SDS
Page 8 of 13
Safety Data Sheet
acc. to OSHA HCS (29 CFR 1910.1200)
Revision: June 18, 2015
Trade name: Super Lube® Syncopen® Synthetic Penetrant Aerosol
(Contd. of page 7)
40.1.3
·
Decomposition temperature:
Not determined.
·
Auto igniting:
Product is not self-igniting.
·
Danger of explosion:
Not determined.
·
Explosion limits:
Lower:
1.1 Vol %
Upper:
7 Vol %
·
Vapor pressure:
Not determined.
·
Density:
Not determined.
·
Relative density
Not determined.
·
Vapour density
Not determined.
·
Evaporation rate
Not applicable.
·
Solubility in / Miscibility with
Water:
Not miscible or difficult to mix.
·
Partition coefficient (n-octanol/water):
Not determined.
·
Viscosity:
Dynamic:
Not determined.
Kinematic:
Not determined.
·
Solvent content:
VOC (California)
< 25%
Exempt VOCs are excluded from this value
·
Other information
No further relevant information available.
10 Stability and reactivity
·
Reactivity
·
Chemical stability
·
Thermal decomposition / conditions to be avoided:
Danger of receptacles bursting because of high vapor pressure if heated.
·
Possibility of hazardous reactions
Develops readily flammable gases / fumes.
Can form explosive mixtures in air if heated above flash point and/or when sprayed or atomized.
Extremely flammable aerosol.
Used empty containers may contain product gases which form explosive mixtures with air.
Reacts with strong oxidizing agents.
Toxic fumes may be released if heated above the decomposition point.
·
Conditions to avoid
Keep ignition sources away - Do not smoke.
Keep away from heat and direct sunlight.
Store away from oxidizing agents.
·
Incompatible materials:
No further relevant information available.
·
Hazardous decomposition products:
Carbon monoxide and carbon dioxide
(Contd. on page 9)