User's Manual

CrossFire iDAS All-Digital Transport System
User Guide
© SUNWAVE SOLUTIONS LIMITED 2017 28 Version 1.0
Parameter
Description
RD/RW
Default Gateway
Default Gateway 10.7.0.1
RW
Device Port (UDP)
Device port number for UDP
RW
Heartbeat Interval Time
Interval time of device sending packet to OMC, to confirm a
free link
RW
Table 4-6 IP Settings
Parameter
Description
RD/RW
Server IP Addr (FTP)
IP Address of the connected FTP Server for software upgrade
RW
Server port (FTP)
Port Number of the connected FTP Server for software
upgrade
RW
FTP Username
Username for device to log into FTP Server
RW
FTP Password
Password for device to log into FTP Server
RW
Upgrade Filepath
File path (directory) for device to acquire software upgrade file
from FTP Server
RW
Upgrade Filename
Filename of the awaiting software upgrade file
RW
Date and Time
/
RW
Site Report
/
RW
Table 4-7 FTP Settings
4.7.2. AU Alarms
Table 4-8 lists the possible alarms on the CrossFire system for the AU.
Table 4-8 CrossFire Alarms for the AU
Parameter
Description
RD/RW
Power Interruption Alarm
Electrical supply failure
RD
Battery Failure Alarm
Standby battery failure
RD
Movement Alarm
Device has been moved from the original installation location
RD
Open Case Alarm
Alarm when device is open
RD
Over-temperature Alarm
Device temperature is over the rated temperature threshold
RD
LO1~4 Unlocked Alarm
Local oscillation unlocked
RD
Module1~4 ALC Alarm
Alarm when ALC is working
RD
OP1~6 Transceiver Failure Alarm
OP-transceiver unplugged or failure (Port OP1~OP6)
RD
OP-AU1/2 Transceiver Failure
Alarm
OP-transceiver unplugged or failure (Port S_AU1/2)
RD
External Alarm 1~4
External device failure (such as UPS failure)
RD
Module 1~4 Port1~4 DL Under
Input-power Alarm
Module 1~4 Port1~4 input power under rated threshold
RD
Module 1~4 Port1~4 DL Over
Input-power Alarm
Module 1~4 Port1~4 input power over rated threshold
RD