User's Manual
CrossFire – A revolution in RF Transport for In Building Wireless
User Manual
77 Revision 1.0.1
Connection & Query Status
Alarm Parameter Configuration
Completion
Figure 7-2 EU Debugging Procedures
7.1. Network Management System Setup for SNMP
The site number must be set using the WebOMT on the Master AU before connecting to the network management
system (NMS). The NMS should identify devices by their unique site number. Network parameters also need to be set up
for the specific network. If the NMS supports the SNMP protocol, set Protocol Select to “SNMP” and configure related
parameters such as the Trap IP Addr, Trap Port, Subnet Mask, Default Gateway, etc. as shown in Table 7. If the NMS
supports the ZENIC8 proprietary protocol, set Protocol Select to “TCP/IP” and configure the corresponding parameters
as shown in Table 6.
The remote FTP server parameters also need to be set up if remote software upgrades are supported. These
parameters are set in the Engineering tab ―> User Para sub-tab in the WebOMT. See Figure 7-3 for details.