SDS

SAFETY DATA SHEET
Date Prepared : 02/27/2017
MSDS No :
Date-Revised : 08/10/2017
Revision No : 2
BOILING POINT: 74°C (165.2°F) to 7C (168.8°F)
FREEZING POINT: No data available
MELTING POINT: No data available
POUR POINT: No data available
THERMAL DECOMPOSITION: No data available
SOLUBILITY IN WATER: Polymerizes in presence of water
PARTITION COEFFICIENT: N-OCTANOL/WATER: No data available
EVAPORATION RATE: No data available
DENSITY: No data available
SPECIFIC GRAVITY: 1.19
VISCOSITY #1: 180 to 220 at 2C (77°F)
MOLECULAR WEIGHT: No data available
(VOC): < 3 %
10. STABILITY AND REACTIVITY
REACTIVITY: Rapid exothermic polymerization will occur in presence of incompatible materials.
HAZARDOUS POLYMERIZATION: Polymerization will occur on contact with water, amines, alkali, and alcohols. The
polymerization is an exothermic reaction and may cause thermal burns.
STABILITY: Stable under normal storage and handling conditions.
CONDITIONS TO AVOID: Keep away from heat, flames, and other sources of ignition. Keep dry. Avoid high humidity or high
temperatures above 80C/176F.
POSSIBILITY OF HAZARDOUS REACTIONS: Possible polymerization reaction in the presence of water, amines, alkalis and
alcohols.
HAZARDOUS DECOMPOSITION PRODUCTS: Thermal decomposition will produce oxides of carbon and nitrogen, and other
toxic or irritating compounds.
INCOMPATIBLE MATERIALS: Water, alcohol, amines, and alkaline materials.
11. TOXICOLOGICAL INFORMATION
ACUTE TOXICITY
Chemical Name ORAL LD
50
(rat) DERMAL LD
50
(rabbit)
2-Methoxyethyl 2-cyanoacrylate > 5000 mg/kg > 2000 mg/kg
Hydroquinone 367.3 mg/kg > 2000 mg/kg
RESPIRATORY OR SKIN SENSITISATION: No data available for the mixture. Testing for skin sensitization is technically not
feasible. The adhesive bonds instantaneous to the surface of the skin and polymerizes. The polymerized material is not able to
penetrate into the epidermis.
GERM CELL MUTAGENICITY: Hydroquinone: Positive with metabolic activation and negative without metabolic activation in an
In-vitro mammalian chromosome aberration test. Positive in mammalian germ cell cytogenetic assay.
CARCINOGENICITY
Page 4 of 6
Light Curing Adhesive