SDS
Page 7 of 13
Safety Data Sheet
acc. to OSHA HCS (29 CFR 1910.1200)
Revision: June 18, 2015
Trade name: Super Lube® Syncopen® Synthetic Penetrant Aerosol
(Contd. of page 6)
40.1.3
·
Breathing equipment:
Not required under normal conditions of use.
Use suitable respiratory protective device in case of insufficient ventilation.
Use suitable respiratory protective device when high concentrations are present.
For spills, respiratory protection may be advisable.
·
Protection of hands:
Protective gloves
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the
degradation
·
Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of
quality and varies from manufacturer to manufacturer. As the product is a preparation of several
substances, the resistance of the glove material can not be calculated in advance and has therefore to be
checked prior to the application.
·
Penetration time of glove material
The exact break through time has to be found out by the manufacturer of the protective gloves and has to
be observed.
·
Eye protection:
Safety glasses
·
Body protection:
Protective work clothing
·
Limitation and supervision of exposure into the environment
No further relevant information available.
9 Physical and chemical properties
·
Information on basic physical and chemical properties
·
General Information
·
Appearance:
Form:
Aerosol
Color:
Translucent
·
Odor:
Solvent-like
·
Odor threshold:
Not determined.
·
pH-value:
Not determined.
·
Change in condition
Melting point/Melting range:
Not applicable, as aerosol.
Boiling point/Boiling range:
Not applicable, as aerosol.
·
Flash point:
Extremely flammable aerosol.
·
Flammability (solid, gaseous):
Extremely flammable aerosol.
·
Auto-ignition temperature:
210 °C (410 °F)
(Contd. on page 8)