Parameter
Description
RD/RW
Maximum Delay
Maximum delay from AU to the last NPRU
RD
Table 4-22 Digital Panel Information
Parameter
Description
RD/RW
OP1~6 CPRI Sync Alarm
CPRI SYNC alarm for Port “ OP1~OP6
RD
OP-AU1~2 CPRI Sync Alarm
CPRI SYNC alarm for Port AU1/2
RD
OP1~6LOS Alarm
Loss of optical signal alarm for Port “OP1~OP6
RD
OP-AU1~2 LOS Alarm
Loss of optical signal alarm for Port “AU1/2
RD
Table 4-23 OP Info
Command
Description
RD/RW
Master / Slave AU Select
Master AU / Slave AU select
RW
Backup Battery Switch
Enable/Disable backup battery mode
RW
Battery Contain
/
RW
Hardware Reset
Note: Signal is interrupted during hardware reset
RW
Software Reset
Note: Signal is normal during software reset
RW
Alarm Initialization
Initialization: Clear alarms and disable all alarms;
Report Site launch: Report to OMC when new site launches;
RW
Alarm Mode Select
Normal mode: 3 minutes
Test mode: 1 minute
RW
Table 4-24 Advanced Commands
Parameter
Description
RD/RW
Up-Downlink Switch
Switch for TDD test
RW
Table 4-25 Test Mode
Parameter
Description
RD/RW
Up-Downlink Switch
Switch for TDD test
RW
Isolation ANT Switch
Tx1 or Tx2
RW
Detecting Frequency
/
RW
Isolation Detector Switch
Turn on/off Isolation Detector
RW
Table 4-26 Test Mode
4.7.8. AU Factory Command
Parameter
Description
RD/RW
Factory Mode
Access to Factory Mode with authority
RW
Factory Mode Password
Reserve
RW
Table 4-27 AU Factory Parameters