OPERATIONS:
Transmitter:
General:
The RCB04A Remote Control has two (2) operating modes: Manual and Thermostatic. The control system can be
set to temperature ranges between 45°F and 99°F.
The transmitter will operate the remote receiver from 1 foot to 30 feet. The distance is reduced when batteries are
low or when the receiver is inside a metal enclosure.
Initial start up:
1. After initial power up the transmitter is reset.
2. During system reset, all features of the LCD will be visible. After one second, the LCD
will be initialized. A typical reset display is shown right. After reset the transmitter is
operating. The real room temperature is shown as right.
Manual Mode:
1. Press the” ON” button once to turn on the appliance.
2. Press the” OFF” button once again to turn off the appliance.
3. Press” ON” andOFF” button at same time for 1 second to select between °C and °F display.
Thermostatic mode:
1. Press the ”MODE” button to enter the thermostatic mode. ROOM and TEMP icon
will appear on the lower LCD screen
2. In thermostatic mode, press and hold the ”SET button to set the desired set
temperature between 45°F and 9F.
3. Once the setting is completed, the transmitter will automatically turn on the fireplace
when the room temperature is below the set temperature and turn off the appliance
when the room temperature is above the set temperature within 1 degree.
4. There will be a slight delay in the response of the unit (on/off) to a temperature.
Room temperature is monitored every 3 minutes.
5. Press theON” button or”OFF”button or”MODE”button to exit the thermostatic mode
(Return to Manual Mode). The “ROOM” temp icon will disappear on the lower LCD
display. The transmitter will be in the manual on/off mode
Low-battery detection:
1. When the battery voltage of remote less than 2.2V, the low battery icon will appear on
the LCD screen. The battery will be checked every3 minute. If the battery voltage of
remote is less than 1.5V, the remote will send the flame off command to the receiver and
only low battery icon display on the LCD,
Change the battery before the battery is too weak for normal operation. TURN THE
UNIT OFF BEFORE REPLACING BATTERIES.
Child-proof protection:
1. Press and hold ”ON” and”MODE” button at same time for 5 seconds to activate child-
proof mode. The letters CP will appear in the TEMP frame on the LCD screen.