1-4
1-2 RAID Levels Supported by the 2108/2208 Controller
The LSI Embedded MegaRAID Software Conguration Utility adds RAID functions
to enhance system efciency and data security by supporting RAID 0, RAID 1, RAID
10, RAID 5, RAID 6, RAID 50 and RAID 60. .
Note: A maximum of 16 physical disk drives is supported for RAID.
RAID 0
RAID 0 (Integrated Striping) can greatly enhance hard disk I/O performance by strip-
ing data across all disk drives in an array or drive group. This RAID conguration
does not provide data redundancy, but it offers the best RAID performance and a
high bandwidth. The following illustration provides a visual example of a RAID 0
drive group.
Segment 1
Segment 3
Segment 5
Segment 7
Segment 2
Segment 4
Segment 6
Segment 8
Drive A
Drive B
RAID 1
RAID 1 (Integrated Mirroring) allows data to be simultaneously written to multiple
drives. This RAID conguration increases data integrity by providing redundancy,
but requires twice the amount of data storage capacity. RAID 1 requires 2 drives.
The following illustration provides a visual example of a RAID 1 drive group.
Segment 1
Segment 1
Duplicate
Segment 3
Duplicate
Segment 3
Drive A
Drive B
RAID 1
Segment 2
Segment 2
Duplicate
Segment 4
Duplicate
Segment 4
Drive C
Drive D
RAID 1
RAID 0 Example