Safety Data Guide
Page 5/12
Safety Data Sheet
according to 1907/2006/EC (REACH), 1272/2008/EC (CLP), and
GHS
Printing date 30.10.2012 Revision: 30.10.2012
Trade name: LEAK LOCK
(Contd. of page 4)
35.0.37
7
Handling and storage
·
7.1 Precautions for safe handling
Ensure good ventilation/exhaustion at the workplace.
Prevent formation of aerosols.
·
Information about fire - and explosion protection:
Keep ignition sources away - Do not smoke.
Protect against electrostatic charges.
Flammable gas-air mixtures may form in empty receptacles.
·
7.2 Conditions for safe storage, including any incompatibilities
·
Storage:
·
Requirements to be met by storerooms and receptacles:
Store in a cool location.
Provide ventilation for receptacles.
·
Information about storage in one common storage facility:
Store away from foodstuffs.
Store away from oxidizing agents.
·
Further information about storage conditions:
Store in cool, dry conditions in well sealed receptacles.
Keep container tightly sealed.
Store receptacle in a well ventilated area.
·
7.3 Specific end use(s)
No further relevant information available.
8
Exposure controls/personal protection
·
Additional information about design of technical facilities:
No further data; see item 7.
·
8.1 Control parameters
·
Ingredients with limit values that require monitoring at the workplace:
64-17-5 ethanol
PEL (USA) 1900 mg/m³, 1000 ppm
REL (USA) 1900 mg/m³, 1000 ppm
TLV (USA) Short-term value: 1880 mg/m³, 1000 ppm
EL (Canada) Short-term value: 1000 ppm
EV (Canada) 1,900 mg/m³, 1,000 ppm
57-55-6 Propylene Glycol
WEEL (USA) 10 mg/m³
EV (Canada) 155* 10** mg/m³, 50* ppm
*vapour and aerosol;**aerosol only
·
DNELs
No further relevant information available.
·
PNECs
No further relevant information available.
·
Additional information:
The lists valid during the making were used as basis.
(Contd. on page 6)