6.4.2. NPRU Alarms
Parameter
Description
RD/RW
Movement Alarm
Alarm when device leave the original installation location
RW
Over-temperature Alarm
Alarm when device temperature over rated temperature
threshold
RW
LO1~4 unlocked Alarm
Local Oscillation unlocked
RW
Module1~4 ALC Alarm
Alarm when ALC is working
RW
ANT 1~2 DL Under Output-power
Alarm
ANT 1~2 output-power under rated threshold
RW
ANT 1~2 DL Over Output-power
Alarm
ANT 1~2 output-power over rated threshold
RW
Link Alarm
Alarm when local NPRU cannot connect to the system
RW
Table 6-4 CrossFire Alarms for the NPRU
Parameter
Description
RD/RW
ANT 1~2 DL Under Output-power
Threshold
Alarm when device leave the original installation location
RW
ANT 1~2 DL Over Output-power
Threshold
Local Oscillation unlocked
RW
Over-temperature Threshold
Default value:85℃/ Range: -55~ +125℃
RW
Table 6-5 Alarm Thresholds
6.4.3. NPRU System Information
Parameter
Description
RD/RW
Filter Bandwidth
/
RD
UL Carrier Centre Frequency
/
RD
DL Carrier Centre Frequency
/
RD
UL Input-power
/
RD
Module State
/
RD
Table 6-6 Module 1~4
Parameter
Description
RD/RW
ANT1~2
/
RD
Table 6-7 DL Output-power
Parameter
Description
RD/RW
Device Temperature
/
RD
Device Routing Address
/
RD
Table 6-8 General