SUPER ® SUPERSERVER 6015B-Ni USER’S MANUAL 1.
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com.
Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6015B-Ni. Installation and maintenance should be performed by experienced technicians only.
SUPERSERVER 6015B-Ni Manual Chapter 4: System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6015B-Ni. Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X7DBU serverboard, including the locations and functions of connectors, headers and jumpers.
Preface Notes v
SUPERSERVER 6015B-Ni Manual Table of Contents Preface About This Manual ...................................................................................................... iii Manual Organization ................................................................................................... iii Chapter 1: Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features ................................
Table of Contents HDD .......................................................................................................... 3-3 Power ....................................................................................................... 3-3 Chapter 4: System Safety 4-1 Electrical Safety Precautions .......................................................................... 4-1 4-2 General Safety Precautions ...........................................................................
SUPERSERVER 6015B-Ni Manual Power LED/Speaker ............................................................................... 5-16 ATX PS/2 Keyboard & Mouse Ports ...................................................... 5-16 Overheat LED ........................................................................................ 5-16 Wake-On-LAN ........................................................................................ 5-17 Wake-On-Ring ...............................................................
Table of Contents Chapter 7: BIOS 7-1 Introduction ..................................................................................................... 7-1 7-2 Running Setup ................................................................................................ 7-2 7-3 Main BIOS Setup ............................................................................................ 7-2 7-4 Advanced Setup ............................................................................................
SUPERSERVER 6015B-Ni User's Manual Notes x
Chapter 1: Introduction Chapter 1 Introduction 1-1 Overview Supermicro's SuperServer 6015B-Ni is an economic, dual processor 1U rackmount server. The SuperServer 6015B-Ni is comprised of two main subsystems: the SC812L-520U 1U rackmount chassis and the X7DBU dual processor serverboard. Please refer to our web site for information on operating systems that have been certified for use with the SuperServer 6015B-Ni. (www.supermicro.
SUPERSERVER 6015B-Ni Manual 1-2 Serverboard Features At the heart of the SuperServer 6015B-Ni lies the X7DBU, a dual processor serverboard based on Intel's 5000P chipset. Below are the main features of the X7DBU (see Figure 1-1 for a block diagram of the chipset). Processors The X7DBU supports single or dual 771-pin Intel Xeon 5300/5100/5000 series processors at a FSB speed of 1333/1066/667 MHz.
Chapter 1: Introduction ATI Graphics Controller The X7DBU features an integrated ATI video controller based on the ES1000 graphics chip. The ES1000 was designed specifically for servers, featuring low power consumption, high reliability and superior longevity. Other Features Other onboard features that promote system health include onboard voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue. Figure 1-1.
SUPERSERVER 6015B-Ni Manual 1-3 Server Chassis Features The SC812L-520U is Supermicro's second-generation 1U chassis and features three hard drive bays, two front side USB ports and a revolutionary cooling design that can keep today's most powerful processors running well below their temperature thresholds. The following is a general outline of the main features of the SC812L520U chassis. System Power When configured as a SuperServer 6015B-Ni, the SC812L-520U chassis includes a 520W power supply.
Chapter 1: Introduction 1-4 Contacting Super Micro Headquarters Address: Tel: Fax: Email: Web Site: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. +1 (408) 503-8000 +1 (408) 503-8008 marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) www.supermicro.com Europe Address: Tel: Fax: Email: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands +31 (0) 73-6400390 +31 (0) 73-6416525 sales@supermicro.
SUPERSERVER 6015B-Ni Manual Notes 1-6
Chapter 2: Server Installation Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your SuperServer 6015B-Ni up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your SuperServer 6015B-Ni system has come to you with the processors and memory preinstalled.
SUPERSERVER 6015B-Ni Manual Choosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). - Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing. - This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
SUPERSERVER 6015B-Ni Manual 2-4 Installing the System into a Rack This section provides information on installing the SuperServer 6015B-Ni into a rack. If the 6015B-Ni has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the 6015B-Ni into a rack with the rack rails provided.
Chapter 2: Server Installation Installing the Chassis Rails Position the fixed chassis rail sections you just removed along the side of the 6015B-Ni making sure the screw holes line up. Note that these two rails are left/right specific. Screw the rail securely to the side of the chassis (see Figure 2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installng into a telco rack.
SUPERSERVER 6015B-Ni Manual Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-3.
Chapter 2: Server Installation Installing the Server into a Telco Rack To install the SuperServer 6015B-Ni into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it.
SUPERSERVER 6015B-Ni Manual 2-5 Checking the Serverboard Setup After you install the 6015B-Ni in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made. 1. Accessing the inside of the 6015B-Ni (see Figure 2-5) First, release the retention screws that secure the unit to the rack. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click").
Chapter 2: Server Installation 2-6 Checking the Drive Bay Setup Next, you should check to make sure the hard drives have been properly installed and all connections have been made. 1. Accessing the drive bays For servicing the hard drives, you will need to remove the top chassis cover. If you need to remove or install hard drives, please refer to Chapter 6. 2. Check the airflow Airflow is provided by two heavy-duty 10-cm blower fans.
SUPERSERVER 6015B-Ni Manual Notes 2-10
Chapter 3: System Interface Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel to keep you constantly informed of the overall status of the system. There are also three buttons on the chassis control panel. 3-2 Control Panel Buttons There are three buttons located on the front of the chassis: a reset button, a power on/off button and a UID button. RESET: Use the reset button to reboot the system.
SUPERSERVER 6015B-Ni Manual 3-3 Control Panel LEDs The control panel located on the front of the SC812L-520U chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take. Universal Information LED: When this LED blinks red slowly, it indicates a fan failure and when blinking red quickly a power failure.
Chapter 3: System Interface NIC2: Indicates network activity on LAN2 when flashing. NIC1: Indicates network activity on LAN1 when flashing. HDD: Indicates IDE channel activity when flashing. Power: Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating.
SUPERSERVER 6015B-Ni Manual Notes 3-4
Chapter 4: System Safety Chapter 4 System Safety 4-1 Electrical Safety Precautions ! Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 6015B-Ni from damage: Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system.
SUPERSERVER 6015B-Ni User's Manual Serverboard Battery: CAUTION - There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarities (see Figure 4-1). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. DVD-ROM Laser: CAUTION - this server may have come equipped with a DVD-ROM drive.
Chapter 4: System Safety After accessing the inside of the system, close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made. 4-3 ESD Precautions ! Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic components and printed circuit boards.
SUPERSERVER 6015B-Ni User's Manual 4-4 Operating Precautions ! Care must be taken to assure that the chassis cover is in place when the 6015B-Ni is operating to ensure proper cooling. Out of warranty damage to the 6015B-Ni system can occur if this practice is not strictly followed. Figure 4-1.
Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X7DBU serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter. Remember to close the chassis completely when you have finished working on the serverboard to protect and cool the system sufficiently.
SUPERSERVER 6015B-Ni User's Manual 5-2 Processor and Heatsink Installation When handling the processor, avoid placing direct pressure on the label ! area of the fan. Also, do not place the serverboard on a conductive surface, which can damage the BIOS battery and prevent the system from booting up. IMPORTANT! Always connect the power cord last and remove it first before adding, removing or changing any hardware components.
Chapter 5: Advanced Serverboard Setup 3. Use your thumb and your index finger to hold the CPU at opposite sides. 4. Align pin1 of the CPU (the corner marked with a triangle) with the notched corner of the CPU socket. 5. Find the corner of the CPU that Gold dot has a semi-circle cutout below a gold Socket key dot (CPU key). This corner should be aligned with the cutout on the socket (socket key). CPU key 6. Once aligned, carefully lower the CPU straight down into the socket.
SUPERSERVER 6015B-Ni User's Manual Installing the Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the (preinstalled) heatsink retention mechanism. 3. Screw in two diagonal screws (i.e. the #1 and the #2 screws) until just snug. Do not fully tighten the screws or you may damage the CPU.) 4.
Chapter 5: Advanced Serverboard Setup 5-3 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The ribbon cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back.
SUPERSERVER 6015B-Ni User's Manual Connecting the Control Panel JF1 contains header pins for various front control panel connectors. See Figure 5-1 for the pin locations of the various front control panel buttons and LED indicators. Please note that even and odd numbered pins are on opposite sides of each header. All JF1 wires have been bundled into single keyed ribbon cable to simplify their connection. The red wire in the ribbon cable plugs into pin 1 of JF1.
Chapter 5: Advanced Serverboard Setup 5-4 I/O Ports The I/O ports are color coded in conformance with the PC 99 specification. See Figure 5-2 below for the colors and locations of the various I/O ports. Figure 5-2. Rear Panel I/O Ports Mouse (Green) USB0/1 Ports COM1 Port (Turquoise) VGA Port (Blue) LAN1 LAN2 UID Keyboard (Purple) 5-5 Installing Memory Note: Check the Supermicro web site for recommended memory modules.
SUPERSERVER 6015B-Ni User's Manual modules of the same size and speed to be installed in pairs. You should not mix DIMMs of different sizes and speeds. Notes: Due to OS limitations, some operating systems may not show more than 4 GB of memory. Due to memory allocation to system devices, memory remaining available for operational use will be reduced when 4 GB of RAM is used. The reduction in memory availability is disproportional. (Refer to the Memory Availability Table below for details.
Chapter 5: Advanced Serverboard Setup 5-6 Adding PCI Cards 1. PCI Expansion Slots Two riser cards are used to support add-on cards to the system. The SC812L-520U chassis can accommodate two standard size (full height full length) and one low profile PCI expansion card. When viewed from the chassis front, the standard size card installs to the left and the low-profile card installs to the right side. PCI cards are installed into riser cards that have been pre-installed to the system.
SUPERSERVER 6015B-Ni User's Manual 5-7 Serverboard Details Figure 5-4.
Chapter 5: Advanced Serverboard Setup X7DBU Quick Reference Jumper Description Default Setting JBT1 II2C1/II2C2 CMOS Clear I2C Enable/Disable (See Section 5-9) Open (Disabled) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPL1/ JPL2 JWD JLAN1/JLAN2 Enable/Disable Watch Dog Pins 1-2 (Enabled) Pins 1-2 (Reset) Connector Description COM1/COM2 FAN 1-8 Floppy IDE#1 JD1 JF1 JL1 JK1 JOH1 JPW1 JPW2 JPW3 JWOL JWOR LAN1/2 SATA0~SATA5 SGPIO1/SGPIO2 SIMSO SMB SMBUS_PS COM1/COM2 Serial Port Connector/Header
SUPERSERVER 6015B-Ni User's Manual 5-8 Connector Definitions ATX Power 20-pin Connector Pin Definitions (JPW1) ATX Power Connector The primary ATX power supply connector meets the SSI (Superset ATX) 20-pin specification. Make sure that the orientation of the connector is correct. See the table on the right for pin definitions. Pin# Definition Pin # Definition 11 +3.3V 1 +3.3V 12 -12V 2 +3.
Chapter 5: Advanced Serverboard Setup HDD LED HDD LED Pin Definitions (JF1) The HDD (IDE Hard Disk Drive) LED Pin# Definition connection is located on pins 13 and 13 Vcc 14 of JF1. Attach the IDE hard drive LED cable to display disk activity. 14 HD Active Refer to the table on the right for pin definitions. NIC1 LED NIC1 LED Pin Definitions (JF1) The NIC1 (Network Interface Controller) LED connection is located on pins 11 and 12 of JF1. Attach the NIC1 LED cable to display network activity.
SUPERSERVER 6015B-Ni User's Manual Power Fail LED Power Fail LED Pin Definitions (JF1) The Power Fail LED connection is Pin# Definition located on pins 5 and 6 of JF1. Re- 5 Vcc fer to the table on the right for pin definitions. 6 Ground Reset Button Reset Button Pin Definitions (JF1) The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to the hardware reset switch on the computer case. Refer to the table on the right for pin definitions.
Chapter 5: Advanced Serverboard Setup Universal Serial Bus Headers Universal Serial Bus Headers Pin Definitions (USB2, USB3, USB4) Three additional USB headers (USB2/ USB3 and USB4) are included on the serverboard. These may be used for front side access. A USB cable (not included) is needed for the connection. See the table on the right for USB2 Pin # Definition USB3, USB4 Pin # Definition 1 +5V 1 +5V 2 PO- 2 PO- 3 PO+ 3 PO+ 4 Ground 4 Ground 5 Key 5 NC pin definitions.
SUPERSERVER 6015B-Ni User's Manual Chassis Intrusion Chassis Intrusion Pin Definitions (JL1) A Chassis Intrusion header is located Pin# Definition at JL1. Attach the appropriate cable 1 Intrusion Input to inform you of a chassis intrusion. 2 Ground Power LED/Speaker Speaker Connector Pin Definitions (JD1) On the JD1 header, pins 1-3 are for a power LED, pins 4-7 are for the speaker. See the table on the right for speaker pin definitions.
Chapter 5: Advanced Serverboard Setup Wake-On-LAN Wake-On-LAN Pin Definitions (JWOL) The Wake-On-LAN header is designated JWOL. See the table on the right for pin definitions. You must enable the LAN Wake-Up setting in BIOS to use this feature. You must Pin# Definition 1 +5V Standby 2 Ground 3 Wake-up also have a LAN card with a Wakeon-LAN connector and cable. Wake-On-Ring Wake-On-Ring Pin Definitions (JWOR) The Wake-On-Ring header is designated JWOR.
SUPERSERVER 6015B-Ni User's Manual JLAN1/2 (Ethernet Ports) Two Ethernet ports (designated JLAN1 and JLAN2) are located beside the VGA port on the I/O backplane. These ports accept RJ45 type cables. Alarm Reset (JAR) The system will notify you in the event of a power supply failure. This feature assumes that Supermicro redundant power supply units are installed in the chassis. Connect a microswitch to the JAR header to disable the power supply fail alarm.
Chapter 5: Advanced Serverboard Setup 5-9 Jumper Settings Explanation of Jumpers To m o di f y t he operat i on of t he serverboard, jumpers can be used 3 2 1 3 2 1 Connector Pins to choose between optional settings. Jumpers create shorts between two Jumper pins to change the function of the connector. Pin 1 is identified with a square solder pad on the printed circuit Setting board. See the diagram at right for an example of jumping pins 1 and 2.
SUPERSERVER 6015B-Ni User's Manual LAN Enable/Disable LAN Enable/Disable Jumper Settings (JPL1, JPL2) Change the setting of jumper JPL1 Jumper Setting or JPL2 to enable or disable the Pins 1-2 Enabled onboard Ethernet (RJ45) ports LAN1 and LAN2, respectively. See the table Pins 2-3 Disabled Definition on the right for jumper settings. The default setting is enabled Watch Dog Enable/Disable JWD controls the Watch Dog function.
Chapter 5: Advanced Serverboard Setup 5-10 Onboard Indicators LAN LED Connection Speed Indicator LAN1/LAN2 LEDs LED Color Definition The Ethernet ports (located beside the Off 10 MHz VGA port) have two LEDs. On each Green 100 MHz Gigabit LAN port, one LED indicates activity when blinking while the other Amber 1 GHz LED may be green, amber or off to indicate the speed of the connection. See the table on the right for the functions associated with the connection speed LED.
SUPERSERVER 6015B-Ni User's Manual 5-11 Floppy, IDE and SATA Drive Connections Note the following when connecting the floppy and hard disk drive cables: • The floppy disk drive cable has seven twisted wires. • A red mark on a wire typically designates the location of pin 1. • A single floppy disk drive ribbon cable has 34 wires and two connectors to provide for two floppy disk drives.
Chapter 5: Advanced Serverboard Setup IDE Connector IDE Drive Connector Pin Definitions (IDE#1) There are no jumpers to con- Pin# Definition figure the onboard IDE#1 con- 1 Reset IDE 2 Ground nector. See the table on the right for pin definitions.
SUPERSERVER 6015B-Ni User's Manual Notes 5-24
Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC812L-520U chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step. Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver.
SUPERSERVER 6015B-Ni Manual Figure 6-1. Chassis: Front and Rear Views Control Panel Drive Bays (behind bezel) Keyboard Port Mouse Port USB Ports 6-2 VGA Port Low Profile PCI Slot Standard PCI Slots COM1 Port Ethernet Ports Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the serverboard to provide you with system status indications. A ribbon cable has bundled these wires together to simplify the connection.
Chapter 6: Advanced Chassis Setup 6-3 System Fans Two 10-cm blower fans provide all the cooling needed for the SuperServer 6015BNi. It is very important that the chassis top cover is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis and cool the components. See Figure 6-2. System Fan Failure If a fan fails, the ambient air temperature in the chassis will rise and activate the overheat LED on the control panel.
SUPERSERVER 6015B-Ni Manual 6-4 Drive Bay Installation/Removal Accessing the Drive Bays To install/remove a disk drive in one of the IDE drive bays, you will need to gain access to the inside of the 6015B-Ni by removing the top cover of the chassis (see Figure 6-3). Figure 6-3.
Chapter 6: Advanced Chassis Setup Figure 6-4. IDE Drive Bay Removal Installing Components in the 3.5" Drive Bays 1. Drive bay configuration The 6015B-Ni has three 3.5" drive bays designed to house hard disk drives. 2. Mounting components in the drive bays First power down the system, remove the AC power cord from the power supply and then remove the top chassis cover to access the drive bays.
SUPERSERVER 6015B-Ni Manual 6-5 Power Supply The SuperServer 6015B-Ni has a single 520 watt power supply, which is autoswitching capable. This enables it to automatically sense and operate with a 100V to 240V input voltage. A power on/off switch is included on the back of the unit. This switch should be turned to the off position before removing the power cord when replacing the unit.
Chapter 6: Advanced Chassis Setup Figure 6-5.
SUPERSERVER 6015B-Ni Manual Notes 6-8
Chapter 7: BIOS Chapter 7 BIOS 7-1 Introduction This chapter describes the Phoenix BIOS™ Setup utility for the X7DBU. The Phoenix ROM BIOS is stored in a flash chip and can be easily upgraded using a floppy disk-based program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the Manual Download area of the Supermicro web site
SUPERSERVER 6015B-Ni User's Manual 7-2 Running Setup Default settings are in bold text unless otherwise noted. The BIOS setup options described in this section are selected by choosing the appropriate text from the main BIOS Setup screen. All displayed text is described in this section, although the screen display is often all you need to understand how to set the options (See the next page). When you first power on the computer, the Phoenix BIOS™ is immediately activated.
Chapter 7: BIOS Main BIOS Setup Menu Main Setup Features System Time To set the system date and time, key in the correct information in the appropriate fields. Then press the key to save the data. System Date Using the arrow keys, highlight the month, day and year fields, and enter the correct data. Press the key to save the data. BIOS Date This field displays the date when this version of BIOS was built.
SUPERSERVER 6015B-Ni User's Manual IDE Channel 0 Master/Slave and Secondary IDE Master/Slave These settings allow the user to set the parameters of IDE Channel 0 Master/Slave and Secondary IDE Master/Slave slots. Press to activate the following submenu screen for detailed options of these items. Set the correct configurations accordingly. The items included in the submenu are: The following items will be displayed in the submenu: Type Selects the type of IDE hard drive.
Chapter 7: BIOS Multi-Sector Transfers This item allows the user to specify the number of sectors per block to be used in multi-sector transfer. The options are Disabled, 4 Sectors, 8 Sectors, and 16 Sectors. LBA Mode Control This item determines whether the Phoenix BIOS will access the IDE Channel 0 Master Device via the LBA mode. The options are Enabled and Disabled. 32 Bit I/O This option allows the user to enable or disable the function of 32-bit data transfer. The options are Enabled and Disabled.
SUPERSERVER 6015B-Ni User's Manual Parallel ATA This setting allows the user to enable or disable the function of Parallel ATA. The options are Enabled and Disabled. Serial ATA This setting allows the user to enable or disable the function of Serial ATA. The options are Disabled and Enabled. Native Mode Operation Select the native mode for ATA. The options are: Serial ATA, and Auto.
Chapter 7: BIOS 7-4 Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. The items with a triangle beside them have submenus that can be accessed by highlighting the item and pressing . Boot Features Access the submenu to make changes to the following settings. QuickBoot Mode If enabled, this feature will speed up the POST (Power On Self Test) routine by skipping certain tests after the computer is turned on.
SUPERSERVER 6015B-Ni User's Manual Power Button Behavior If set to Instant-Off, the system will power off immediately as soon as the user hits the power button. If set to 4-sec., the system will power off when the user presses the power button for 4 seconds or longer. The options are instant-off and 4-sec override. Resume On Modem Ring Select On to “wake your system up” when an incoming call is received by your modem. The options are On and Off.
Chapter 7: BIOS Select Write Protect to prevent data from being written into the base memory area of Block 0-512K. Select Write Back to allow CPU to write data back directly from the buffer without writing data to the System Memory for fast CPU data processing and operation. The options are Uncached, Write Through, Write Protect, and Write Back.
SUPERSERVER 6015B-Ni User's Manual Emulated IRQ Solutions When Enabled, Emulated IRQ Scheme allows PCI devices to run on legacy operating systems that use the MSI mechanism to generate INTX compatible interrupts. The options are Disabled and Enabled. PCI-Exp. I/O Performance Some add-on cards perform faster with the coalesce feature, which limits the payload size to 128 Bytes; while others perform faster with a payload size of 256 Bytes which inhibits coalesce features.
Chapter 7: BIOS Enable Master This setting allows you to enable the selected device as the PCI bus master. The options are Enabled and Disabled. Latency Timer This setting allows you to set the clock rate for Bus Master. A high-priority, highthroughout device may benefit from a greater clock rate. The options are Default, 0020h, 0040h, 0060h, 0080h, 00A0h, 00C0h, and 00E0h. For Unix, Novell and other Operating Systems, please select the option: other.
SUPERSERVER 6015B-Ni User's Manual Branch 1 Rank Interleaving & Sparing Select enable to enable the functions of Memory Interleaving and Memory Sparing for Branch 1 Rank. The options for Memory Interleaving are 1:1, 2:1 and 4:1. The options for Sparing are Enabled and Disabled. Enhanced x8 Detection Select Enabled to enable Enhanced x8 DRAM UC Error Detection. The options are Disabled and Enabled.
Chapter 7: BIOS Enabling Multi-Media Timer Select Yes to activate a set of timers that are alternative to the traditional 8254 timers for the OS use. The options are Yes and No. USB Function Select Enabled to enable the function of USB devices specified. The settings are Enabled and Disabled. Legacy USB Support This setting allows you to enable support for Legacy USB devices. The settings are Enabled and Disabled. Advanced Processor Options Access the submenu to make changes to the following settings.
SUPERSERVER 6015B-Ni User's Manual Adjacent Cache Line Prefetch (Available when supported by the CPU.) The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The CPU fetches both cache lines for 128 bytes as comprised if Enabled. The default settings are Disabled for the Intel 5100 Series Processors and Enable for the 5000 Series Processors. Hardware Prefetcher (Available when supported by the CPU.
Chapter 7: BIOS Interrupt This setting allows you to select the IRQ (interrupt request) for serial port A. The options are IRQ3 and IRQ4. Serial Port B This setting allows you to assign control of serial port B. The options are Enabled (user defined), Disabled, Auto (BIOS controlled) and OS Controlled. Mode This setting allows you to set the type of device that will be connected to serial port B. The options are Normal and IR (for an infrared device).
SUPERSERVER 6015B-Ni User's Manual DMI Event Logging Access the submenu to make changes to the following settings. Event Log Validity This is a display to inform you of the event log validity. It is not a setting. Event Log Capacity This is a display to inform you of the event log capacity. It is not a setting. View DMI Event Log Highlight this item and press to view the contents of the event log. Event Logging This setting allows you to Enable or Disable event logging.
Chapter 7: BIOS Console Redirection Access the submenu to make changes to the following settings. COM Port Address This item allows you to specify which COM port to direct the remote console to: Onboard COM A or Onboard COM B. This setting can also be Disabled. BAUD Rate This item allows you to set the BAUD rate for console redirection. The options are 300, 1200, 2400, 9600, 19.2K, 38.4K, 57.6K, and 115.2K. Console Type This item allows you to set console redirection type.
SUPERSERVER 6015B-Ni User's Manual Hardware Monitor Logic Note: The Phoenix BIOS will automatically detect the type of CPU(s) and hardware monitoring chip used on the motherboard and will display the Hardware Monitoring Screen accordingly. Your Hardware Monitoring Screen may look like the one shown on this page, or on p. 7-19, depending on the type of CPU(s) and HW Monitoring chip you are using.
Chapter 7: BIOS Hardware Monitor Logic (See note on page 7-18.) CPU Temperature Threshold This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold. The hardcode default setting is 75oC.
SUPERSERVER 6015B-Ni User's Manual IPMI (Available only when an IPMI card is installed in the system.) IPMI Specification Version: This item displays the current IPMI Version. Firmware Version: This item displays the current Firmware Version. System Event Logging Select Enabled to enable IPMI Event Logging. When this function is set to Disabled, the system will continue to log events received via system interface. The options are Enabled and Disabled.
Chapter 7: BIOS OS Boot Watch Dog Set to Enabled to enable OS Boot Watch Dog. The options are Enabled and Disabled. Timer for Loading OS (Minutes) This feature allows the user to set the time value (in minutes) for the previous item: OS Boot Watch Dog by keying-in a desired number in the blank. The default setting is 10 (minutes.) (Please ignore this option when OS Boot Watch Dog is set to Disabled.
SUPERSERVER 6015B-Ni User's Manual Realtime Sensor Data This feature display information from motherboard sensors, such as temperatures, fan speeds and voltages of various components.
Chapter 7: BIOS 7-5 Security Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. Security setting options are displayed by highlighting the setting using the arrow keys and pressing . All Security BIOS settings are described in this section. Supervisor Password Is: This feature indicates if a supervisor password has been entered to the system.
SUPERSERVER 6015B-Ni User's Manual Password on Boot This setting allows you to determine if a password is required for a user to enter the system at system boot. The options are Enabled (password required) and Disabled (password not required). 7-6 Boot Choose Boot from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. See details on how to change the order and specs of boot devices in the Item Specific Help window.
Chapter 7: BIOS 7-7 Exit Choose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. All Exit BIOS settings are described in this section. Exit Saving Changes Highlight this item and hit to save any changes you've made and to exit the BIOS Setup utility. Exit Discarding Changes Highlight this item and hit to exit the BIOS Setup utility without saving any changes you may have made.
SUPERSERVER 6015B-Ni User's Manual Notes 7-26
Appendix A: BIOS POST Messages Appendix A BIOS POST Messages During the Power-On Self-Test (POST), the BIOS will check for problems. If a problem is found, the BIOS will activate an alarm or display a message. The following is a list of such BIOS messages. Failure Fixed Disk Fixed disk is not working or not configured properly. Check to see if fixed disk is attached properly. Run Setup. Find out if the fixed-disk type is correctly identified. Stuck key Stuck key on keyboard.
SUPERSERVER 6015B-Ni User's Manual System CMOS checksum bad - Default configuration used System CMOS has been corrupted or modified incorrectly, perhaps by an application program that changes data stored in CMOS. The BIOS installed Default Setup Values. If you do not want these values, enter Setup and enter your own values. If the error persists, check the system battery or contact your dealer. System timer error The timer test failed. Requires repair of system board.
Appendix A: BIOS POST Messages System cache error - Cache disabled RAM cache failed and BIOS disabled the cache. On older boards, check the cache jumpers. You may have to replace the cache. See your dealer. A disabled cache slows system performance considerably. CPU ID: CPU socket number for Multi-Processor error. EISA CMOS not writeable ServerBIOS2 test error: Cannot write to EISA CMOS. DMA Test Failed ServerBIOS2 test error: Cannot write to extended DMA (Direct Memory Access) registers.
SUPERSERVER 6015B-Ni User's Manual Fixed Disk n Fixed disk n (0-3) identified. Invalid System Configuration Data Problem with NVRAM (CMOS) data. I/O device IRQ conflict I/O device IRQ conflict error. PS/2 Mouse Boot Summary Screen: PS/2 Mouse installed. nnnn kB Extended RAM Passed Where nnnn is the amount of RAM in kilobytes successfully tested. nnnn Cache SRAM Passed Where nnnn is the amount of system cache in kilobytes successfully tested.
Appendix A: BIOS POST Messages Press to resume, to Setup, for previous Displayed after any recoverable error message. Press to start the boot process or to enter Setup and change the settings. Press to display the previous screen (usually an initialization error of an Option ROM, i.e., an add-on card). Write down and follow the information shown on the screen. Press to enter Setup Optional message displayed during POST. Can be turned off in Setup.
SUPERSERVER 6015B-Ni User's Manual Notes A-6
Appendix B: BIOS POST Codes Appendix B BIOS POST Codes This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are divided into two categories: recoverable and terminal. Recoverable POST Errors When a recoverable type of error occurs during POST, the BIOS will display an POST code that describes the problem.
SUPERSERVER 6015B-Ni User's Manual POST Code Description 18h 1Ah 1Ch 20h 22h 24h 28h 29h 2Ah 2Ch 2Eh 2Fh 32h 33h 36h 38h 3Ah 3Ch 3Dh 41h 42h 45h 46h 48h 49h 4Ah 4Bh 4Ch 4Eh 4Fh 50h 51h 52h 54h 55h 58h 59h 5Ah 5Bh 8254 timer initialization 8237 DMA controller initialization Reset Programmable Interrupt Controller 1-3-1-1 Test DRAM refresh 1-3-1-3 Test 8742 Keyboard Controller Set ES segment register to 4 GB Auto size DRAM Initialize POST Memory Manager Clear 512 kB base RAM 1-3-4-1 RAM failure on address li
Appendix B: BIOS POST Codes POST Code Description 5Ch 60h 62h 64h 66h 67h 68h 69h 6Ah 6Bh 6Ch 70h 72h 76h 7Ch 7Dh 7Eh 80h 81h 82h 83h 84h 85h 86h 87h 88h 89h 8Ah 8Bh 8Ch 8Fh 90h 91h 92h 93h 95h 96h 97h 98h Test RAM between 512 and 640 kB Test extended memory Test extended memory address lines Jump to UserPatch1 Configure advanced cache registers Initialize Multi Processor APIC Enable external and CPU caches Setup System Management Mode (SMM) area Display external L2 cache size Load custom defaults (optiona
SUPERSERVER 6015B-Ni User's Manual POST Code Description 99h 9Ch 9Dh 9Eh 9Fh A0h A2h A4h A8h AAh ACh AEh B0h B1h B2h B4h B5h B6h B7h B9h BAh BCh BDh BEh BFh C0h C1h C2h C3h C4h C6h C7h C8h C9h CDh Check for SMART Drive (optional) Set up Power Management Initialize security engine (optional) Enable hardware interrupts Determine number of ATA and SCSI drives Set time of day Check key lock Initialize typematic rate Erase prompt Scan for key stroke Enter SETUP Clear Boot flag Check for errors Inform
Appendix B: BIOS POST Codes POST Code Description D2h D4h D8h D9h DEh Unknown interrupt Check Intel Branding string Alert Standard Format initialization Late init for IPMI Log error if micro-code not updated properly The following are for boot block in Flash ROM POST Code E0h E1h E2h E3h E4h E5h E6h E7h E8h E9h EAh EBh ECh EDh EEh EFh F0h F1h F2h F3h F4h F5h F6h F7h Description Initialize the chipset Initialize the bridge Initialize the CPU Initialize system timer Initialize system I/O Check force recov
SUPERSERVER 6015B-Ni User's Manual Notes B-6
Appendix C: Software Installation Appendix C Software Installation After all the hardware has been installed, you must first configure Intel's ESB2 SATA RAID before you install the Windows Operating System and other software drivers. Important Notes: If you do not wish to configure onboard SATA RAID functions, please go directly to Section C-3. This chapter describes RAID Configuration Instructions for the Intel ESB2 RAID Controller designed for Windows OS.
SUPERSERVER 6015B-Ni User's Manual RAID Configurations The following types of RAID configurations are supported: RAID 0 (Data Striping): this writes data in parallel, interleaved ("striped") sections of two hard drives. Data transfer rate is doubled over using a single disk. RAID1 (Data Mirroring): an identical data image from one drive is copied to another drive. The second drive must be the same size or larger than the first drive.
Appendix C: Software Installation Using the Intel ESB2 SATA RAID Utility Program 1. Creating, Deleting and Resetting RAID Volumes a. After the system exits from the BIOS Setup Utility, it will automatically reboot. The following screen appears after the Power-On Self Test. b. When you see the above screen, press the and the keys simultaneously to have the main menu of the SATA RAID Utility appear: Note: All graphics and screen shots shown in this manual are for reference only.
SUPERSERVER 6015B-Ni User's Manual Creating a RAID 0 Volume a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 0 set and press the key or the key to go to the next field. (You can use the key to select the previous menu.) c. When RAID Level item is highlighted, press the , keys to select RAID 0 (Stripe) and hit . d.
Appendix C: Software Installation Creating a RAID 1 Volume a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 1 set and press the key or the key to go to the next field. (You can use the key to select the previous menu.) c. When RAID Level item is highlighted, press the , keys to select RAID 1 (Mirror) and hit . d.
SUPERSERVER 6015B-Ni User's Manual Creating a RAID 10 (RAID 1+ RAID 0) a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 10 set and press . c. When RAID Level item is highlighted, use the , keys to select RAID 10 (RAID1 + RAID0) and hit . d.
Appendix C: Software Installation Creating a RAID 5 Set (Parity) a. Select "Create RAID Volume" from the main menu and press the key. The following screen will appear: b. Specify a name for the RAID 5 set and press . c. When the Raid Level is highlighted, use the , keys to select RAID 5 (Parity) and hit . d. When the Disk item is highlighted, press to select the HDD to configure as RAID. e.
SUPERSERVER 6015B-Ni User's Manual Deleting a RAID Volume Warning! Be sure to back up your data before deleting a RAID set. You ! will lose all data on the disk drives when deleting a RAID set. a. From the main menu, select item2-Delete RAID Volume, and press . b. Use the , keys to select the RAID set you want to delete and press . A Warning message displays. c.
Appendix C: Software Installation Resetting to Non-RAID and Resetting a RAID HDD Warning! Use cautious when resetting a RAID volume HDD to non- ! RAID or resetting a RAID HDD. Resetting a RAID volume HDD or resetting a RAID HDD will reformat the HDD and delete the internal RAID structure on the drive. a. From the main menu, select item3-Reset Disks to Non- RAID, and press . The following screen will appear: b.
SUPERSERVER 6015B-Ni User's Manual C-2 Installing Windows XP/2000/2003 for RAID Systems New Operating System-Windows XP/2000/2003 Installation a. Insert the Microsoft Windows XP/2000/2003 Setup CD in the CD Drive and the system will start booting up from CD. b. Press the key when the message" Press F6 if you need to install a third party SCSI or RAID driver" displays. c. When the Windows XP/2000/2003 setup screen appears, press "S" to specify additional device(s). d.
Appendix C: Software Installation C-3 Installing the Operating System and other Software Programs After the hardware has been installed, you must first install the operating system, and then, other software drivers. The necessary drivers are all included on the Supermicro CDs that came packaged with your motherboard. Driver/Tool Installation Display Screen Note: Click the icons showing a hand writing on paper to view the readme files for each item.
SUPERSERVER 6015B-Ni User's Manual Supero Doctor III The Supero Doctor III program is a Web base management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system.
Appendix C: Software Installation Supero Doctor III Interface Display Screen-II (Remote Control) Note: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp:// ftp.supermicro.com/utility/Supero_Doctor_III/. You can also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend Supero Doctor II.
SUPERSERVER 6015B-Ni User's Manual Notes C-14
Appendix D: System Specifications Appendix D System Specifications Processors Single or dual Intel® Xeon™ 5300/5100/5000 Sequence processors at a front side (system) bus speed of 1333/1066/667 MHz. Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel 5000P/ESB2 chipset BIOS 8 Mb Phoenix® Flash ROM Memory Capacity Eight 240-pin DIMM sockets supporting up to 32 GB of ECC FBD DDR2-667/533 SDRAM. See the memory section in Chapter 5 for details.
SUPERSERVER 6015B-Ni User's Manual Weight Gross (Bare Bone): 33 lbs. (15 kg.) System Cooling Two (2) 10-cm blower fans System Input Requirements AC Input Voltage: 100-240 VAC Rated Input Current: 7A (115V) to 3A (230V) Rated Input Frequency: 50-60 Hz Power Supply Rated Output Power: 520W (Model# PWS-521-1H20) Rated Output Voltages: +5V (20A), +12V (39A), -12V (0.5A), +3.3V (16A), +5Vsb (3.