Safety Data Guide
Page 6/12
Safety Data Sheet
according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and
GHS
Printing date 07.11.2013 Revision: 07.11.2013
Trade name: SUPCO 88
(Contd. of page 5)
37.1.11
·
8.1 Control parameters
·
Ingredients with limit values that require monitoring at the workplace:
64742-81-0 Kerosine (petroleum), hydrodesulfurized
REL (USA) Long-term value: 100 mg/m³
Kerosene only
TLV (USA) Long-term value: 200 mg/m³
as total hydrocarbon vapor; Skin; P
EV (Canada) Long-term value: 200(G) mg/m³
as total hydrocarbon vapour, Skin
·
DNELs
No further relevant information available.
·
PNECs
No further relevant information available.
·
Additional information:
The lists valid during the making were used as basis.
·
8.2 Exposure controls
·
Personal protective equipment:
·
General protective and hygienic measures:
The usual precautionary measures are to be adhered to when handling chemicals.
Keep away from foodstuffs, beverages and feed.
Wash hands before breaks and at the end of work.
Do not inhale gases / fumes / aerosols.
Avoid contact with the eyes and skin.
·
Respiratory protection:
Use suitable respiratory protective device in case of insufficient ventilation.
Use suitable respiratory protective device when aerosol or mist is formed.
For spills, respiratory protection may be advisable.
NIOSH approved organic vapor respirator equipped with a dust/mist prefilter should be used.
·
Protection of hands:
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.
Selection of the glove material on consideration of the penetration times, rates of diffusion and the
degradation.
·
Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of
quality and varies from manufacturer to manufacturer. As the product is a preparation of several
substances, the resistance of the glove material can not be calculated in advance and has therefore to be
checked prior to the application.
·
Penetration time of glove material
The exact break through time has to be found out by the manufacturer of the protective gloves and has to
be observed.
·
For the permanent contact gloves made of the following materials are suitable:
Butyl rubber, BR
Nitrile rubber, NBR
Neoprene gloves
·
Eye protection:
Safety glasses
(Contd. on page 7)