SDS

SAFETY DATA SHEET
Date Prepared : 02/27/2017
MSDS No :
Date-Revised : 08/10/2017
Revision No : 2
thoroughly after handling. Keep away from flames and sources of ignition. No smoking in storage or use areas. Keep containers
closed when not in use.
STORAGE: Store in a container in a cool, dry, well-ventilated location away from heat, sunlight and incompatible materials. Keep
in original container. Prevent moisture contact. Keep container tightly closed when not in use.
STORAGE TEMPERATURE:C (35.6°F) Minimum to 8°C (46.4°F) Maximum
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
EXPOSURE GUIDELINES
OSHA HAZARDOUS COMPONENTS (29 CFR1910.1200)
EXPOSURE LIMITS
Chemical Name Type ppm mg/m
3
2-Methoxyethyl 2-cyanoacrylate Supplier OEL TWA 0.2
Hydroquinone
ACGIH TLV TLV (DSEN) 1
OSHA PEL TWA 2
ENGINEERING CONTROLS: Use with adequate general or local exhaust ventilation to minimize exposure levels.
PERSONAL PROTECTIVE EQUIPMENT
EYES AND FACE: Chemical safety goggles are recommended where splashing is possible.
SKIN: Impervious gloves such as nitrile gloves are suggested to prevent skin contact. Do not use PVC, Nylon, or cotton
materials. Contact your glove supplier for selection assistance.
RESPIRATORY: If needed, an approved respirator with organic vapor cartridges may be used. For higher exposures, a
supplied air respirator may be required. Respirator selection and use should be based on contaminant type, form, and
concentration. Follow applicable regulations and good Industrial Hygiene practice.
OTHER USE PRECAUTIONS: Impervious clothing is required to prevent skin contact and contamination of personal clothing. An
eye wash facility and safety shower should be available in the work area.
9. PHYSICAL AND CHEMICAL PROPERTIES
PHYSICAL STATE: Liquid
ODOR: Odorless
ODOR THRESHOLD: No data available
APPEARANCE: Transparent liquid
COLOR: Yellow to light green.
pH: No data available
PERCENT VOLATILE: No data available
FLASHPOINT AND METHOD: 80°C (176°F) to 93.3°C (199.94°F)
FLAMMABLE LIMITS: No data available
AUTOIGNITION TEMPERATURE: No data available
VAPOR PRESSURE: No data available
VAPOR DENSITY: No data available
Page 3 of 6