SUPER ® A+ SERVER 1022G-URF USER’S MANUAL Revision1.
A+ Server 1022G-URF User's Guide The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com. Super Micro Computer, Inc.
Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the A+ SERVER 1022G-URF. Installation and maintenance should be performed by experienced technicians only. The A+ SERVER 1022G-URF is a 1U rackmount server based on the SC815TQ-R700UB server chassis and the Super H8DGU-F serverboard. Please refer to our web site for updates on supported processors.
A+ Server 1022G-URF User's Guide Chapter 5: Advanced Serverboard Setup This chapter provides detailed information on the H8DGU-F serverboard, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard. Chapter 6: Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC815TQ-R700UB chassis.
Preface Contents Chapter 1 Introduction 1-1 Overview.......................................................................................................... 1-1 1-2 Serverboard Features...................................................................................... 1-2 Processors....................................................................................................... 1-2 Memory.........................................................................................................
A+ Server 1022G-URF User's Guide 2-5 Installing the System into a Rack.................................................................... 2-4 Identifying the Sections of the Rack Rails....................................................... 2-4 Installing the Outer Rails.................................................................................. 2-5 Installing the Server into the Rack................................................................... 2-6 Installing the Server into a Telco Rack......
Preface Chapter 5 Advanced Serverboard Setup 5-1 Handling the Serverboard................................................................................ 5-1 Precautions...................................................................................................... 5-1 Unpacking........................................................................................................ 5-1 5-2 Processor and Heatsink Installation................................................................
A+ Server 1022G-URF User's Guide 6-3 System Fans.................................................................................................... 6-2 System Fan Failure.......................................................................................... 6-3 6-4 Drive Bay Installation/Removal........................................................................ 6-4 Removing the Front Bezel...............................................................................
Chapter 1: Introduction Chapter 1 Introduction 1-1 Overview The A+ Server 1022G-URF is a high-end server comprised of two main subsystems: the SC815TQ-R700UB 1U server chassis and the H8DGU-F dual processor serverboard. Please refer to our web site for information on operating systems that have been certified for use with the system (www.supermicro.com).
A+ SERVER 1022G-URF User's Manual • Product safety information: http://super-dev/about/policies/safety_information.cfm For support, email support@supermicro.com. 1-2 Serverboard Features At the heart of the A+ SERVER 1022G-URF lies the H8DGU-F, a dual processor serverboard based on the AMD SR5670/SP5100 chipset. Below are the main features of the H8DGU-F. (See Figure 1-1 for a block diagram of the chipset).
Chapter 1: Introduction Note: You must have RAID set up to enable the hot-swap capability of the SATA drives. Documentation on RAID setup guidelines can be found on our web site. Onboard Controllers/Ports The color-coded I/O ports include two COM ports (one header and one port), a VGA (monitor) port, Seven USB 2.0 ports (2x rear, 4x header, 1x type A), PS/2 mouse and keyboard ports, two gigabit Ethernet ports and one dedicated IPMI LAN port.
A+ SERVER 1022G-URF User's Manual PCI Expansion Slots A riser card (RSC-R1UU-UE16, optional) on the right side of the chassis can support an AOC-PG-i2+ add-on card to provide two additional Gb LAN ports. The left side supports a UIO card and one PCI-E x16 card. Front Control Panel The chassis control panel provides you with system monitoring and control. LEDs indicate system power, HDD activity, network activity (two) and UID/overheat/fan fail/power fail.
Chapter 1: Introduction Figure 1-1. AMD SR5670/SP5100 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. DIMM A1 DIMM A0 DIMM B1 DIMM B0 DIMM C1 DIMM C0 DIMM D1 DIMM D0 HT3 Link 16x16-3.2GT/s AMD Socket G34 CPU2 HT3 Link 16x16-3.2GT/s AMD Socket G34 CPU1 HT3 Link (8+8)x(8+8)-3.2GT/s DIMM A1 DIMM A0 DIMM B1 DIMM B0 DIMM C1 DIMM C0 DIMM D1 DIMM D0 HT3 Link 16x16-5.
A+ SERVER 1022G-URF User's Manual 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V.
Chapter 2: Server Installation Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your A+ SERVER 1022G-URF up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc.
A+ SERVER 1022G-URF User's Manual installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). • 2-4 • • • • • • • • • • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display Units. Warnings and Precautions Rack Precautions Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.
Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
A+ SERVER 1022G-URF User's Manual 2-5 Installing the System into a Rack This section provides information on installing the 1022G-URF into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-6 and 2-7. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
Chapter 2: Server Installation Installing the Outer Rails Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail. Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack.
A+ SERVER 1022G-URF User's Manual Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-3 for details.
Chapter 2: Server Installation Installing the Server into a Telco Rack To install the 1022G-URF into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it.
A+ SERVER 1022G-URF User's Manual 2-6 Checking the Serverboard Setup After you install the 1022G-URF in the rack, you will need to open the top cover to make sure the serverboard is properly installed and all the connections have been made. Accessing the Inside of the System 1. First, grasp the two handles on either side and pull the system straight out until it locks. (You will hear a "click.") 2. Depress the two buttons on the top of the chassis to release the top cover (1). 3.
Chapter 2: Server Installation Figure 2-5. Accessing the Inside of the System 2-7 Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the SATA drives and SATA backplane have been properly installed and all connections have been made. Checking the Drives All drives are accessable from the front of the server. The SATA disk drives can be installed and removed from the front of the chassis without removing the top chassis cover.
A+ SERVER 1022G-URF User's Manual Checking the Airflow Airflow is provided by four sets of 4-cm fans (each set of fans consists of two fans that are mounted back to back). The system component layout was carefully designed to direct sufficient cooling airflow to the components that generate the most heat. Note that all power and data cables have been routed in such a way that they do not block the airflow generated by the fans.
Chapter 3: System Interface Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel as well as others on the SAS/SATA drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components. There are also two buttons on the chassis control panel and an on/off switch on the power supply. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
A+ SERVER 1022G-URF User's Manual Power The main power button is used to apply or remove power from the power supply to the server system. Turning off system power with this button removes the main power but keeps standby power supplied to the system. 3-3 Control Panel LEDs The control panel located on the front of the SC815TS-RR700UB chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system.
Chapter 3: System Interface Note: deactivating the UID LED must be performed in the same way it was activated. (If the UID LED was activated via IPMI, you can only turn the LED off via IPMI and not with the UID button.) 2 NIC2 Indicates network activity on LAN2 when flashing. 1 NIC1 Indicates network activity on LAN1 when flashing. HDD On the A+ SERVER 1022G-URF, this light indicates SATA and/or DVD-ROM drive activity when flashing.
A+ SERVER 1022G-URF User's Manual 3-4 Hard Drive Carrier LEDs Each hard drive carrier has two LEDs. • • Green: When illuminated, the green LED on the front of the drive carrier indicates drive activity. A connection to the drive backplane enables this LED to blink on and off when that particular drive is being accessed. Red: The red LED indicates two states. When blinking, it indicates the drive is rebuilding. When solid, it indicates a drive failure.
Chapter 4: Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems 4-1 About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components.
A+ Server 1022G-URF User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
Warning Statements for AC Systems . تحذٌز!هذا الزهز ٌعًٌ خطز اًك فً حالة ٌوكي أى تتسبب فً اصابة جسذٌة كي على علن بالوخاطز الٌاجوة عي الذوائز،قبل أى تعول على أي هعذات الكهزبائٍة وكي على دراٌة بالووارسات الىقائٍة لوٌع وقىع أي حىادث استخذم رقن البٍاى الوٌصىص فً ًهاٌة كل تحذٌز للعثىر تزجوتها 안전을 위한 주의사항 경고! 이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확인하시고 사전에 사고를 방지할 수 있도록 표준 작업절차를 준수해 주시기 바랍니다.
A+ Server 1022G-URF User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A.
A+ Server 1022G-URF User's Manual 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché de toutes les sources de puissance ainsi que de son cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour installer ou enlever des composants de systéme.
A+ Server 1022G-URF User's Manual Equipment Installation Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、交換、 またはサービスを許可 されています。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal gestattet werden.
Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. (This warning does not apply to workstations).
A+ Server 1022G-URF User's Manual אזור עם גישה מוגבלת !אזהרה הגישה ניתנת בעזרת.יש להתקין את היחידה באזורים שיש בהם הגבלת גישה .)' מנעול וכד,כלי אבטחה בלבד (מפתח . تم تخصيص هذه انىحذة نتركُبها فٍ مناطق محظورة ،َمكن انىصىل إنً منطقت محظورة فقط من خالل استخذاو أداة خاصت قفم ومفتاح أو أٌ وسُهت أخري نالمألما 경고! 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다. 특수도구, 잠금 장치 및 키, 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다. Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang.
Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
A+ Server 1022G-URF User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニットは複数の電源装置が接続されている場合があります。 ユニットの電源を切るためには、すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
Chapter 4: Warning Statements for AC Systems .قد يكون لهذا الجهاز عدة اتصاالت بوحدات امداد الطاقة يجب إزالة كافة االتصاالت لعسل الوحدة عن الكهرباء 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을 차단하기 위해서는 모든 연결 단자를 제거해야만 합니다. Waarschuwing Deze eenheid kan meer dan één stroomtoevoeraansluiting bevatten. Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken.
A+ Server 1022G-URF User's Manual מתח בפנל האחורי !אזהרה יש להיזהר במהלך.קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת .העבודה هناك خطز مه التيار الكهزبائي أوالطاقة المىجىدة على اللىحة عندما يكىن النظام يعمل كه حذرا عند خدمة هذا الجهاس 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is. Voorzichtigheid is geboden tijdens het onderhoud.
Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. תיאום חוקי החשמל הארצי !אזהרה .התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים تركيب المعدات الكهربائية يجب أن يمتثل للقىاويه المحلية والىطىية المتعلقة بالكهرباء 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
A+ Server 1022G-URF User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. סילוק המוצר !אזהרה .
Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
A+ Server 1022G-URF User's Manual Power Cable and AC Adapter Warning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only.
Chapter 4: Warning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement.
A+ Server 1022G-URF User's Manual Notes 4-20
Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the H8DGU-F serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter. Remember to close the chassis completely when you have finished working on the serverboard to protect and cool the system sufficiently.
A+ SERVER 1022G-UTF User's Manual 5-2 Processor and Heatsink Installation When handling the processor, avoid placing direct pressure on the label area of the fan. Also, do not place the serverboard on a conductive surface, which can damage the BIOS battery and prevent the system from booting up. Notes: Always connect the power cord last and always remove it before adding, removing or changing any hardware components.
Chapter 5: Advanced Serverboard Setup 3. Use your thumb and your index finger to hold the CPU. Locate and align pin 1 of the CPU socket with pin 1 of the CPU. Both are marked with a triangle. 4. Align pin 1 of the CPU with pin 1 of the socket. Once aligned, carefully place the CPU into the socket. Do not drop the CPU on the socket, move the CPU horizontally or vertically or rub the CPU against the socket or against any pins of the socket, which may damage the CPU and/or the socket. Triangle 5.
A+ SERVER 1022G-UTF User's Manual Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die -- the required amount has already been applied. 2. Place the heatsink directly on top of the CPU so that the heat sink screws are aligned with the mounting holes on the back plate. 3. Make sure the screwdriver torgue setting is no more than 5.0 Kgf-cm (4.3 lbfin) and keep the heat sink direction vertical. 4.
Chapter 5: Advanced Serverboard Setup 5-3 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back.
A+ SERVER 1022G-UTF User's Manual See the Connector Definitions section in this chapter for details and pin descriptions of JF1. Figure 5-1. Front Control Panel Header Pins (JF1) 20 19 Ground NMI x (key) x (key) Power LED Vcc HDD LED Vcc NIC1 (Link) LED NIC1 (Activity) LED NIC2 (Link) LED NIC2 (Activity) LED OH/Fan Fail LED Vcc Power Fail LED Vcc Ground Reset Ground Power 2 5-4 1 I/O Ports The I/O ports are color coded in conformance with the PC 99 specification.
Chapter 5: Advanced Serverboard Setup 5-5 Installing Memory CAUTION! Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Memory Support The H8DGU-F supports up to 512 GB of DDR3-1333/1066/800MHz registered ECC SDRAM or 128 GB of DDR3-1333/1066/800 MHz unbuffered ECC/non-ECC SDRAM in 16 DIMM slots. See the following table for memory installation. Memory speed support is dependent on the type of CPU used on the board. Installing Memory Modules 1.
A+ SERVER 1022G-UTF User's Manual Memory Population for Optimal Performance -For a Motherboard with One CPU (CPU1) Installed # DIMMS CPU 2 DIMMs CPU1 P1-1A Branch 0 4 DIMMs CPU1 P1-1A 8 DIMMs CPU1 P1-1A Branch 1 Branch 2 Branch 3 P1-2A P1-2A P1-1B P1-2A P1-3A P1-2B P1-3A P1-4A P1-3B P1-4A P1-4B Memory Population for Optimal Performance -For a Motherboard with Two CPUs (CPU1 & CPU2) Installed # DIMMS CPU 4 DIMMs CPU1 P1-1A P1-2A CPU2 P2-1A P2-2A CPU1 P1-1A P1-2A P1-3A P1-4A
Chapter 5: Advanced Serverboard Setup Possible System Memory Allocation & Availability System Device Size Physical Memory Available (4 GB Total System Memory) Firmware Hub flash memory (System BIOS) 1 MB 3.99 GB Local APIC 4 KB 3.99 GB Area Reserved for the chipset 2 MB 3.99 GB I/O APIC (4 Kbytes) 4 KB 3.99 GB PCI Enumeration Area 1 256 MB 3.76 GB PCI Express (256 MB) 256 MB 3.51 GB PCI Enumeration Area 2 (if needed) -Aligned on 256-M boundary- 512 MB 3.01 GB VGA Memory 16 MB 2.
A+ SERVER 1022G-UTF User's Manual 5-6 Adding PCI Cards PCI Expansion Slots A riser card is used to support an add-on card to the system and comes preinstalled. Installing a PCI Expansion Card 1. Remove the chassis cover. 2. Install the riser card by sliding card into the appropriate slot in the motherboard. 3. Choose the PCI slot shield in which to place the add-on card. 4. In that slot, open the PCI slot shield lever and slide the shield sideways. 5. From inside the chassis, remove the PCI slot shield.
Chapter 5: Advanced Serverboard Setup 5-7 Serverboard Details Figure 5-4. SUPER H8DGU-F Layout (not drawn to scale) UID FAN8 JPL1 KB/MOUSE LAN1 LAN2 UIOP USB0/1 IPMI_LAN COM1 VGA LE1 P2-DIMM1A P2-DIMM1B P2-DIMM2B P2-DIMM2A P2-DIMM3B P2-DIMM3A P2-DIMM4B P2-DIMM4A CPU2 PCI-E 2.0 x16 SLOT JI2C1 JI2C2 COM2 JPG1 JWD BATTERY JP2 P1-DIMM4B P1-DIMM3B P1-DIMM4A P1-DIMM2B P1-DIMM3A P1-DIMM1B P1-DIMM2A T-SGPIO2 T-SGPIO1 DP2 P1-DIMM1A PCI-E 2.
A+ SERVER 1022G-UTF User's Manual H8DGU(-F) Quick Reference Jumper Description Default Setting JBT1 CMOS Clear (See Section 5-9) JI2C1/JI2C2 I2C to PCI-E Slot Enable/Disable Both Closed (Enabled) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPL1 LAN 1/2 Enable/Disable Pins 1-2 (Enabled) JWD Watch Dog Pins 1-2 (Reset) LED Description LAN Ports LEDs for the LAN Ethernet ports Dedicated IPMI LAN LEDs for the dedicated IPMI LAN Ethernet port LE1 LED for UID Button DP2 LED for Serverboa
Chapter 5: Advanced Serverboard Setup 5-8 Connector Definitions ATX Power 24-pin Connector Pin Definitions Power Connectors A 24-pin main power supply connector(JPW1) and three 8-pin CPU PWR connectors (JPW2/JPW3/JPW4) on the motherboard. These power connectors meet the SSI EPS 12V specification. In addition to the 24-pin ATX power connector, the 12V 8-pin CPU PWR connectors at JPW2/JPW3/JPW4 must also be connected to your power supply. See the table on the right for pin definitions.
A+ SERVER 1022G-UTF User's Manual Overheat/Fan Fail LED (OH) Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide advanced warning of chassis overheating or fan failure. Refer to the table on the right for pin definitions and status indicators. NIC2 (LAN2) LED The LED connections for LAN2 are on pins 9 and 10 of JF1. Attach LAN LED cables to display network activity. See the table on the right for pin definitions. NIC1 (LAN1) LED The LED connections for LAN1 are on pins 11 and 12 of JF1.
Chapter 5: Advanced Serverboard Setup Universal Serial Bus Ports Two Universal Serial Bus ports (USB 2.0) are located beside the Keyboard and Mouse PS2 ports. One additional Type A port (USB6) is included on the motherboard. See the table on the right for pin definitions. Universal Serial Bus Ports Pin Definitions (USB0/1, USB6) USB0 Pin # Definition USB1 Pin # Definition 1 +5V 1 +5V 2 PO- 2 PO- 3 PO+ 3 PO+ 4 Ground 4 Ground USB Headers Four USB 2.
A+ SERVER 1022G-UTF User's Manual T-SGPIO The T-SGPIO1/ T-SGPIO2 (Serial General Purpose Input/Output) headers provide a bus between the SATA controller and the backpane to provide SATA enclosure management functions. Connect the appropriate cable from the backplane to the T-SGPIO1 header to utilize SATA management functions on your system.
Chapter 5: Advanced Serverboard Setup Chassis Intrusion Chassis Intrusion Pin Definitions (JL1) A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform you of a chassis intrusion. Pin# Definition 1 Battery voltage 2 Intrusion signal Overheat LED Overheat LED Pin Definitions (JOH1) Connect an LED to the JOH1 header to provide warning of chassis overheating. See the table on the right for pin definitions. Pin# Definition Power LED/Speaker 3.
A+ SERVER 1022G-UTF User's Manual Unit Identifier Button In addition to the UID (Unit Identifier) button on the rear I/O panel, there is another UID button located on the control panel. When you push either UID button, both Rear UID and Front Panel UID Indicators will illuminate. Push either button again to turn off both indicators. These UID indicators provide easy identification of a system unit that may be in need of service.
Chapter 5: Advanced Serverboard Setup 5-9 Jumper Settings Connector Pins 3 2 1 3 2 1 Explanation of Jumpers To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit board. See the diagram at right for an example of jumping pins 1 and 2. Refer to the motherboard layout page for jumper locations.
A+ SERVER 1022G-UTF User's Manual I2C to PCI-Express Slot JI2C1/JI2C2 allows you to enable the I2C bus to communicate with the PCI-Express slot. For the jumpers to work properly, please set both jumpers to the same setting. If enabled, both jumpers must be enabled. If disabled, both jumpers must be disabled. See the table on the right for jumper settings. Watch Dog Enable/Disable JWD enables the Watch Dog function, a system monitor that takes action when a software application freezes the system.
Chapter 5: Advanced Serverboard Setup 5-10 Onboard Indicators LAN LED (Connection Speed Indicator) LAN1/LAN2 LEDs The Ethernet ports (located beside the VGA port) have two LEDs. On each Gb LAN port, one LED blinks to indicate activity while the other may be green, amber or off to indicate the speed of the connection. See the table on the right for the functions associated with the connection speed LED. Dedicated IPMI LAN LEDs A dedicated IPMI LAN is also included on the H8DGU-F serverboard (DP5001).
A+ SERVER 1022G-UTF User's Manual 5-11 SATA Drive Connections SATA Ports There are no jumpers to configure the SATA ports, which are designated SATA0 through SATA5. See the table on the right for pin definitions.
Chapter 5: Advanced Serverboard Setup 5-12 Enabling SATA RAID Now that the hardware is set up, you must install the operating system and the SATA RAID drivers, if you wish to use RAID with your SATA drives. The installation procedure differs depending on whether you wish to have the operating system installed on a RAID array or on a separate non-RAID drive. See the instructions below for details.
A+ SERVER 1022G-UTF User's Manual Enabling SATA RAID in the BIOS Before installing the Windows operating system, you must change some settings in the BIOS. Boot up the system and hit the key to enter the BIOS Setup Utlility. After the setup utility loads, 1. Use the arrow keys to move to the "Exit" menu. Scroll down using the arrow keys to "Load Optimal Defaults" and press . Select "OK" to confirm, then to load the default settings. 2.
Chapter 5: Advanced Serverboard Setup Figure 5-6. DotHill RAID Utility Program Screen Figure 5-7. Adaptec RAID Utility Program Screen Using the DotHill and Adaptec RAID Utility The RAID Utility program allows you to define the drives you want to include in the RAID array and the mode and type of RAID.
A+ SERVER 1022G-UTF User's Manual Installing the RAID Driver During OS Installation You may also use the procedure below to install the RAID driver during the Windows OS installation: 1. With the Windows OS installation CD-ROM in the CD drive, restart the system. 2. Press again to continue with the Windows setup. 3. When you see the prompt, hit the key to enter Windows setup. 4.
Chapter 5: Advanced Serverboard Setup Figure 5-8. Driver/Tool Installation Display Screen Note: Click the icons showing a hand writing on paper to view the readme files for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After installing each item, you must reboot the system before moving on to the next item on the list. The bottom icon with a CD on it allows you to view the entire contents.
A+ SERVER 1022G-UTF User's Manual Figure 5-9. SuperDoctor III Interface Display Screen (Health Information) Figure 5-10. SuperDoctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/software/ SuperDoctorIII.cfm.For Linux, we recommend that you use the SuperoDoctor II application instead.
Chapter 5: Advanced Serverboard Setup 5-14 Serverboard Battery Caution: There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 5-11). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032). Dispose of used batteries according to the manufacturer's instructions. Figure 5-11. Installing the Onboard Battery Please handle used batteries carefully.
A+ SERVER 1022G-UTF User's Manual Notes 5-30
Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the 815TS-R700UBP chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step. Tools Required: The only tool you will need to install components and perform maintenance is a Philips screwdriver.
A+ SERVER 1022G-URF User's Manual Figure 6-1. Chassis: Front and Rear Views Slim DVD-ROM Drive System LEDs Hard Drive Bays Control Panel System Reset Main Power Power Supply Modules USB Ports PCI Expansion Slots (w/ Riser Cards) Mouse/Keyboard Ports COM1 Port VGA Port Ethernet Ports Note: the SC815TQ-560UBP chassis (6016T-UF/6016T-NTF) has only a single power supply module.
Chapter 6: Advanced Chassis Setup Figure 6-2. System Cooling Fans Optional Fan System Fan Failure Fan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining fan will ramp up to full speed and the overheat/fan fail LED on the control panel will turn on. Replace any failed fan at your earliest convenience with the same type and model (the system can continue to run with a failed fan).
A+ SERVER 1022G-URF User's Manual 5. Reposition the fan housing back over the two mounting posts in the chassis, then reconnect the fan wires to the same chassis fan headers you removed them from. 6. Power up the system and check that the fan is working properly and that the LED on the control panel has turned off. Finish by replacing the chassis cover.
Chapter 6: Advanced Chassis Setup Hard Drive Installation The hard drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airflow for the drive bays. For this reason, even empty carriers without drives installed must remain in the chassis. Mounting a Hard Drive in a Drive Carrier 1. Insert a drive into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier. 2.
A+ SERVER 1022G-URF User's Manual Installing/Removing a Hard Drive 1. To remove a carrier, push the release button located beside the drive LEDs. 2. Swing the colored handle fully out and use it to pull the unit straight out (see Figure 6-5). Note: Your operating system must have RAID support to enable the hot-plug capability of the hard drives. Figure 6-5.
Chapter 6: Advanced Chassis Setup 2. Depress the two buttons on the top of the chassis to release the top cover and at the same time, push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server. Removing/Installing a Drive 1. With the chassis cover removed, unplug the power and data cables from the drive you want to remove. 2. Locate the locking tab at the rear of the drive.
A+ SERVER 1022G-URF User's Manual Replacing the Power Supply You do not need to shut down the system to replace a power supply module. The redundant feature will keep the system up and running while you replace the failed hot-swap module. Replace with the same model, which can be ordered directly from Supermicro (see Contact Information in the Preface). 1. First unplug the power cord from the failed power supply module. 2.
Chapter 7: BIOS Chapter 7 BIOS 7-1 Introduction This chapter describes the AMI BIOS Setup Utility for the A+ SERVER 1022G-URF. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens. Starting the Setup Utility To enter the BIOS Setup Utility, hit the key while the system is booting-up. (In most cases, the key is used to invoke the BIOS setup screen.
A+ Server 1022G-URF User's Manual System Time/System Date You can edit this field to change the system time and date. Highlight System Time or System Date using the keys. Enter new values through the keyboard. Press the key or the keys to move between fields. The date must be entered in DAY/MM/DD/YYYY format. The time is entered in HH:MM:SS format. Please note that time is in a 24-hour format. For example, 5:30 A.M. appears as 05:30:00 and 5:30 P.M. as 17:30:00.
Chapter 7: BIOS Watch Dog Function Allows system to restart when system is inactive more than 5-minutes. The options are Enabled and Disabled. Power Button Function This sets the function of the power button when you turn off the system. Options include 4-second Overide and Instant Off. Restore on AC Power Loss This sets the action that occurs when an AC power loss occurs. Options include Power Off, Power On and Last State. Interrupt 19 Capture Select Enabled to allow ROMs to trap Interrupt 19.
A+ Server 1022G-URF User's Manual Power Cap This option can decide the highest P-state in the OS. Options include P-state 0 through P-state 4. ACPI SRAT Table This option Enables or Disables the building of the ACPI SRAT Table. CPU Down Core This option sets down core support for the CPU. Options include Disabled, 2 Cores through 10 Cores in even numbered increments. C1E Support This option enables C1E support. Options include Enabled and Disabled.
Chapter 7: BIOS Bank Swizzle Mode This setting Enables or Disables the bank swizzle mode. ECC Configuration ECC Mode This submenu affects the DRAM scrub rate based on its setting. Options include Disabled, Basic, Good, Super, Max and User. Selecting User activates the other options for user setting. DRAM ECC Enable This setting allows hardware to report and correct memory errors automatically, maintaining system integrity. Options are Enabled or Disabled.
A+ Server 1022G-URF User's Manual Legacy USB Support Select "Enabled" to enable the support for USB Legacy. Disable Legacy support if there are no USB devices installed in the system. "Auto" disabled Legacy support if no USB devices are connected. The options are Disabled, Enabled and Auto. IDE Configuration Onboard PCI IDE Controller This setting allows you to Enable or Disable the PCI IDE controller. OnChip SATA Channel This setting allows you to Enable or Disable the OnChip SATA channel.
Chapter 7: BIOS Select "Disabled" to allow the data to be transferred from and to the device one sector at a time. Select "Auto" to allows the data transfer from and to the device occur multiple sectors at a time if the device supports it. The options are Auto and Disabled. PIO Mode PIO (Programmable I/O) mode programs timing cycles between the IDE drive and the programmable IDE controller. As the PIO mode increases, the cycle time decreases. The options are Auto, 0, 1, 2, 3, and 4.
A+ Server 1022G-URF User's Manual PCI/PnP Configuration Clear NVRAM Select Yes to clear NVRAM during boot-up. The options are Yes and No. Plug & Play O/S Select Yes to allow the OS to configure Plug & Play devices. (This is not required for system boot if your system has an OS that supports Plug & Play.) Select No to allow AMIBIOS to configure all devices in the system. PCI Latency Timer This option sets the latency of all PCI devices on the PCI bus.
Chapter 7: BIOS I/O port address and IRQ 4 for the interrupt address. Options include Disabled, 3F8/IRQ4, 3E8/IRQ4 and 2E8/IRQ3 Serial 2 Address This option specifies the base I/O port address and Interrupt Request address of serial port 2. Select "Disabled" to prevent the serial port from accessing any system resources. When this option is set to "Disabled", the serial port physically becomes unavailable.
A+ Server 1022G-URF User's Manual Terminal Type Selects the type of the target terminal. Options are ANSI, VT100 and VT-UTF8. VT-UTF8 Combo Key Support Allows you to Enable or Disable VT-UTF8 combination key support for ANSI/ VT100 terminals. Sredir Memory Display Delay Use this setting to set the delay in seconds to display memory information. Options are No Delay, 1 sec, 2 secs and 4 secs.
Chapter 7: BIOS ACPI APIC Support Determines whether to include the ACPI APIC table pointer in the RSDT pointer list. The available options are Enabled and Disabled. Headless Mode Use this setting to Enable or Disable headless operation mode through ACPI. ACPI Version Features Use this setting the determine which ACPI version to use. Options are ACPI v1.0, ACPI v2.0 and ACPI v3.0.
A+ Server 1022G-URF User's Manual IP Address This submenu sets the IP address source as either Static or DHCP. Selecting Static allows you to manually set the IP Address, Subnet Mask and Gateway Address. In the field provided here enter the IP address in the decimal form of xxx.xxx. xxx.xxx with xxx having a value of less than 256 and in decimal form only The IP address and current IP address in the BMC are shown. Subnet Mask In the field provided here enter the Subnet address in the decimal form of xxx.
Chapter 7: BIOS SR56x0 (RD890S) PCIE Error Log This setting allows you set an error log ofr PCIE errors. Options include Yes or No. 7-4 Security Menu AMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set first. Change Supervisor Password Select this option and press to access the sub menu, and then type in the password. Change User Password Select this option and press to access the sub menu, and then type in the password.
A+ Server 1022G-URF User's Manual This feature allows you to specify the boot sequence from the list of available CD/ DVD drives. A device that is in parenthesis has been disabled in the corresponding type menu. Retry Boot Devices This option allows you to retry boot devices. Options include Enabled and Disabled. 7-6 Exit Menu Select the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.
Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen. Fatal errors are those which will not allow the system to continue the boot-up procedure.
A+ SERVER 1022G-URF User's Manual Notes A-2
Appendix B: Installing Windows Appendix B Installing Windows After all hardware components have been installed, you must first configure Intel South Bridge RAID Settings before you install the Windows OS and other software drivers. To configure RAID settings, please refer to RAID Configuration User Guides posted on our web site at www.supermicro.com/support/manuals. Note: The following OS installation instructions are written for the Windows XP/2003 OS only.
A+ SERVER 1022G-URF User's Manual 9. From the Windows XP/Windows 2003 Setup screen, press the key. The XP/2003 Setup will automatically load all device files and then, continue the Windows XP/Windows 2003 installation. 10. After the Windows XP/Windows 2003 OS Installation has completed, the system will automatically reboot. B-2 Installing the Windows OS for a Non-RAID System 11.
Appendix C: System Specifications Appendix C System Specifications Processors Dual AMD Opteron 6000 series (AMD Socket G34 type) processors Note: You must install at least two processors for full functions to be supported. Note: Please refer to our web site for a complete listing of supported processors.
A+ SERVER 1022G-URF User's Manual Expansion Slots One UIO card and one PCI Express x16 slot Serverboard H8DGU-F (Proprietary form factor) Dimensions: 12.28" x 13.05" (312 x 331 mm) Chassis SC815TQ-R700UBP Form Factor: 1U rackmount Dimensions: (WxHxD) 17 x 1.7 x 25.6 in. (432 x 43 x 650 mm) Weight Gross (Bare Bone): 43 lbs. (19.5 kg.
Appendix C: System Specifications Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to prod
A+ SERVER 1022G-URF User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.