Use the arrow keys to select the "Exit" Settings. Once in the "Exit" settings, Scroll down to select "Load Optimized Default Settings" and press the key. Select "OK" to confirm the selection.
Appendix D: Adaptec HostRAID Setup Adaptec Embedded SATA with HostRAID Controller Driver The Adaptec Embedded Serial ATA RAID Controller adds SATA/RAID functionality and performance enhancements to a motherboard. RAID striping (RAID 0) allows data to be written across multiple drives, greatly improving hard disk I/O performance. RAID mirroring (RAID 1) allows data to be simultaneously written to two drives, improving data security even if a single hard disk fails.
SUPERSERVER 6015B-3/6015B-T User's Manual Managing Arrays Select this option to view array properties, and configure array settings. To select this option, using the arrow keys and the key, select "Managing Arrays" from the main menu as shown above.
Appendix D: Adaptec HostRAID Setup Configuring Disk Drives You may need to configure a disk drive before you can use it. Caution: Configuring a disk may overwrite the partition table on the disk and may make any data on the disk inaccessible. If the drive is used in an array, you may not be able to use the array again. Do not configure a disk that is part of a boot array. To determine which disks are associated with a particular array, please refer to Viewing Array Properties. To configure a disk drive: 1.
SUPERSERVER 6015B-3/6015B-T User's Manual 2. From the "Select Drives for Configuring" List (shown below,) select the drives you want to configure and press . 3. The drive you've selected will appear in the "Selected Drives Dialog Box" on the right (as shown below.) Repeat the same steps until all drives that you want to configure appear in the selected drives box. 4. Once both drives display in the selected drive box, press
Appendix D: Adaptec HostRAID Setup 5. Read the warning message as shown in the screen below. 6. Make sure that you have selected the correct disk drives to configure. If correct, type Y to continue.
SUPERSERVER 6015B-3/6015B-T User's Manual Creating Arrays Before you create arrays, make sure that the disks for the array are connected and installed in your system. Note that disks with no usable space, or disks that are un-initialized or not formatted are shown in gray and cannot be used. (*Note: It is recommended that you configure devices before you create arrays.) To create an array: 1. From the main menu (shown on page D-4), select Create Array. 2.
Appendix D: Adaptec HostRAID Setup Assigning Array Properties Once a new array is completed, you can assign properties to the array. Caution: Once the array is created and its properties are assigned, and you cannot change the array properties using this utility. To assign properties to the new array: 1. In the Array Properties menu (as shown in the screen below), select an array type and press Enter. Only the available array types will be displayed on the screen. (*RAID 0 or RAID 1 requires two drives.
SUPERSERVER 6015B-3/6015B-T User's Manual 5. When you are finished, press (as the screen shown below). Notes: 1. Before adding a new drive to an array, be sure to back up any data stored on the new drive; otherwise, all data will be lost. 2. If you stop the Build or Clear process on a RAID 1, you can restart it by pressing and . 3. If you've used the Quick Init option to create a RAID1, it may return some data mis-comparison when you run a consistency check at a later time. This is normal.
Appendix D: Adaptec HostRAID Setup Adding a Bootable Array To make an array bootable: 1. From the Main menu, select Manage Arrays. 2. From the List of Arrays, select the array you want to make bootable, and press and . 3. Enter Y to create a bootable array when the following message is displayed: "This will make all other existing bootable array non-bootable. Do you want to make this array bootable? (Yes/No):" Then, a bootable array will be created.
SUPERSERVER 6015B-3/6015B-T User's Manual Adding/Deleting Hotspares To add a Hotspare: Note: In order to rebuild a RAID (RAID 0 or RAID 1), you will need to add a new HDD as a hotspare. 1. From the main menu (shown on Page D-4), select Add/Delete Hotspares. 2. Use the up and down arrow keys to highlight and select the disk you want to designate as a hotspare, and press , and then, press . 3.
Appendix D: Adaptec HostRAID Setup Viewing Array Properties To view the properties of an existing array: 1. From the main menu, select Manage Arrays and hit (as shown on the previous page.) 2. From the List of Arrays dialog box (shown below), select the array you want to view and press Enter. The Array Properties dialog box appears (as shown below), showing detailed information on the array. The physical disks associated with the array are displayed here. 3.
SUPERSERVER 6015B-3/6015B-T User's Manual Rebuilding Arrays Note 1: Rebuilding applies to Fault Tolerant array (RAID 1) only. If an array Build process is interrupted or when one critical member is missing, you must perform a Rebuild to restore its functionality. For a critical array rebuild operation, the optimal drive is the source drive. Note 2: If no spare array exists and a hard disk drive fails, you need to create a spare before you can rebuild an array. To Rebuild an array: 1.
Appendix D: Adaptec HostRAID Setup Deleting Arrays Warning: Back up the data on an array before you delete it to prevent data loss Deleted arrays cannot be restored. To delete an existing array: 1. From the main menu (shown on Page D-4), select Manage Arrays. 2. Select the array you wish to delete and press . 3. In the Array Properties dialog box, select Delete and press . The following prompt is displayed: Warning!! Deleting the array will render array unusable.
SUPERSERVER 6015B-3/6015B-T User's Manual Using the Disk Utilities The Disk Utilities enable you to format or verify the media of your Serial ATA hard drives. To access the disk utilities: 1. From the Adaptec RAID Configuration Utility Menu, select Disk Utilities (as shown above) and press . The following screen appears. 2. Select the desired disk and press .
Appendix D: Adaptec HostRAID Setup To format a disk: Note: The operation of Formatting Disk allows you to perform a low-level formatting of a hard drive by writing zeros to the entire disk. Serial ATA drives are low-level formatted at the factory and do not need to be low-level formatted again. 3. When the screen shown below displays, select Format Disk and press . The following screen appears: 4. Read the warning message when it appears in the screen as shown below.
SUPERSERVER 6015B-3/6015B-T User's Manual To verify disk media: 3. When the screen shown above displays, select Verify Disk Media and press . 4. A message will display, indicating that the selected drive will be scanned for media defects. Select Yes and hit to proceed with disk verifying; otherwise, select No and hit .
Appendix D: Adaptec HostRAID Setup To Exit the Adaptec RAID Configuration Utility 1. Once you have completed RAID array configurations, press ESC to exit. The following screen will appear. 2. Press Yes to exit the Utility.
SUPERSERVER 6015B-3/6015B-T User's Manual D-2 Installing Intel's ESB2 Driver by Adaptec and the OS a. Insert Supermicro's bootable CD that came with the package into the CD Drive during the system reboot, and the screen: "Super Micro Driver Diskette Maker" will appear. b. Choose from the list the item: "Intel ESB2 Driver by 3rd Party (Adaptec)" and press . c. From the next screen displayed, choose the OS driver you want to install and press . d.
Appendix E: Software Installation Appendix E Software Installation E-1 Installing Additional Drivers After you've installed the Windows Operating System, a screen as shown below will appear. You are ready to install software programs and drivers that have not yet been installed. To install these software programs and drivers, click the icons to the right of these items. Driver/Tool Installation Display Screen Note: Click the icons showing a hand writing on paper to view the readme files for each item.
SUPERSERVER 6015B-3/6015B-T User's Manual E-2 Configuring Supero Doctor III The Supero Doctor III program is a Web base management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system.
Appendix E: Software Installation Figure E-2. Supero Doctor Screen: Remote Control Note: SD III Software Revision 1.0 can be downloaded from our Web site at: ftp:// ftp.supermicro.com/utility/Supero_Doctor_III/. You can also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend that you use Supero Doctor II.
SUPERSERVER 6015B-3/6015B-T User's Manual Notes E-4
Appendix F: System Specifications Appendix F System Specifications Processors Single or dual Intel® Xeon™ 5100/5000 Sequence processors at a front side (system) bus speed of 1333/1066/667 MHz. Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel 5000P/ESB2 chipset BIOS 8 Mb Phoenix® Flash ROM Memory Capacity Eight 240-pin DIMM sockets supporting up to 32 GB of ECC FBD DDR2-667/533 SDRAM.
SUPERSERVER 6015B-3/6015B-T User's Manual Motherboard 6015B-3: X7DBR-3 (Extended ATX form factor) 6015B-T: X7DBR-E (Extended ATX form factor) Dimensions: 12 x 13.05 in (305 x 331 mm) Chassis SC815S-560 Form Factor: 1U rackmount Dimensions: (WxHxD) 17 x 1.7 x 25.6 in. (432 x 43 x 650 mm) Weight Gross (Bare Bone): 40 lbs. (18.2 kg.
Appendix F: System Specifications Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: EN 60950/IEC 60950-Compliant, UL Listed (USA), CUL Listed (Canada), TUV Certified (Germany), CE Marking (Europe) California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate war
SUPERSERVER 6015B-3/6015B-T User's Manual Notes F-4